← Back
BuildNYC
Condo, residential unit in elevator building
151 WEST 17TH STREET
MANHATTAN · BIN 1085965
💬 Discuss this project
2001Year Built
12Stories
R4Building Class
C6-2AZoning
108,969 sfGross Floor Area
50Units
LL97 CoveredRent Stabilized1 Active Violation ▸FISP: SAFE
Condo, residential unit in elevator building · 23,510 sf lot · 4.64 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofDouglas Elliman Property ManagementUnder Construction17p · 4 filings · 20 docs
Floor 12Unit 12F19p · 4 filings · 20 docs
Floor 1113p · 2 filings · 20 docs
Floor 10Unit 10G1 filing · 4 docs
Floor 9
Floor 8Unit 8GH36p · 4 filings · 20 docs
Floor 7
Floor 6
Floor 5
Floor 4Unit 4G4p · 1 filing · 7 docs
Floor 3Ent Allergy non-illuminated awning1p · 1 filing · 6 docs
Floor 2Unit 2C3p · 2 filings · 14 docs
Floor 1Unit 1D5p · 2 filings · 18 docs
Site & exteriorDouglas Elliman Property ManagementUnder Construction17p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
151 West 17 Street Condominium5003/21/2026
EL-AD Skyview1003/21/2026
EL-AD Group703/21/2026
151 West 17 Street603/21/2026
151 West 17th St403/21/2026
SRL Associates207/08/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Michael Zenreich Architect1003/21/2026
Tailwind Consultants603/21/2026
J Callahan Consulting1603/21/2026
Dina Vedmed Architect103/21/2026
Theresa Voltaggio303/21/2026
Louis Striar203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Reyes EnterpriseGeneral Contractor1007/08/2026
IA Construction ManagementGeneral Contractor607/08/2026
Van Gogh Paintersspecialty_contractor507/08/2026
Next Generation Restorationspecialty_contractor407/08/2026
Ket ElectricElectrical403/21/2026
Ket ElectricGeneral Contractor303/22/2026
Romo ConstructionScaffold303/21/2026
Ice Age Mechanicalspecialty_contractor303/21/2026
Anchor PlumbingFire Protection207/08/2026
Metrotech MechanicalPlumbing207/08/2026
Romo ConstructionGeneral Contractor207/08/2026
Anchor PlumbingPlumbing207/08/2026
Wawel Plumbing and HeatingPlumbing103/22/2026
Sato Construction CoGeneral Contractor107/08/2026
Vallesigns & Awningsspecialty_contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA Building & Inspection1519103/31/2026
Frame Design and Construction7971103/31/2026
Alan Margolin & Associates423612/08/2023
Shahrish Shuvo Engineering8524706/27/2023
Cowley Engineering186306/29/2022
Victor Schwartz Architect1714212/22/2021
Building Lifecycle
All (198)Filed (30)Permit Issued (31)Signed Off (14)Facade (FISP) (9)Violation (60)Inspection (10)Objection (14)Special Inspection (30)
07/21/2026
Signed off — Alteration
INITIAL CD5 INSPECTION & FISP REPAIRS PER PLANS NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01389038-I1
05/06/2026
Permit issued — Suspended Scaffold
M01389038-I1-SC
05/05/2026
Permit issued — General Construction
M01377811-I1-GC
04/24/2026
Objection raised — Other
04/24/2026
Objection resolved — Addressed
04/17/2026
Filed — Alteration
INITIAL CD5 INSPECTION & FISP REPAIRS PER PLANS NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01389038-I1
03/31/2026
Filed — Alteration
Exterior Facade repairs and waterproofing, pointing, parapet repairs
M01377811-I1
03/24/2026
Signed off — Alteration
M00734248-I1
03/17/2026
Signed off — Alteration
Application being filed for the interior renovation of existing Unit 12-F on 12th Floor as per plans filed herewith. No change in use, egress, or occupancy.
M00726639-I1
10/16/2025
Permit issued — General Construction
M00726639-I1-GC
10/16/2025
Permit issued — Mechanical Systems
M00734248-I1-MS
06/16/2025
Filed — Alteration
MINOR PARTITIONS WORK IN APARTMENT 10G. DEMO AND RECONSTRUCT A 2-HOUR FIRE-RATED PARTITION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01239370-I1
06/13/2025
Signed off — Alteration
Interior renovation in apartment 4G, to include removal and installation of partitions, doors, and finishes. No change to use. egress or occupancy is involved.
