← Back
Single or multiple dwelling with stores or offices
140 5 AVENUE
BROOKLYN · BIN 3019166
💬 Discuss this project
1930Year Built
4Stories
S9Building Class
R6AZoning
7,140 sfGross Floor Area
8Units
Rent Stabilized54 Open Violations 53 unresolved · 1 paperwork only ▸FDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: URBAN STORIES I LLC · 2,678 sf lot · 2.67 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction3p · 1 filing · 20 docs
Floor 1Under Construction14p · 1 filing · 20 docs
CellarUnder Construction20p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BROWNSTONE MANAGEMENT1108/29/2026
URBAN STORIES I LLC103/22/2026
THE OWNER OF203/22/2026
HOUSING PRESERVATION &806103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEON SKVIRSKY PE108/07/2026
MOTOKO TISZA304/19/2026
ROSENTHAL ENGINEERING PLLC304/05/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RICHARD LEWIS ARCHITECT303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ERGO DEVELOPMENT & MGMN'TGeneral Contractor307/08/2026
GREGG NY PLUMBING, INCPlumbing107/08/2026
PAUL SIGNSScaffold108/12/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
METROSPEC SIA6420404/05/2026
Building Lifecycle
All (111)Filed (7)Permit Issued (5)Violation (60)Inspection (9)Special Inspection (30)
08/11/2026
Permit issued — Sign
B01433353-I1-SG
08/07/2026
Filed — Alteration
INSTALL EXTERIOR NON-ILLUMINATED BLADE SIGN (THORSDAY)
B01433353-I1
07/20/2026
Special inspection requirement — Final
LEON SKVIRSKY
07/07/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/16/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/19/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/15/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/23/2026
Special inspection requirement — Mechanical Systems
JOSEPH YOUNG
04/23/2026
Special inspection requirement — Final
JOSEPH YOUNG
04/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
JOSEPH YOUNG
04/23/2026
Special inspection requirement — Tenant Protection Plan Compliance
JOSEPH YOUNG
04/23/2026
Special inspection requirement — Shutoff dampers
JOSEPH YOUNG
04/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
JOSEPH YOUNG
04/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
JOSEPH YOUNG
04/23/2026
Special inspection requirement — Maintenance information
JOSEPH YOUNG
04/20/2026
Special inspection requirement — Tenant Protection Plan Compliance
04/20/2026
Special inspection requirement — Final
JOSEPH YOUNG
04/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
JOSEPH YOUNG
04/19/2026
Filed — Alteration
Installation of new mechanical HVAC and ventilation as per plan. Installation of new hood/exhaust system as per plan.
B01207808-P2
04/15/2026
Permit issued — General Construction
B01207808-I1-GC
04/14/2026
Special inspection requirement — Fire-Resistance Rated Construction
JOSEPH YOUNG
04/14/2026
Special inspection requirement — Final
JOSEPH YOUNG
04/14/2026
Special inspection requirement — Tenant Protection Plan Compliance
04/05/2026
Filed — Alteration
Installation of new mechanical HVAC and ventilation as per plan. Installation of new hood/exhaust system as per plan.
B01207808-P1
04/03/2026
Filed — Alteration
Installation of new mechanical HVAC and ventilation as per plan. Installation of new hood/exhaust system as per plan.
B01207808-S3
04/01/2026
Special inspection requirement — Shutoff dampers
JOSEPH YOUNG
04/01/2026
Special inspection requirement — Tenant Protection Plan Compliance
JOSEPH YOUNG
04/01/2026
Special inspection requirement — Mechanical Systems
JOSEPH YOUNG
04/01/2026
Special inspection requirement — Final
JOSEPH YOUNG
04/01/2026
Special inspection requirement — HVAC-R and service water heating equipment
JOSEPH YOUNG
04/01/2026
Special inspection requirement — Maintenance information
JOSEPH YOUNG
04/01/2026
Special inspection requirement — HVAC-R and service water heating system controls
JOSEPH YOUNG
04/01/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
JOSEPH YOUNG
03/19/2026
Special inspection requirement — Insulation placement and R values
JOSEPH YOUNG
03/19/2026
Special inspection requirement — Fenestration areas
JOSEPH YOUNG
03/19/2026
Special inspection requirement — Fenestration air leakage
JOSEPH YOUNG
03/19/2026
Special inspection requirement — Final
JOSEPH YOUNG
03/19/2026
Special inspection requirement — Tenant Protection Plan Compliance
JOSEPH YOUNG
03/19/2026
Special inspection requirement — Energy Code Compliance Inspections
JOSEPH YOUNG
03/19/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
JOSEPH YOUNG
02/11/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/03/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/30/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/27/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/20/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/16/2026
Permit issued — Plumbing
B01207808-S1-PL
12/13/2025
Violation issued (HPD, open)
C
12/09/2025
Violation issued (HPD, closed)
C
11/27/2025
Violation issued (HPD, open)
B
11/27/2025
Violation issued (HPD, open)
B
10/15/2025
Permit issued — Mechanical Systems
B01207808-S2-MS
09/30/2025
Permit issued — General Construction
B01207808-I1-GC
05/28/2025
Filed — Alteration
Installation of new mechanical HVAC and ventilation as per plan. Installation of new hood/exhaust system as per plan.
B01207808-S2
05/22/2025
Filed — Alteration
Installation of new mechanical HVAC and ventilation as per plan. Installation of new hood/exhaust system as per plan.
B01207808-S1
04/30/2025
Filed — Alteration
Installation of new mechanical HVAC and ventilation as per plan. Installation of new hood/exhaust system as per plan.
