← Back
Office only, 2-6 stories
138 EAST 80 STREET
MANHATTAN · Upper East Side-Carnegie Hill · BIN 1047488
💬 Discuss this project
1899Year Built
5Stories
O2Building Class
C1-8XZoning
12,437 sfGross Floor Area
1Units
0 Open Violations
Office only, 2-6 stories · Owner of record: 138-140 EAST 80 · 3,747 sf lot · 3.32 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionLandscapeCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction34p · 4 filings · 20 docs
Floor 5Under Construction43p · 7 filings · 20 docs
Floor 4Under Construction39p · 8 filings · 20 docs
Floor 3Under Construction45p · 7 filings · 20 docs
Floor 2Under Construction36p · 6 filings · 20 docs
Floor 1Under Construction34p · 5 filings · 20 docs
CellarUnder Construction29p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
138-140 EAST 808008/20/2026
CITY SCAFFLOD CORP103/22/2026
RETINA ASSOCIATES OF NEW YORK203/21/2026
RETINA ASSOCIATES603/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING4403/21/2026
PAUL FUSCO CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FULL SCALE CONTRACTING INGeneral Contractor1707/08/2026
CHRISTOPHER TEETERElectrical403/21/2026
NY PLUMBING & HEATING CORPlumbing307/08/2026
P & D MECHANICAL CORPFire Protection207/08/2026
MILL BROOK FIRE PROTECTIONFire Protection107/08/2026
ERIC & NG ELEC'L, INC.Electrical103/22/2026
INNOVATIVE HEATING SOLUTIPlumbing107/08/2026
L & N PLUMBING, INCPlumbing107/08/2026
ERIC AUElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CNY ENGINEERING P.C3304105/18/2026
R.J. MCGEE ENGINEERING, P9435104/30/2025
ASSURE PROFESSIONAL ENGIN69621603/20/2025
THE EIPEL ENGINEERING GRO2714106/20/2022
Building Lifecycle
All (102)Filed (21)Permit Issued (20)Signed Off (6)Violation (4)Inspection (15)Objection (6)Special Inspection (30)
08/19/2026
Permit issued — Boiler Equipment
M00606644-S1-BE
05/18/2026
Filed — Alteration
PROPOSE TO INSTALL NEW FUEL STORAGE TANK CONNECTED WITH A GENERATOR FILED IN CONJUNCTION WITH DOB NOW GC #M00636395 FILED FOR INTERIOR TENANT FIT-OUT SPACE FOR AMBULATORY SURGERY OFFICE. NO CHANGE IN USE, EGRESS, OCCUPANCY.
M00606644-S1
12/04/2025
Permit issued — Mechanical Systems
M00636537-I1-MS
09/29/2025
Permit issued — Mechanical Systems
M00636537-I1-MS
09/26/2025
Permit issued — Mechanical Systems
M01212413-I1-MS
09/16/2025
Permit issued — Mechanical Systems
M00636537-I1-MS
06/14/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/30/2025
Filed — Alteration
M01212413-I1
03/20/2025
Filed — Alteration
PROPOSE MECHANICAL WORK TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK FILED IN CONJUNCTION WITH GC JOB # M00636395 FOR INTERIOR TENANT FIT-OUT SPACE. NO CHANGE IN EGRESS, USE, OCCUPANCY.
M00636537-P3
03/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GUNJAN KHANDWALA
03/18/2025
Special inspection requirement — HVAC-R and service water heating system controls
GUNJAN KHANDWALA
03/18/2025
Special inspection requirement — HVAC-R and service water heating equipment
GUNJAN KHANDWALA
03/18/2025
Special inspection requirement — Post-installed Anchors
GUNJAN KHANDWALA
03/18/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
GUNJAN KHANDWALA
03/18/2025
Special inspection requirement — Mechanical Systems
GUNJAN KHANDWALA
03/18/2025
Special inspection requirement — Final
JAMES TERJESEN
03/18/2025
Special inspection requirement — Shutoff dampers
GUNJAN KHANDWALA
03/18/2025
Special inspection requirement — Maintenance information
GUNJAN KHANDWALA
03/06/2025
Signed off — Alteration
PROPOSE MEDICAL GAS WORK FILED IN CONJUNCTION WITH DOB NOW GC #M00636395 FOR INTERIOR TENANT FIT-OUT SPACE FOR AMBULATORY SURGERY CENTER. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
M00695711-I1
02/10/2025
Filed — Alteration
PROPOSE MECHANICAL WORK TO INCLUDE HVAC REPLACEMENT AND REPLACEMENT OF ASSOCIATED DUCTWORK FILED IN CONJUNCTION WITH GC JOB # M00636395 FOR INTERIOR TENANT FIT-OUT SPACE. NO CHANGE IN EGRESS, USE, OCCUPANCY.
