← Back
Parochial school, yeshiva
Waterside Children's Studio School
140 BEACH 112 STREET · BIN 4303856
💬 Discuss this project
1959Year Built
3Stories
W2Building Class
R4Zoning
93,023 sfGross Floor Area
1Units
LL97 Covered29 Open Violations 23 unresolved · 6 paperwork only ▸FDNY Report ↗
Parochial school, yeshiva · 137,898 sf lot · 0.67 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction16p · 1 filing · 20 docs
Bulkhead3p · 1 filing · 3 docs
Floor 3Under Construction32p · 1 filing · 20 docs
Floor 2Under Construction31p · 1 filing · 20 docs
Floor 1Under Construction39p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ROCKLYN ASSET6107/08/2026
DEPARTMENT OF EDUCATION403/22/2026
STELLA MARIS HIGH SCHOOL403/22/2026
STELLA MARIA COMM HIGH SCHOOL203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DVL CONSULTING ENGINEERS, INC908/25/2025
THORNTON TOMASETTI204/30/2024
ENSIGN ENGINEERING, P.C.304/17/2024
SALAM & GIACALONE ARCHITECTS PC208/09/2023
ALBERTO ROMAN106/14/2020
BRAD E. COHEN, PE204/21/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PRECISION 3SIXTY NYC, INC2603/21/2026
ENSIGN ENGINEERING P C603/21/2026
CONAPAC SERVICES DBA103/21/2026
CONAPAC SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NATIONAL ENVIROMENTAL SAFETYGeneral Contractor1307/08/2026
ACS SYSTEM ASSOCIATES INC.General Contractor707/08/2026
MAR-SAL PLBG & HTG, INCPlumbing407/08/2026
ABC MADISON BUILDERS INCGeneral Contractor203/21/2026
SAVERIO GOVERNALEElectrical203/21/2026
LUCIANO, ANTHONYElectrical203/21/2026
POLONIA DEVELOPMENT & PREGeneral Contractor203/21/2026
ANTHONY LUCIANOElectrical203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
UNIVERSAL TESTING AND INS4001308/25/2025
KEYOWNER ENGINEERING, P.C4817304/17/2024
Building Lifecycle
All (144)Filed (18)Permit Issued (21)Signed Off (2)Violation (60)Inspection (5)Objection (8)Special Inspection (30)
04/30/2026
Permit issued — Mechanical Systems
Q00716806-S2-MS
04/14/2026
Signed off — Alteration
Q00354051-I1
03/31/2026
Permit issued — General Construction
Q00716806-I1-GC
03/19/2026
Violation issued (ECB, open)
Construction
03/19/2026
Violation issued (ECB, open)
Construction
03/19/2026
Violation issued (ECB, open)
Construction
03/05/2026
Violation issued (FDNY_ORDER, closed)
03/05/2026
Violation issued (FDNY_ORDER, closed)
03/05/2026
Violation issued (FDNY_ORDER, closed)
09/26/2025
Permit issued — Plumbing
Q00716806-S3-PL
08/26/2025
Special inspection requirement — Maintenance information
NELSON LOPEZ
08/26/2025
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
08/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
NELSON LOPEZ
08/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
NELSON LOPEZ
08/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
NELSON LOPEZ
08/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
08/26/2025
Special inspection requirement — Maintenance information
NELSON LOPEZ
08/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
NELSON LOPEZ
08/26/2025
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
08/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
08/25/2025
Filed — Alteration
Remove existing fixtures. Replace various flushometers and faucets. Remove existing kitchen and science instruction room along with associated piping. Install new plumbing fixtures and related piping as per plans.
Q00716806-P8
05/23/2025
Permit issued — Structural
Q00716806-S1-ST
04/30/2025
Permit issued — Mechanical Systems
Q00716806-S2-MS
04/14/2025
Violation issued (ECB, closed)
Construction
04/14/2025
Violation issued (ECB, open)
Construction
03/11/2025
Special inspection requirement — Ventilation and air distribution system
NELSON LOPEZ
03/11/2025
Special inspection requirement — HVAC-R and service water heating system controls
NELSON LOPEZ
03/11/2025
Special inspection requirement — Mechanical Systems
NELSON LOPEZ
03/11/2025
Special inspection requirement — Maintenance information
NELSON LOPEZ
03/11/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
NELSON LOPEZ
03/11/2025
Special inspection requirement — HVAC-R and service water heating equipment
NELSON LOPEZ
03/11/2025
Special inspection requirement — Heating Systems
NELSON LOPEZ
03/11/2025
Special inspection requirement — Final
NELSON LOPEZ
03/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
03/11/2025
Special inspection requirement — Shutoff dampers
NELSON LOPEZ
03/06/2025
Filed — Alteration
Remove existing fixtures. Replace various flushometers and faucets. Remove existing kitchen and science instruction room along with associated piping. Install new plumbing fixtures and related piping as per plans.
