← Back
Two family frame
135 ARLINGTON AVENUE
STATEN ISLAND · Mariner's Harbor-Arlington-Graniteville · BIN 5028433
💬 Discuss this project
1915Year Built
2Stories
B2Building Class
R3XZoning
3,622 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · Owner of record: 135 ARLINGTON LLC · 7,250 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction21p · 1 filing · 20 docs
Floor 2Under Construction21p · 2 filings · 20 docs
Floor 1Under Construction22p · 2 filings · 20 docs
CellarUnder Construction21p · 1 filing · 20 docs
Sub-Basement23p · 3 filings · 20 docs
Site & exteriorUnder Construction3p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MENDEZ BROS CONSTRUCTION CORP4809/13/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NODE ARCHITECTURE,ENGINEERING, CONS1307/31/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NODE ENGINEERING CONSULTING1403/21/2026
NODE ARCHITECTURE,ENGINEERING,CON1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NODE SYSTEMS AND ASSEMBLIGeneral Contractor2407/08/2026
MONTANA COOLING & HEATINGGeneral Contractor304/09/2026
IPS PLUMBING CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
INTERNATIONAL GEOTEHCNICA1795807/31/2026
NODE ARCHITECTURE,ENGINEE6799907/31/2026
Building Lifecycle
All (70)Filed (13)Permit Issued (15)Signed Off (4)Violation (2)Inspection (6)Special Inspection (30)
07/31/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
New Plumbing System filed in conjunction with Alt1 application #S00961961-I1
S00961961-P3
06/09/2026
Special inspection requirement — Energy Code Compliance Inspections
Radomir Delic
06/09/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
MICHAEL KARANTINIDIS, P.E.
06/09/2026
Special inspection requirement — Maintenance information
MICHAEL KARANTINIDIS, P.E.
06/09/2026
Special inspection requirement — HVAC-R and service water heating equipment
MICHAEL KARANTINIDIS, P.E.
06/09/2026
Special inspection requirement — Permanent certificate
MICHAEL KARANTINIDIS, P.E.
06/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Radomir Delic
06/09/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
MICHAEL KARANTINIDIS, P.E.
06/09/2026
Special inspection requirement — HVAC-R and service water heating system controls
MICHAEL KARANTINIDIS, P.E.
03/24/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/21/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/20/2026
Permit issued — General Construction
S00961961-I1-GC-CX
12/12/2025
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
11/28/2025
Permit issued — Plumbing
S00961961-S2-PL
11/12/2025
Permit issued — Structural
S00961961-I1-GC-CX
11/12/2025
Permit issued — Construction Fence
S00955797-I1-FN
10/23/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
New Plumbing System filed in conjunction with Alt1 application #S00961961-I1
S00961961-P2
10/15/2025
Special inspection requirement — Energy Code Compliance Inspections
Radomir Delic
10/15/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
MICHAEL KARANTINIDIS, P.E.
10/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Radomir Delic
10/15/2025
Special inspection requirement — HVAC-R and service water heating equipment
MICHAEL KARANTINIDIS, P.E.
10/15/2025
Special inspection requirement — HVAC-R and service water heating system controls
MICHAEL KARANTINIDIS, P.E.
10/15/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
MICHAEL KARANTINIDIS, P.E.
10/15/2025
Special inspection requirement — Maintenance information
Radomir Delic
10/15/2025
Special inspection requirement — Permanent certificate
Radomir Delic
09/17/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
09/17/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/01/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
New Plumbing System filed in conjunction with Alt1 application #S00961961-I1
S00961961-P1
06/17/2025
Signed off — Alteration
Foundation work application
S01015121-I1
06/16/2025
Signed off — Alteration
S01013122-I1
06/12/2025
Signed off — Alteration
S00994496-I1
06/12/2025
Signed off — Alteration
Partial demolition in conjunction with ALT-1 application #S00961961-I1
S00962797-I1
03/14/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
MICHAEL KARANTINIDIS, P.E.
03/14/2025
Special inspection requirement — HVAC-R and service water heating equipment
MICHAEL KARANTINIDIS, P.E.
03/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Radomir Delic
03/14/2025
Special inspection requirement — Maintenance information
Radomir Delic
03/14/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
MICHAEL KARANTINIDIS, P.E.