M00666903-I1
06/11/2025
Special inspection requirement — Final
BAILEY HECK
06/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/11/2025
Special inspection requirement — Fire-Resistance Rated Construction
06/10/2025
Permit issued — Mechanical Systems
M00734248-I1-MS
06/09/2025
Permit issued — General Construction
M00726639-I1-GC
01/13/2025
Permit issued — General Construction
M00726639-I1-GC
12/23/2024
Permit issued — Mechanical Systems
M00734248-I1-MS
11/22/2024
Signed off — Alteration
Replacement and relocation of plumbing fixtures
M00734259-I1
07/03/2024
Signed off — Alteration
FILING HEREWITH MODIFICATION OF MECHANICAL SYSTEM AS INDICATD ON THE DRAWINGS. NO CHANE IN USE EGRESS OR OCUPANCY
M00608559-I1
04/29/2024
Signed off — Alteration
MODIFICATION OF SPRINKLER SYSTEM ON THE 8TH FLOOR APT GH AS INDICATED ON DRAWING. NO CHANGE IN USE EGRESS OR OCCUPANCY..
M00607929-I1
04/29/2024
Signed off — Alteration
M00527435-I1
04/26/2024
Signed off — Alteration
FILING HEREWITH PLUMBING MODIFICATION AS INDICATED ON THE DRAWINGS. NO CHANGE IN SE EGRSS OR OCCUPANCY
M00608605-I1
04/15/2024
Permit issued — Plumbing
M00734259-I1-PL
04/11/2024
Permit issued — General Construction
M00726639-I1-GC
02/07/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/05/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/05/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/08/2024
Permit issued — Mechanical Systems
M00608559-I1-MS
12/21/2023
Permit issued — Mechanical Systems
M00734248-I1-MS
12/11/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Young Suh
12/11/2023
Special inspection requirement — Maintenance information
Young Suh
12/11/2023
Special inspection requirement — Final
John Guth
12/11/2023
Special inspection requirement — HVAC-R and service water heating equipment
Young Suh
12/11/2023
Special inspection requirement — HVAC-R and service water heating system controls
Young Suh
12/11/2023
Special inspection requirement — Mechanical Systems
Young Suh
12/08/2023
Filed — Alteration
FILING HEREWITH MODIFICATION OF MECHANICAL SYSTEM AS INDICATD ON THE DRAWINGS. NO CHANE IN USE EGRESS OR OCUPANCY
M00608559-P1
12/06/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/17/2023
Permit issued — General Construction
M00666903-I1-GC
11/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/11/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/11/2023
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
08/29/2023
Permit issued — General Construction
M00527435-I1-GC
07/07/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
06/27/2023
Filed — Alteration
Replacement and relocation of plumbing fixtures
M00734259-P2
06/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Objection raised — Scope
06/20/2023
Objection resolved — Addressed
06/14/2023
Filed — Alteration
Replacement and relocation of plumbing fixtures
M00734259-P1
06/13/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
05/19/2023
Permit issued — General Construction
M00666903-I1-GC
05/04/2023
Permit issued — Sprinklers
M00607929-I1-EW-SP
04/13/2023
Filed — Alteration
Application being filed for the interior renovation of existing Unit 12-F on 12th Floor as per plans filed herewith. No change in use, egress, or occupancy.