M00636537-P2
02/05/2025
Signed off — Alteration
MECHANICAL MODIFICATIONS TO INCLUDE INSTALLATION OF NEW BOILER. NO CHANGE OF USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01017946-I1
02/05/2025
Signed off — Alteration
PROPOSE PLUMBING WORK FILED IN CONJUNCTION WITH DOB NOW GC #M00636395 FOR INTERIOR TENANT FIT-OUT SPACE FOR AMBULATORY SURGERY CENTER. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
M00637541-I1
02/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GUNJAN KHANDWALA
02/03/2025
Special inspection requirement — Mechanical Systems
GUNJAN KHANDWALA
02/03/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
GUNJAN KHANDWALA
02/03/2025
Special inspection requirement — Maintenance information
GUNJAN KHANDWALA
02/03/2025
Special inspection requirement — Post-installed Anchors
GUNJAN KHANDWALA
02/03/2025
Special inspection requirement — HVAC-R and service water heating equipment
GUNJAN KHANDWALA
02/03/2025
Special inspection requirement — Shutoff dampers
GUNJAN KHANDWALA
02/03/2025
Special inspection requirement — Final
JAMES TERJESEN
02/03/2025
Special inspection requirement — HVAC-R and service water heating system controls
GUNJAN KHANDWALA
01/17/2025
Signed off — Alteration
PROPOSE SPRINKLER WORK FILED IN CONJUNCTION WITH DOB NOW GC #M00636395 FOR INTERIOR TENANT FIT-OUT SPACE FOR AMBULATORY SURGERY CENTER. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
M00637549-I1
01/09/2025
Inspection — Certified Medical Gas - MG - PL - Finish
Certified
View inspection ↗
01/09/2025
Inspection — Certified Medical Gas - MG - PL - Roughing
Certified
View inspection ↗
01/09/2025
Inspection — Certified Medical Gas - MG - PL - Test
Certified
View inspection ↗
01/06/2025
Permit issued — Plumbing
M00695711-I1-PL
12/19/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/07/2024
Special inspection requirement — Post-installed Anchors
GUNJAN KHANDWALA
11/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GUNJAN KHANDWALA
11/07/2024
Special inspection requirement — Sprinkler Systems
GUNJAN KHANDWALA
10/31/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
GUNJAN KHANDWALA
10/31/2024
Special inspection requirement — HVAC-R and service water heating equipment
GUNJAN KHANDWALA
10/31/2024
Special inspection requirement — HVAC-R and service water heating system controls
GUNJAN KHANDWALA
10/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GUNJAN KHANDWALA
10/31/2024
Special inspection requirement — Energy Code Compliance Inspections
GUNJAN KHANDWALA
10/29/2024
Filed — Alteration
PROPOSE PLUMBING WORK FILED IN CONJUNCTION WITH DOB NOW GC #M00636395 FOR INTERIOR TENANT FIT-OUT SPACE FOR AMBULATORY SURGERY CENTER. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
M00637541-P3
10/17/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/17/2024
Special inspection requirement — Energy Code Compliance Inspections
GUNJAN KHANDWALA
10/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GUNJAN KHANDWALA
10/17/2024
Special inspection requirement — HVAC-R and service water heating equipment
GUNJAN KHANDWALA
10/17/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
GUNJAN KHANDWALA
09/26/2024
Filed — Alteration
PROPOSE SPRINKLER WORK FILED IN CONJUNCTION WITH DOB NOW GC #M00636395 FOR INTERIOR TENANT FIT-OUT SPACE FOR AMBULATORY SURGERY CENTER. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
M00637549-P3