B01207808-I1
03/31/2025
Violation issued (FDNY_ORDER, closed)
03/31/2025
Violation issued (FDNY_ORDER, closed)
03/08/2024
Violation issued (HPD, closed)
B
03/08/2024
Violation issued (HPD, open)
C
03/08/2024
Violation issued (HPD, open)
C
Latest 60 of 111 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignPermit IssuedPAUL SIGNS, INC08/11/2026
DOB NOWGeneral ConstructionPermit IssuedERGO DEVELOPMENT & MGMN'T04/15/2026
DOB NOWPlumbingPermit IssuedGREGG NY PLUMBING, INC01/16/2026
DOB NOWMechanical SystemsPermit IssuedERGO DEVELOPMENT MGMNT10/15/2025
DOB NOWGeneral ConstructionPermit IssuedERGO DEVELOPMENT MGMNT09/30/2025
BISFPISSUEDNEW YORK BUSINESS FIRE SYSTEM I.04/21/2008
BISOTISSUEDGRAND WATERPROOFING CO05/07/1998
BISEQISSUEDGATEWAY DEMO/CIVIL CORP03/11/1998
1 project · most recent 04/19/2026
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/19/2026Permit IssuedERGO DEVELOPMENT & MGMN'TAir Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric MITSUBISHI MUZ-FS09NA 9,000 BTU · Condensing Unit ×2
MITSUBISHI PUZ-A24NHA7 24,000 BTU · Condensing Unit ×2
MITSUBISHI PUZ-HA36NKA7 36,000 BTU · Condensing Unit ×2
Ventilation
Panasonic FV-11-15VK1 150 CFM · Exhaust Fan ×2
1 project · most recent 04/19/2026
Water/Sanitary
FiledStatusContractorScope
04/19/2026Permit IssuedGREGG NY PLUMBING, INCWater/Sanitary
2 projects · most recent 07/06/2026
General Wiring
FiledStatusContractorScope
07/06/2026Permit IssuedELECTRICAL SOLUTIONS LLCGeneral Wiring
08/15/2023CompleteAMC ELEC'L SERVICES, INC.General Wiring
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
07/07/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/16/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/19/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/15/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/11/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/03/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/30/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/27/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/20/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
07/20/2026FinalLEON SKVIRSKYprogress
04/23/2026Mechanical SystemsJOSEPH YOUNGspecial
04/23/2026FinalJOSEPH YOUNGprogress
04/23/2026HVAC-R and service water piping design and insulationJOSEPH YOUNGenergy_progress
04/23/2026Tenant Protection Plan ComplianceJOSEPH YOUNGspecial
04/23/2026Shutoff dampersJOSEPH YOUNGenergy_progress
04/23/2026HVAC-R and service water heating system controlsJOSEPH YOUNGenergy_progress
04/23/2026HVAC-R and service water heating equipmentJOSEPH YOUNGenergy_progress
04/23/2026Maintenance informationJOSEPH YOUNGenergy_progress
04/20/2026Tenant Protection Plan Compliance—special
04/20/2026FinalJOSEPH YOUNGprogress
04/20/2026Fire-Resistance Rated ConstructionJOSEPH YOUNGprogress
04/14/2026Fire-Resistance Rated ConstructionJOSEPH YOUNGprogress
04/14/2026FinalJOSEPH YOUNGprogress
04/14/2026Tenant Protection Plan Compliance—special
04/01/2026Shutoff dampersJOSEPH YOUNGenergy_progress
04/01/2026Tenant Protection Plan ComplianceJOSEPH YOUNGspecial
04/01/2026Mechanical SystemsJOSEPH YOUNGspecial
04/01/2026FinalJOSEPH YOUNGprogress
04/01/2026HVAC-R and service water heating equipmentJOSEPH YOUNGenergy_progress
04/01/2026Maintenance informationJOSEPH YOUNGenergy_progress
04/01/2026HVAC-R and service water heating system controlsJOSEPH YOUNGenergy_progress
04/01/2026HVAC-R and service water piping design and insulationJOSEPH YOUNGenergy_progress
03/19/2026Insulation placement and R valuesJOSEPH YOUNGenergy_progress
03/19/2026Fenestration areasJOSEPH YOUNGenergy_progress
Latest 25 of 30.
▾Documents — 40 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/17/2026B01207808-S3Request digital key ↗
08/17/2026B01207808-S1Request digital key ↗
08/17/2026B01207808-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
04/09/2008310126850Open ↗
▸BISWORK PERMIT APPLICATION1
04/21/2008310126850Open ↗
▸Seals & Professional Certifications20
▸DOB NOWProgress Inspector Seal & Signature9
09/01/2026B01207808-I1Open ↗
08/31/2026B01207808-S3Open ↗
08/31/2026B01207808-S3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/17/2026B01207808-S2Open ↗
08/17/2026B01207808-S1Open ↗
08/17/2026B01207808-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/31/2026B01207808-S3Open ↗
08/27/2026B01207808-S2Open ↗
08/26/2026B01207808-P1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
04/09/2008310126850Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/17/2026B01207808-S2Open ↗
08/17/2026B01207808-I1Open ↗
08/17/2026B01207808-S1Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
04/09/2008310126850Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
04/10/2008310126850Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
04/21/2008310126850Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
04/09/2008310126850Open ↗
▸Other Documents2
▸DOB NOWProof of Historic Building2
08/13/2026B01207808-P2Open ↗
08/13/2026B01207808-I1Open ↗