M00726639-P1
04/12/2023
Special inspection requirement — Fire-Resistance Rated Construction
Shahrish Shuvo
Latest 60 of 198 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSuspended ScaffoldSigned-offSato Construction Co05/06/2026
DOB NOWGeneral ConstructionPermit IssuedSato Construction Co05/05/2026
DOB NOWGeneral ConstructionSigned-offReyes Enterprise10/16/2025
DOB NOWMechanical SystemsSigned-offReyes Enterprise10/16/2025
DOB NOWMechanical SystemsSigned-offReyes Enterprise06/10/2025
DOB NOWGeneral ConstructionSigned-offReyes Enterprise06/09/2025
DOB NOWGeneral ConstructionSigned-offReyes Enterprise01/13/2025
DOB NOWMechanical SystemsSigned-offReyes Enterprise12/23/2024
DOB NOWPlumbingSigned-offMetrotech Mechanical04/15/2024
DOB NOWGeneral ConstructionSigned-offReyes Enterprise04/11/2024
DOB NOWMechanical SystemsSigned-offIA Construction Management01/08/2024
DOB NOWMechanical SystemsSigned-offReyes Enterprise12/21/2023
DOB NOWGeneral ConstructionSigned-offVan Gogh Painters11/17/2023
DOB NOWGeneral ConstructionSigned-offIA Construction Management08/29/2023
DOB NOWGeneral ConstructionSigned-offVan Gogh Painters05/19/2023
DOB NOWSprinklersSigned-offAnchor Plumbing05/04/2023
DOB NOWPlumbingSigned-offMetrotech Mechanical04/11/2023
DOB NOWGeneral ConstructionSigned-offReyes Enterprise04/07/2023
DOB NOWPlumbingSigned-offAnchor Plumbing02/22/2023
DOB NOWGeneral ConstructionSigned-offIA Construction Management09/02/2022
DOB NOWGeneral ConstructionSigned-offVan Gogh Painters05/20/2022
DOB NOWGeneral ConstructionSigned-offNext Generation Restoration05/13/2022
DOB NOWSprinklersSigned-offAnchor Plumbing04/25/2022
DOB NOWGeneral ConstructionSigned-offNext Generation Restoration04/14/2022
DOB NOWPlumbingSigned-offAnchor Plumbing02/28/2022
DOB NOWGeneral ConstructionSigned-offIA Construction Management01/19/2022
DOB NOWGeneral ConstructionSigned-offRomo Construction10/01/2021
DOB NOWSidewalk ShedSigned-offRomo Construction09/09/2021
DOB NOWGeneral ConstructionSigned-offRomo Construction09/03/2021
DOB NOWGeneral ConstructionSigned-offVallesigns & Awnings06/10/2021
DOB NOWMechanical SystemsSigned-offIce Age Mechanical05/11/2021
BISOTISSUEDRomo Construction08/10/2018
BISPLISSUEDStar Cities PLB & Heating05/17/2018
BISOTISSUEDEco Specialties05/08/2018
BISOTISSUEDAerial Design Build Services08/07/2017
BISPLISSUEDAqueduct Mechanical06/09/2017
BISOTISSUEDAerial Design Build Services06/02/2017
BISPLISSUEDKatan P & H03/14/2017
BISPLISSUEDHarold Headley Plumbing02/09/2017
BISSPISSUEDAriana Contracting01/20/2017
+ 41 more permits on file
1 project · most recent 02/13/2023
Water/Sanitary
FiledStatusContractorScope
02/13/2023——Water/Sanitary
9 projects · most recent 06/30/2025
General Wiring
FiledStatusContractorScope
06/30/2025CompleteKet ElectricGeneral Wiring
02/09/2024CompleteEnterprise Electrical Systems—
04/20/2023CompletePolyphase ElectricGeneral Wiring
06/15/2022CancelledBestco ElectricalGeneral Wiring
02/17/2022CompleteWarren Ostroff ElectricGeneral Wiring
02/17/2022CompleteWarren Ostroff Electric—
10/14/2021Permit IssuedHigh Quality Electric of—
05/31/2018CompleteAlef Electrical ContractingGeneral Wiring
03/01/2018CompleteEuropa Electric of NYGeneral Wiring
1 project · most recent 04/17/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
04/17/2026Signed-offSato Construction CoSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
02/07/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/05/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/05/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/06/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/11/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/11/2023Certified Sprinkler - SP - RoughingCertifiedView ↗
07/07/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/12/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 51
DateRequirementInspectorRole