09/20/2024
Filed — Alteration
PROPOSE PLUMBING WORK FILED IN CONJUNCTION WITH DOB NOW GC #M00636395 FOR INTERIOR TENANT FIT-OUT SPACE FOR AMBULATORY SURGERY CENTER. NO CHANGE IN EGRESS, USE, OR OCCUPANCY
M00637541-P2
09/13/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/05/2024
Permit issued — Plumbing
M00637541-I1-PL
08/05/2024
Permit issued — Boiler Equipment
M01017946-I1-BE
07/31/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
07/28/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/28/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/28/2024
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
Latest 60 of 102 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentPermit IssuedFRANK MOORE08/19/2026
DOB NOWMechanical SystemsPermit IssuedFULL SCALE CONTRACTING IN12/04/2025
DOB NOWMechanical SystemsPermit IssuedFULL SCALE CONTRACTING IN09/29/2025
DOB NOWMechanical SystemsPermit IssuedFULL SCALE CONTRACTING IN09/26/2025
DOB NOWMechanical SystemsPermit IssuedFULL SCALE CONTRACTING IN09/16/2025
DOB NOWPlumbingSigned-offL & N PLUMBING, INC01/06/2025
DOB NOWPlumbingSigned-offNY PLUMBING & HEATING COR09/05/2024
DOB NOWBoiler EquipmentSigned-offMITIE PLUMBING & HTG CORP08/05/2024
DOB NOWSprinklersSigned-offLEGUCI PIPING&HEATING LLC02/20/2024
DOB NOWMechanical SystemsPermit IssuedFULL SCALE CONTRACTING IN10/02/2023
DOB NOWGeneral ConstructionSigned-offFULL SCALE CONTRACTING IN10/02/2023
DOB NOWSprinklersSigned-offP & D MECHANICAL CORP07/13/2023
DOB NOWPlumbingSigned-offNY PLUMBING & HEATING COR07/01/2023
DOB NOWMechanical SystemsPermit IssuedFULL SCALE CONTRACTING IN01/05/2023
DOB NOWStructuralPermit IssuedFULL SCALE CONTRACTING IN10/20/2022
DOB NOWGeneral ConstructionSigned-offFULL SCALE CONTRACTING IN10/19/2022
DOB NOWStructuralPermit IssuedFULL SCALE CONTRACTING IN06/27/2022
DOB NOWSprinklersSigned-offP & D MECHANICAL CORP06/03/2022
DOB NOWGeneral ConstructionSigned-offFULL SCALE CONTRACTING IN05/13/2022
DOB NOWPlumbingSigned-offNY PLUMBING & HEATING COR05/12/2022
BIS—ISSUEDFULL SCALE CONTRACTING IN01/07/2026
BIS—ISSUEDFULL SCALE CONTRACTING IN11/18/2021
BISCCRE-ISSUEDLAPIETRA CONTRACTING CORP08/23/2006
BISPLISSUEDNYC WATER MAIN WORKS05/17/2006
BISPLISSUEDPILATO BROS PLBG & HTG CO04/13/2006
BIS—ISSUEDEASTCO CONTRACTORS CO.INC06/17/2004
BISPLISSUEDPILATO BROS PLBG & HTG CO09/25/2003
BISOTISSUEDEASTCO CONTR CO INC.06/24/2003
BIS—ISSUEDEASTCO CONTRACTORS CO.INC05/28/2003
BIS—ISSUEDMZM CORP05/14/2002
BISEQISSUEDCITY SCAFF. COPR02/14/2002
BIS—ISSUEDRANERI BROTHERS CONST.05/15/2001
BISPLISSUEDBRONZE PLUMBING & HEATING CO.01/31/2000
BIS—ISSUEDRANERI BROTHERS CONST.01/31/2000
BISPLISSUEDBRONZE PLMB & HTNG CO05/11/1999
BISMHISSUEDJAMES AND THOMAS RANIERI04/29/1999
1 project · most recent 03/20/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/20/2025Permit IssuedFULL SCALE CONTRACTING INAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Lg ARUN024GSS4 24,000 BTU · Vrf Outdoor ×10
ARUN060GSS4 60,000 BTU · Vrf Outdoor ×10
ARUN038GSS4 38,000 BTU · Vrf Outdoor ×5
Aaon RN-011-8-0-EB09 128,290 BTU · Rooftop Unit ×5
Heating
Lg ARUN024GSS4 27,000 BTU · Vrf Outdoor ×10
ARUN060GSS4 64,000 BTU · Vrf Outdoor ×10
ARUN038GSS4 42,000 BTU · Vrf Outdoor ×5
Aaon RN-011-8-0-EB09 195,000 BTU · Rooftop Unit ×5
Ventilation
Greenheck AS-10-420-A 270 CFM · Exhaust Fan ×10
SP-A200 75 CFM · Exhaust Fan ×10
G-099-VG 585 CFM · Exhaust Fan ×5