Q00716806-P9
02/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
02/26/2025
Special inspection requirement — Heating Systems
NELSON LOPEZ
02/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
NELSON LOPEZ
02/26/2025
Special inspection requirement — Mechanical Systems
NELSON LOPEZ
02/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
NELSON LOPEZ
02/26/2025
Special inspection requirement — Maintenance information
NELSON LOPEZ
02/26/2025
Special inspection requirement — Shutoff dampers
NELSON LOPEZ
02/26/2025
Special inspection requirement — Final
NELSON LOPEZ
02/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
NELSON LOPEZ
02/26/2025
Special inspection requirement — Ventilation and air distribution system
NELSON LOPEZ
06/24/2024
Permit issued — General Construction
Q00716806-I1-GC
06/20/2024
Permit issued — Structural
Q00716806-S1-ST
04/30/2024
Filed — Alteration
Remove existing fixtures. Replace various flushometers and faucets. Remove existing kitchen and science instruction room along with associated piping. Install new plumbing fixtures and related piping as per plans.
Q00716806-P4
04/29/2024
Violation issued (ECB, closed)
Construction
04/29/2024
Violation issued (ECB, closed)
Construction
04/29/2024
Violation issued (ECB, closed)
Construction
04/29/2024
Violation issued (ECB, closed)
Construction
04/22/2024
Filed — Alteration
Remove existing fixtures. Replace various flushometers and faucets. Remove existing kitchen and science instruction room along with associated piping. Install new plumbing fixtures and related piping as per plans.
Q00716806-P7
04/19/2024
Permit issued — Mechanical Systems
Q00716806-S2-MS
04/17/2024
Filed — Alteration
FILING FOR THE INSTALLATION OF EMERGENCY GENERATOR TO SERVE THE CONVENT BUILDING SEGMENT ONLY.
Q00739750-P1
11/14/2023
Violation issued (FDNY_NOV, closed)
10/10/2023
Permit issued — Plumbing
Q00716806-S3-PL
10/07/2023
Violation issued (FDNY_NOV, closed)
08/09/2023
Filed — Alteration
Remove existing fixtures. Replace various flushometers and faucets. Remove existing kitchen and science instruction room along with associated piping. Install new plumbing fixtures and related piping as per plans.
Q00716806-P6
Latest 60 of 144 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedACS SYSTEM ASSOCIATES INC.04/30/2026
DOB NOWGeneral ConstructionPermit IssuedNATIONAL ENVIROMENTAL SAF03/31/2026
DOB NOWPlumbingSigned-offMAR-SAL PLBG & HTG, INC09/26/2025
DOB NOWStructuralPermit IssuedNATIONAL ENVIROMENTAL SAF05/23/2025
DOB NOWMechanical SystemsPermit IssuedACS SYSTEM ASSOCIATES INC.04/30/2025
DOB NOWGeneral ConstructionPermit IssuedNATIONAL ENVIROMENTAL SAF06/24/2024
DOB NOWStructuralPermit IssuedNATIONAL ENVIROMENTAL SAF06/20/2024
DOB NOWMechanical SystemsPermit IssuedACS SYSTEM ASSOCIATES INC.04/19/2024
DOB NOWPlumbingSigned-offMAR-SAL PLBG & HTG, INC10/10/2023
DOB NOWBoiler EquipmentSigned-offJACK PICCINI, INC08/02/2023
DOB NOWMechanical SystemsPermit IssuedACS SYSTEM ASSOCIATES INC.07/05/2023
DOB NOWStructuralPermit IssuedNATIONAL ENVIROMENTAL SAF06/28/2023
DOB NOWGeneral ConstructionPermit IssuedNATIONAL ENVIROMENTAL SAF06/07/2023
DOB NOWMechanical SystemsSigned-offABC MADISON BUILDERS05/31/2023
DOB NOWPlumbingSigned-offMAR-SAL PLBG & HTG, INC10/03/2022
DOB NOWStructuralPermit IssuedNATIONAL ENVIROMENTAL SAF07/26/2022
DOB NOWPlumbingSigned-offMAR-SAL PLBG & HTG, INC07/19/2022
DOB NOWMechanical SystemsPermit IssuedACS SYSTEM ASSOCIATES INC.07/07/2022
DOB NOWGeneral ConstructionPermit IssuedNATIONAL ENVIROMENTAL SAF07/06/2022
DOB NOWSupported ScaffoldSigned-offPOLONIA DEVELOPMENT & PRE06/15/2020
