← Back
BuildNYC
Miscellaneous two family
133 KANE STREET
BROOKLYN · BIN 3003491
💬 Discuss this project
1840Year Built
3Stories
B9Building Class
R6Zoning
2,688 sfGross Floor Area
2Units
0 Active Violations 1 likely answered ▸FDNY Report ↗
Miscellaneous two family · 1,974 sf lot · 1.36 FAR built · Flood zone X500
Locations of Work
Structural
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
CellarBasement and cellar framing6p · 1 filing · 20 docs
BasementBasement and cellar framing1p · 1 filing · 20 docs
Sub-BasementBasement and cellar framing5p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Silman311/18/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Permitwise603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Dominick Siano G'NL ContGeneral Contractor307/08/2026
John Hlad P & H CoPlumbing303/22/2026
Antonio Ceriello ElectricElectrical203/21/2026
WCK ElectricElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Triangle Inspection & Tes7495311/18/2020
Building Lifecycle
06/22/2021
Closed: The DOB hereby orders you to stop all work under job #321917681 due to suspension of filing privileges of applicant
DOB violation · closed on the city's record
06/21/2021
Signed off — Alteration
STRUCTURAL WORK FILED IN CONJUNCTION WITH BIS JOB 340685636. STRUCTURAL WORK AT BASEMENT AND CELLAR LEVELS.
B00205586-I1
05/11/2021
Special inspection requirement — Structural Steel - Details
RAJASEKHA SAKHAMURI
03/30/2021
Special inspection requirement — Structural Steel - High Strength Bolting
RAJASEKHA SAKHAMURI
03/30/2021
Special inspection requirement — Post-installed Anchors
RAJASEKHA SAKHAMURI
21 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offDominick Siano G'NL Cont10/02/2020
DOB NOWStructuralSigned-offDominick Siano G'NL Cont12/11/2019
BISPLISSUEDJohn Hlad P & H Co11/18/2020
BISOTISSUEDDominick Siano G'NL Cont10/01/2020
BISOTISSUEDPalone Brothers Air05/21/2020
BISOTISSUEDDominick Siano G'NL Cont12/11/2019
BISOTISSUEDPalone Brothers Air08/28/2019
BISEQISSUEDB H & B Construction06/03/2014
BISEQISSUEDB H & B Construction04/01/2014
2 projects · most recent 11/24/2020
General Wiring
FiledStatusContractorScope
11/24/2020CompleteAntonio Ceriello ElectricGeneral Wiring
10/21/2020CompleteAntonio Ceriello Electric—
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
05/11/2021Structural Steel - DetailsRAJASEKHA SAKHAMURIspecial
03/30/2021Structural Steel - High Strength BoltingRAJASEKHA SAKHAMURIspecial
03/30/2021Post-installed AnchorsRAJASEKHA SAKHAMURIspecial
03/30/2021Structural Stability – Alterations of existing buildingsRAJASEKHA SAKHAMURIspecial
03/30/2021FinalRAJASEKHA SAKHAMURIprogress
03/30/2021Structural Wood FrameRAJASEKHA SAKHAMURIprogress
03/05/2021Structural Steel - Details—special
11/16/2020Post-installed AnchorsRAJASEKHA SAKHAMURIspecial
11/16/2020Structural Stability – Alterations of existing buildingsRAJASEKHA SAKHAMURIspecial
11/16/2020Structural Steel - High Strength BoltingRAJASEKHA SAKHAMURIspecial
11/16/2020FinalRAJASEKHA SAKHAMURIprogress
11/16/2020Structural Wood FrameRAJASEKHA SAKHAMURIprogress
119 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account