03/14/2025
Special inspection requirement — Permanent certificate
Radomir Delic
03/14/2025
Special inspection requirement — Energy Code Compliance Inspections
Radomir Delic
03/14/2025
Special inspection requirement — HVAC-R and service water heating system controls
MICHAEL KARANTINIDIS, P.E.
03/10/2025
Permit issued — Mechanical Systems
S00961961-I1-GC-CX
12/13/2024
Violation issued (ECB, closed)
Construction
11/29/2024
Permit issued — Plumbing
S00961961-S2-PL
10/17/2024
Permit issued — Foundation
S01015121-I1-FO
10/16/2024
Permit issued — Support of Excavation
S01013122-I1-SE
10/16/2024
Permit issued — Foundation
S00994496-I1-FO
10/15/2024
Permit issued — General Construction
S00962797-I1-GC
10/15/2024
Permit issued — Construction Fence
S00955797-I1-FN
07/31/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
New Plumbing System filed in conjunction with Alt1 application #S00961961-I1
S00961961-S2
06/14/2024
Filed — Alteration
S00994496-P2
06/14/2024
Filed — Alteration
S01013122-P1
06/14/2024
Special inspection requirement — Subgrade Inspections
Radomir Delic
06/14/2024
Special inspection requirement — Underpinning and alternate methods of support of buildings and adjacent property
Radomir Delic
06/14/2024
Special inspection requirement — Footing and Foundation
Radomir Delic
06/14/2024
Special inspection requirement — Final
Radomir Delic
06/14/2024
Special inspection requirement — Underpinning and alternate methods of support of buildings and adjacent property
Radomir Delic
06/14/2024
Special inspection requirement — Subgrade Inspections
Radomir Delic
05/30/2024
Violation issued (ECB, closed)
Construction
04/25/2024
Permit issued — Foundation
S01015121-I1-FO
Latest 60 of 70 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMONTANA COOLING & HEATING01/20/2026
DOB NOWPlumbingPermit IssuedIPS PLUMBING CORP11/28/2025
DOB NOWStructuralPermit IssuedMONTANA COOLING & HEATING11/12/2025
DOB NOWConstruction FencePermit IssuedNODE SYSTEMS AND ASSEMBLI11/12/2025
DOB NOWMechanical SystemsPermit IssuedMONTANA COOLING & HEATING03/10/2025
DOB NOWPlumbingPermit IssuedIPS PLUMBING CORP11/29/2024
DOB NOWFoundationSigned-offNODE SYSTEMS AND ASSEMBLI10/17/2024
DOB NOWSupport of ExcavationSigned-offNODE SYSTEMS AND ASSEMBLI10/16/2024
DOB NOWFoundationSigned-offNODE SYSTEMS AND ASSEMBLI10/16/2024
DOB NOWGeneral ConstructionSigned-offNODE SYSTEMS AND ASSEMBLI10/15/2024
DOB NOWConstruction FencePermit IssuedNODE SYSTEMS AND ASSEMBLI10/15/2024
DOB NOWFoundationSigned-offNODE SYSTEMS AND ASSEMBLI04/25/2024
DOB NOWFoundationSigned-offNODE SYSTEMS AND ASSEMBLI03/01/2024
DOB NOWGeneral ConstructionSigned-offNODE SYSTEMS AND ASSEMBLI01/09/2024
DOB NOWConstruction FencePermit IssuedNODE SYSTEMS AND ASSEMBLI11/14/2023
1 project · most recent 07/31/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/31/2026Permit IssuedMONTANA COOLING & HEATINGHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MSZ-GL09NA 10,900 BTU · Fan Coil Indoor ×10
MXZ-2C20NA4 22,000 BTU · Condensing Unit ×2
1 project · most recent 07/31/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/31/2026Permit IssuedIPS PLUMBING CORPGas, Storm, Water/Sanitary
2 projects · most recent 10/24/2025
General Wiring
FiledStatusContractorScope
10/24/2025Permit IssuedTRINCITY ELECTRIC, INCGeneral Wiring
02/12/2024Permit IssuedTRINCITY ELECTRIC, INC1 meters, 1 new_meters
1 project · most recent 07/31/2026
FiledStatusContractorScope
07/31/2026Permit IssuedMONTANA COOLING & HEATING1 scope_items
1 project · most recent 11/07/2023
Fence
FiledStatusContractorScope
11/07/2023Permit IssuedNODE SYSTEMS AND ASSEMBLIFence
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/24/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/21/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/12/2025No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
09/17/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
09/17/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/10/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 70
DateRequirementInspectorRole
06/09/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationMICHAEL KARANTINIDIS, P.E.special
06/09/2026Fire-Resistant Penetrations and JointsRadomir Delicspecial
06/09/2026HVAC-R and service water piping design and insulationMICHAEL KARANTINIDIS, P.E.energy_progress