DOB NOWBoiler EquipmentPermit IssuedRANSHAW PLBG & HTG LLC11/25/2019
BISOTISSUEDFAZIO CONSTRUCTION GROUP01/10/2020
BISFPISSUEDFIRE FOE SS CORP06/08/2005
BISFBISSUEDEDWARD T. MINOR CO. INC03/29/2004
BISPLISSUEDBYRNE & SONS INC04/05/1995
BISBLISSUEDBYRNE & SONS INC04/05/1995
1 project · most recent 08/25/2025
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/25/2025Permit IssuedACS SYSTEM ASSOCIATES INCAir Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
Daikin AC-1: FTX36NVJU ACCU-1: RX36NVMJUA 37,000 BTU · Heat Pump Outdoor ×6
AC-2: FTX36NVJU ACCU-2: RX36NMVJUA 37,000 BTU · Heat Pump Outdoor ×6
AC-3: FTX36NVJU ACCU-3: RX36NMVJUA 37,000 BTU · Heat Pump Outdoor ×6
Heat / Cool
Petra PPH-25 6,000 CFM · Rooftop Unit ×3
Ventilation
Greenheck G-095-G--1-17-X 350 CFM · Kitchen Exhaust ×6
G-200-B-20-1-30-X 4,000 CFM · Exhaust Fan ×6
G-300-C-50-1-40-X 11,240 CFM · Exhaust Fan ×6
GB-097-6-1-19-X 140 CFM · Exhaust Fan ×6
GB-140HP-7-1-22-X 1,260 CFM · Exhaust Fan ×6
CUBE-180HP-5-1-30 1,700 CFM · Kitchen Exhaust ×3
CUBE-240XP-30-1-34-6 2,550 CFM · Kitchen Exhaust ×3
G-095-D-8-1-17-X 300 CFM · Exhaust Fan ×3
G-097-A-4-1-19-X 150 CFM · Exhaust Fan ×3
GB-097-4-1-19-X 250 CFM · Exhaust Fan ×3
GB-098-6-1-19-X 350 CFM · Exhaust Fan ×3
GB-099-4-1-19-X 830 CFM · Exhaust Fan ×3
1 project · most recent 08/25/2025
Gas Water/Sanitary
FiledStatusContractorScope
08/25/2025Signed-offMAR-SAL PLBG & HTG, INCGas, Water/Sanitary
6 projects · most recent 03/04/2026
General Wiring HVAC Wiring
FiledStatusContractorScope
03/04/2026CompleteCHARAN ELEC'L ENTERP'S IN—
06/27/2022CompleteSTANCO SYSTEM ELEC'L CONTGeneral Wiring
04/27/2021Permit IssuedGEMINI ELECTRIC CO., INC.General Wiring
11/27/2019Permit IssuedV. VASS ELECTRIC CORP—
11/22/2019Permit IssuedPJZ MAINTENANCE CORP.General Wiring
04/15/2019Permit IssuedRF ELECTRIC COMPANY INCHVAC Wiring
1 project · most recent 08/25/2025
Steel Concrete
FiledStatusContractorScope
08/25/2025Permit IssuedACS SYSTEM ASSOCIATES INCSteel, Concrete
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/08/2023Pass-Final Boiler Equipment InspectionPassView ↗
12/29/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/18/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/12/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 81
DateRequirementInspectorRole
08/26/2025Energy Code Compliance InspectionsNELSON LOPEZprogress
08/26/2025Energy Code Compliance InspectionsNELSON LOPEZprogress
08/26/2025Maintenance informationNELSON LOPEZenergy_progress
08/26/2025HVAC-R and service water heating system controlsNELSON LOPEZenergy_progress
08/26/2025HVAC-R and service water heating equipmentNELSON LOPEZenergy_progress
08/26/2025Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
08/26/2025HVAC-R and service water heating equipmentNELSON LOPEZenergy_progress
08/26/2025HVAC-R and service water heating system controlsNELSON LOPEZenergy_progress
08/26/2025Maintenance informationNELSON LOPEZenergy_progress
08/26/2025Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
03/11/2025Maintenance informationNELSON LOPEZenergy_progress
03/11/2025HVAC-R and service water heating system controlsNELSON LOPEZenergy_progress
03/11/2025Ventilation and air distribution systemNELSON LOPEZenergy_progress
03/11/2025HVAC-R and service water heating equipmentNELSON LOPEZenergy_progress
03/11/2025Shutoff dampersNELSON LOPEZenergy_progress
03/11/2025Heating SystemsNELSON LOPEZspecial
03/11/2025Mechanical SystemsNELSON LOPEZspecial
03/11/2025Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
03/11/2025FinalNELSON LOPEZprogress