1 project · most recent 01/07/2026
General Wiring
FiledStatusContractorScope
01/07/2026CompleteERIC & NG ELEC'L, INC.General Wiring
▾Field Inspections (DOB CAP) — 15
DateTypeResultReport
06/14/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/09/2025Certified Medical Gas - MG - PL - FinishCertifiedView ↗
01/09/2025Certified Medical Gas - MG - PL - RoughingCertifiedView ↗
01/09/2025Certified Medical Gas - MG - PL - TestCertifiedView ↗
12/19/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/17/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/13/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/31/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/28/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/28/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/28/2024Certified Sprinkler - SP - RoughingCertifiedView ↗
04/04/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/04/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/30/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/30/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 96
DateRequirementInspectorRole
03/18/2025HVAC-R and service water piping design and insulationGUNJAN KHANDWALAenergy_progress
03/18/2025Fire-Resistant Penetrations and JointsGUNJAN KHANDWALAspecial
03/18/2025Mechanical SystemsGUNJAN KHANDWALAspecial
03/18/2025Post-installed AnchorsGUNJAN KHANDWALAspecial
03/18/2025FinalJAMES TERJESENprogress
03/18/2025HVAC-R and service water heating system controlsGUNJAN KHANDWALAenergy_progress
03/18/2025HVAC-R and service water heating equipmentGUNJAN KHANDWALAenergy_progress
03/18/2025Maintenance informationGUNJAN KHANDWALAenergy_progress
03/18/2025Shutoff dampersGUNJAN KHANDWALAenergy_progress
02/03/2025HVAC-R and service water piping design and insulationGUNJAN KHANDWALAenergy_progress
02/03/2025Fire-Resistant Penetrations and JointsGUNJAN KHANDWALAspecial
02/03/2025Mechanical SystemsGUNJAN KHANDWALAspecial
02/03/2025Post-installed AnchorsGUNJAN KHANDWALAspecial
02/03/2025FinalJAMES TERJESENprogress
02/03/2025Maintenance informationGUNJAN KHANDWALAenergy_progress
02/03/2025HVAC-R and service water heating equipmentGUNJAN KHANDWALAenergy_progress
02/03/2025Shutoff dampersGUNJAN KHANDWALAenergy_progress
02/03/2025HVAC-R and service water heating system controlsGUNJAN KHANDWALAenergy_progress
11/07/2024Post-installed AnchorsGUNJAN KHANDWALAspecial
11/07/2024Fire-Resistant Penetrations and JointsGUNJAN KHANDWALAspecial
11/07/2024Sprinkler SystemsGUNJAN KHANDWALAspecial
10/31/2024Fire-Resistant Penetrations and JointsGUNJAN KHANDWALAspecial
10/31/2024Energy Code Compliance InspectionsGUNJAN KHANDWALAprogress
10/31/2024HVAC-R and service water heating equipmentGUNJAN KHANDWALAenergy_progress
10/31/2024HVAC-R and service water piping design and insulationGUNJAN KHANDWALAenergy_progress
Latest 25 of 96.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Surgery Center of New YorkMedical / HealthcareCellar, Floors 1–5, Roof
Project M01212413 Alteration · Permit Entire · 04/30/2025
Project M00636537 Alteration · Permit Entire · 01/14/2022
Retinal Ambulatory Surgery CenterMedical / HealthcareFloors 4, 5
Project M00606644 Alteration · Permit Entire · 02/13/2024
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 200 on file (BIS + DOB NOW)
▸Plans & Drawings23
▸DOB NOWPlans/Sketch23
09/06/2026M00738200-I1Request digital key ↗