06/11/2025FinalBAILEY HECKprogress
06/11/2025Fire-Resistant Penetrations and Joints—special
06/11/2025Fire-Resistance Rated Construction—progress
12/11/2023HVAC-R and service water piping design and insulationYoung Suhenergy_progress
12/11/2023Maintenance informationYoung Suhenergy_progress
12/11/2023FinalJohn Guthprogress
12/11/2023HVAC-R and service water heating equipmentYoung Suhenergy_progress
12/11/2023HVAC-R and service water heating system controlsYoung Suhenergy_progress
12/11/2023Mechanical SystemsYoung Suhspecial
06/30/2023Fire-Resistant Penetrations and JointsShahrish Shuvospecial
06/27/2023Fire-Resistant Penetrations and JointsShahrish Shuvospecial
06/13/2023Fire-Resistant Penetrations and JointsShahrish Shuvospecial
04/12/2023Fire-Resistance Rated ConstructionShahrish Shuvoprogress
04/12/2023Interior lighting powerShahrish Shuvoenergy_progress
04/12/2023Fire-Resistant Penetrations and JointsShahrish Shuvospecial
04/12/2023Post-installed AnchorsShahrish Shuvospecial
04/12/2023Energy Code Compliance InspectionsShahrish Shuvoprogress
04/12/2023FinalShahrish Shuvoprogress
02/07/2023Fire-Resistant Penetrations and JointsYoung Suhspecial
01/24/2023Sprinkler SystemsYoung Suhspecial
10/25/2022FinalPhilip Consalvoprogress
08/31/2022Sprinkler SystemsYoung Suhspecial
06/30/2022FinalEric Cowleyprogress
06/30/2022Post-installed AnchorsEric Cowleyspecial
06/30/2022Structural Stability – Alterations of existing buildingsEric Cowleyspecial
Latest 25 of 51.
▾Documents — 544 on file (BIS + DOB NOW)
▸Plans & Drawings29
▸DOB NOWPlans/Sketch29
09/03/2026M00517270-I1Request digital key ↗
09/03/2026M00545619-I1Request digital key ↗
09/03/2026M00545619-P2Request digital key ↗
Showing 3 of 29 on file for this type
▸Applications & Permits85
▸BISWORK PERMIT APPLICATION52
08/10/2018123384916Open ↗
05/17/2018123410004Open ↗
05/09/2018123410004Open ↗
Showing 3 of 52 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION32
07/09/2018123384916Open ↗
04/17/2018123410004Open ↗
12/11/2017140722494Open ↗
Showing 3 of 32 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
12/04/2013121134263Open ↗
▸Seals & Professional Certifications134
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION58
05/31/2019123410004Open ↗
05/31/2019123410004Open ↗
05/31/2019123410004Open ↗
Showing 3 of 58 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature28
09/03/2026M00545619-P2Open ↗
09/03/2026M00545619-P1Open ↗
09/03/2026M00545619-I1Open ↗
Showing 3 of 28 on file for this type
▸DOB NOWProgress Inspector Seal & Signature25
09/23/2026M00726639-P1Open ↗
09/02/2026M00608559-I1Open ↗
09/02/2026M00608559-I1Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/23/2026M00726639-P1Open ↗
09/23/2026M00726639-P1Open ↗
09/02/2026M00608559-I1Open ↗
Showing 3 of 13 on file for this type
▸BISAPPLICANT OWNER SIGNATURE4
12/11/2017140722494Open ↗
05/26/2017140647110Open ↗
05/16/2017140642302Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
07/09/2018123384916Open ↗
Showing 1 of 3 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/09/2018123384916Open ↗
▸Trade Schedules & Equipment40
▸BISSELF-CERT PLUMBING NOTICE21
06/02/2015140317333Open ↗
04/29/2015140317333Open ↗
10/15/2013120434271Open ↗
Showing 3 of 21 on file for this type
▸BISSCHEDULE B - PLUMBING12
12/11/2017140722494Open ↗
03/11/2015140317333Open ↗
Showing 2 of 12 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE5
04/17/2018123410004Open ↗
05/02/2017123023566Open ↗
06/24/2015122440475Open ↗
Showing 3 of 5 on file for this type
▸BISSPRINKLER INSP REPORT : FP-852
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Safety & Tenant Protection5
▸BISTenant Protection Plan and Notes3
07/09/2018123384916Open ↗
04/17/2018123410004Open ↗
10/02/2017140642302Open ↗
▸BISSTREET TREE CHECKLIST2
05/26/2017140647110Open ↗
Showing 1 of 2 on file for this type
▸Environmental & Asbestos47
▸DOB NOWOER: Notice to Proceed11