03/11/2025HVAC-R and service water piping design and insulationNELSON LOPEZenergy_progress
02/26/2025HVAC-R and service water heating equipmentNELSON LOPEZenergy_progress
02/26/2025Shutoff dampersNELSON LOPEZenergy_progress
02/26/2025FinalNELSON LOPEZprogress
02/26/2025Mechanical SystemsNELSON LOPEZspecial
02/26/2025Heating SystemsNELSON LOPEZspecial
Latest 25 of 81.
▾Documents — 164 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch16
08/26/2026Q00716806-S2Request digital key ↗
08/26/2026Q00716806-P4Request digital key ↗
08/26/2026Q00716806-P8Request digital key ↗
Showing 3 of 16 on file for this type
▸DOB NOWPlans/Sketch - Boiler Equipment2
08/28/2026Q00250302-I1Request digital key ↗
08/15/2026Q00250302-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
08/28/2026Q00354051-I1Request digital key ↗
▸Applications & Permits5
▸BISPLACE OF ASSEMBLY2
12/20/2018421927151Open ↗
12/20/2018421927231Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
11/12/2019421906003Open ↗
06/21/2017421416257Open ↗
▸BISWORK PERMIT APPLICATION1
01/16/2020421906003Open ↗
▸Seals & Professional Certifications102
▸DOB NOWProgress Inspector Seal & Signature48
09/26/2026Q00716806-P6Open ↗
09/26/2026Q00716806-P6Open ↗
09/23/2026Q00716806-P1Open ↗
Showing 3 of 48 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature28
09/26/2026Q00716806-P6Open ↗
09/23/2026Q00716806-P1Open ↗
09/23/2026Q00716806-P1Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature19
08/28/2026Q00250302-I1Open ↗
08/28/2026Q00250302-P1Open ↗
08/28/2026Q00354051-I1Open ↗
Showing 3 of 19 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
01/16/2020421906003Open ↗
11/12/2019421906003Open ↗
05/28/2019421927231Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/12/2019421906003Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
11/12/2019421906003Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
06/21/2017421416257Open ↗
▸BISTenant Protection Plan and Notes1
11/12/2019421906003Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/28/2026Q00250302-P1Open ↗
08/28/2026Q00250302-I1Open ↗
08/25/2026Q00739750-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/13/2026Q00716806-S3Open ↗
08/13/2026Q00716806-S1Open ↗
08/13/2026Q00716806-I1Open ↗
Showing 3 of 4 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
01/16/2020421906003Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
01/16/2020421906003Open ↗
11/12/2019421906003Open ↗
06/21/2017421416257Open ↗
▸DOB NOWEN2: As Built Energy Analysis2
08/26/2026Q00716806-S2Open ↗
08/26/2026Q00716806-S3Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
12/14/2020421906003Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/14/2020421906003Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00250302-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
12/15/2020421906003Open ↗
12/14/2020421906003Open ↗
▸Approvals, Objections & Sign-offs9
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
08/28/2026Q00250302-I1Open ↗
08/28/2026Q00250302-P1Open ↗
08/28/2026Q00354051-I1Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE1
06/21/2017421416257Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
06/21/2017421416257Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/17/2020421906003Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
12/14/2020421906003Open ↗
11/12/2019421906003Open ↗
06/21/2017421416257Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
11/12/2019421906003Open ↗
06/21/2017421416257Open ↗
▸BISADDITIONAL INFORMATION1
12/16/2020421906003Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
06/21/2017421416257Open ↗