06/09/2026Maintenance informationMICHAEL KARANTINIDIS, P.E.energy_progress
06/09/2026Permanent certificateMICHAEL KARANTINIDIS, P.E.energy_progress
06/09/2026HVAC-R and service water heating system controlsMICHAEL KARANTINIDIS, P.E.energy_progress
06/09/2026HVAC-R and service water heating equipmentMICHAEL KARANTINIDIS, P.E.energy_progress
06/09/2026Energy Code Compliance InspectionsRadomir Delicprogress
10/15/2025HVAC-R and service water piping design and insulationMICHAEL KARANTINIDIS, P.E.energy_progress
10/15/2025HVAC-R and service water heating system controlsMICHAEL KARANTINIDIS, P.E.energy_progress
10/15/2025Fire-Resistant Penetrations and JointsRadomir Delicspecial
10/15/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationMICHAEL KARANTINIDIS, P.E.special
10/15/2025Energy Code Compliance InspectionsRadomir Delicprogress
10/15/2025Permanent certificateRadomir Delicenergy_progress
10/15/2025HVAC-R and service water heating equipmentMICHAEL KARANTINIDIS, P.E.energy_progress
10/15/2025Maintenance informationRadomir Delicenergy_progress
03/14/2025Energy Code Compliance InspectionsRadomir Delicprogress
03/14/2025Fire-Resistant Penetrations and JointsRadomir Delicspecial
03/14/2025Permanent certificateRadomir Delicenergy_progress
03/14/2025HVAC-R and service water heating system controlsMICHAEL KARANTINIDIS, P.E.energy_progress
03/14/2025Maintenance informationRadomir Delicenergy_progress
03/14/2025HVAC-R and service water heating equipmentMICHAEL KARANTINIDIS, P.E.energy_progress
03/14/2025HVAC-R and service water piping design and insulationMICHAEL KARANTINIDIS, P.E.energy_progress
03/14/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationMICHAEL KARANTINIDIS, P.E.special
06/14/2024Subgrade InspectionsRadomir Delicspecial
Latest 25 of 70.
▾Documents — 108 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch13
08/22/2026S00955797-I1Request digital key ↗
08/21/2026S00962797-I1Request digital key ↗
08/21/2026S00994496-I1Request digital key ↗
Showing 3 of 13 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
09/13/2024540263702Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
09/19/2024540263702Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/18/2026S00961961-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/18/2026S00961961-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/18/2026S00961961-I1Open ↗
▸Seals & Professional Certifications70
▸DOB NOWProgress Inspector Seal & Signature35
09/01/2026S00961961-P2Open ↗
09/01/2026S00961961-P2Open ↗
09/01/2026S00961961-P2Open ↗
Showing 3 of 35 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature20
09/01/2026S00961961-P2Open ↗
09/01/2026S00961961-P2Open ↗
09/01/2026S00961961-P3Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/21/2026S00994496-I1Open ↗
08/21/2026S00994496-P1Open ↗
08/21/2026S00994496-P2Open ↗
Showing 3 of 13 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
09/13/2024540263702Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/13/2024540263702Open ↗
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/18/2026S00961961-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
08/18/2026S00961961-S2Open ↗
08/18/2026S00961961-I1Open ↗
08/13/2026S00962797-I1Open ↗
▸Inspections & Test Reports5
▸DOB NOWGeotechnical Report (BC 1803.6)3
08/13/2026S00994496-I1Open ↗
08/13/2026S01015121-I1Open ↗
08/13/2026S01013122-I1Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
09/19/2024540263702Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/13/2024540263702Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
09/19/2024540263702Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
09/13/2024540263702Open ↗
▸BISADDITIONAL INFORMATION1
09/19/2024540263702Open ↗
▸Other Documents8
▸BISBPP - SUPPORTING DOCUMENTATION2
09/19/2024540263702Open ↗
09/19/2024540263702Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
09/19/2024540263702Open ↗
▸DOB NOWPlot Diagram1
08/13/2026S01015121-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/18/2026S00961961-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/18/2026S00961961-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/18/2026S00961961-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026S01013122-I1Open ↗