09/03/2026M00545619-P2Open ↗
09/03/2026M00545619-P1Open ↗
09/03/2026M00545619-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWOER: Notice of Satisfaction9
09/03/2026M00545619-I1Open ↗
09/02/2026M00734248-I1Open ↗
08/15/2026M00485857-I1Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED5
08/03/2018123384916Open ↗
10/02/2017140642302Open ↗
08/14/2015122440475Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
05/02/2017123023566Open ↗
06/24/2015122052982Open ↗
08/19/2014122062052Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/23/2026M01239370-I1Open ↗
08/13/2026M00517270-I1Open ↗
▸BISASBESTOS-EXEMPTION (ASB4)1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION1
05/30/2017123023566Open ↗
▸Energy Compliance35
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS16
05/09/2019123410004Open ↗
12/03/2018123384916Open ↗
07/09/2018123384916Open ↗
Showing 3 of 16 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS7
12/03/2018123384916Open ↗
03/30/2018123023566Open ↗
06/27/2017122052982Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWEN2: As Built Energy Analysis.6
08/15/2026M00485857-I1Open ↗
08/13/2026M00608559-I1Open ↗
08/13/2026M00527435-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
10/02/2017140642302Open ↗
05/17/2017140642302Open ↗
03/11/2015140317333Open ↗
▸BISTR8: Energy Code Progress Inspections2
10/10/2014122062052Open ↗
Showing 1 of 2 on file for this type
▸BISTECHNICAL REPORT: ENERGY1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
10/02/2017140642302Open ↗
05/17/2017140642302Open ↗
03/11/2015140317333Open ↗
▸Approvals, Objections & Sign-offs65
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST26
05/31/2019123410004Open ↗
12/03/2018123384916Open ↗
03/30/2018123023566Open ↗
Showing 3 of 26 on file for this type
▸BISADMINISTRATIVE OBJECTIONS13
06/24/2015122052982Open ↗
Showing 1 of 13 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION12
05/31/2019123410004Open ↗
12/03/2018123384916Open ↗
12/26/2017140642302Open ↗
Showing 3 of 12 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE10
07/24/2014121134263Open ↗
07/24/2014121134263Open ↗
07/14/2014121134263Open ↗
Showing 3 of 10 on file for this type
▸BISLETTERS - APPROVED FABRICATION CERTIFICATIONS2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSUPERSEDING LETTER1
01/24/2017122062052Open ↗
▸BISLetter from Homeowner for Withdrawal1
12/26/2017140647110Open ↗
▸Cost, Insurance & Ownership48
▸BISCOST AFFIDAVIT44
05/31/2019123410004Open ↗
12/03/2018123384916Open ↗
07/09/2018123384916Open ↗
Showing 3 of 44 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT4
07/28/2015122052982Open ↗
Showing 1 of 4 on file for this type
▸Filing & Intake Forms40
▸BISEFILING COVER SHEET17
07/09/2018123384916Open ↗
04/17/2018123410004Open ↗
05/02/2017123023566Open ↗
Showing 3 of 17 on file for this type
▸BISADDITIONAL INFORMATION10
10/02/2017140642302Open ↗
07/19/2017140642302Open ↗
06/05/2017123023566Open ↗
Showing 3 of 10 on file for this type
▸BISBOROUGH INTAKE FORM7
05/31/2019123410004Open ↗
12/03/2018123384916Open ↗
05/17/2018123410004Open ↗
Showing 3 of 7 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET5
12/11/2017140722494Open ↗
05/26/2017140647110Open ↗
05/16/2017140642302Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWAI1 Form (from plan PDF)1
08/16/2026M00485857-P1Open ↗
▸Other Documents13
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION8
12/03/2018123384916Open ↗
07/17/2017122052982Open ↗
06/21/2017122052982Open ↗
Showing 3 of 8 on file for this type
▸BISDepartment of Consumer Affairs (DCA) Form1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISENVIRONMENTAL 'E' DEP NOTICE TO PROCEED1
09/13/2013121745255Open ↗
▸BISSupporting Document: Fee Exempt1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWCalculations1
08/13/2026M01389038-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026M01389038-I1Open ↗