09/06/2026M01004887-I1Request digital key ↗
09/02/2026M00695711-I1Request digital key ↗
Showing 3 of 23 on file for this type
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION6
12/16/2024121189533Open ↗
10/15/2021121189533Open ↗
03/18/2020121189533Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION2
01/07/2026121189533Open ↗
11/18/2021121189533Open ↗
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
11/18/2021121189533Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
01/28/2025121189533Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
08/13/2019121189533Open ↗
▸BISZONING DIAGRAM1
03/17/2020121189533Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
03/17/2020121189533Open ↗
▸Seals & Professional Certifications103
▸DOB NOWProgress Inspector Seal & Signature48
09/29/2026M00636537-P1Open ↗
09/29/2026M00636537-P1Open ↗
09/29/2026M00636537-P1Open ↗
Showing 3 of 48 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature33
09/29/2026M00636537-P1Open ↗
09/29/2026M00636537-P1Open ↗
09/29/2026M00636537-P1Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature22
09/06/2026M00738200-I1Open ↗
09/02/2026M00695711-I1Open ↗
09/02/2026M00742835-I1Open ↗
Showing 3 of 22 on file for this type
▸Safety & Tenant Protection2
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
11/18/2021121189533Open ↗
▸BISSTREET TREE CHECKLIST1
03/23/2020121189533Open ↗
▸Environmental & Asbestos24
▸DOB NOWDEP ACP-5: Asbestos Assessment Report23
09/06/2026M00738200-I1Open ↗
09/02/2026M00695711-I1Open ↗
09/02/2026M00742835-I1Open ↗
Showing 3 of 23 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/01/2019121189533Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
02/03/2025121189533Open ↗
11/18/2021121189533Open ↗
02/01/2019121189533Open ↗
▸DOB NOWEN2: As Built Energy Analysis3
08/13/2026M00637541-I1Open ↗
08/13/2026M00636395-I1Open ↗
08/13/2026M00636537-I1Open ↗
▸BISINTERIOR LIGHTING POWER1
02/03/2025121189533Open ↗
▸BISLIGHTING CONTROLS1
02/03/2025121189533Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
02/03/2025121189533Open ↗
▸Inspections & Test Reports12
▸BISTECHNICAL REPORT: RESPONSIBILITY6
02/13/2025121189533Open ↗
02/03/2025121189533Open ↗
11/18/2021121189533Open ↗
Showing 3 of 6 on file for this type
▸BISSTRUCTURAL STEEL - DETAILS1
02/13/2025121189533Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
02/03/2025121189533Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
02/03/2025121189533Open ↗
▸BISSTRUCTURAL STEEL - HIGH STRENGTH BOLTING1
02/13/2025121189533Open ↗
▸BISSTRUCTURAL STEEL - WELDING1
02/13/2025121189533Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
02/13/2025121189533Open ↗
▸Approvals, Objections & Sign-offs4
▸BISSCHEDULE A - OCCUPANCY / USE2
02/27/2020121189533Open ↗
10/18/2019121189533Open ↗
▸BISTRANSIT AUTHORITY/MTA/PANYNJ APPROVAL1
03/17/2020121189533Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/17/2020121189533Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
03/24/2020121189533Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION5
11/18/2021121189533Open ↗
11/15/2021121189533Open ↗
03/23/2020121189533Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM1
01/07/2026121189533Open ↗
▸Other Documents3
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
03/17/2020121189533Open ↗
08/13/2019121189533Open ↗
▸BISPLOT DIAGRAM1
08/13/2019121189533Open ↗