← Back
Walk-up apt, over six families with stores
One Lincoln Square Condominium
152 COLUMBUS AVENUE · BIN 1028842
💬 Discuss this project
1910Year Built
5Stories
C7Building Class
C4-7Zoning
9,250 sfGross Floor Area
13Units
Rent Stabilized1 Open Violation ▸
Walk-up apt, over six families with stores · Owner of record: 148-154 COLUMBUS REALTY I, LLC · 2,500 sf lot · 3.7 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof1p · 1 filing · 3 docs
Floor 51p · 1 filing · 3 docs
Floor 41p · 1 filing · 3 docs
Floor 31p · 1 filing · 3 docs
Floor 21p · 1 filing · 3 docs
Floor 12p · 2 filings · 10 docs
Cellar11p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
148-154 COLUMBUS REALTY I LLC3007/08/2026
MILLENNIUM PARTNERS703/22/2026
OUTDOOR INSTALLATIONS LLC103/21/2026
148-154V COLUMBUS REALTY 1403/21/2026
148-54 COLUMBUS REALTY 1 LLC203/21/2026
COOPER SQUARE REALTY1003/21/2026
ONE LINCOLN SQUARE CONDOMINIUM503/21/2026
148-154 COLUMBUS AVE1003/21/2026
ACCORD REALTY1003/21/2026
MILLENNIUM203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TAN ENGINEERING PC301/10/2022
NDNY ARCHITECTURE + DESIGN PLLC111/09/2021
KDV DESIGNS ARCHITECTS LLC111/08/2021
SKYLINE ENGINEERING, LLC110/26/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MUNICIPAL BUILDING CONSULTANTS403/21/2026
TBC & ASSOC.203/21/2026
KNA CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FRANKLYLOFTY CONSTRUCTIONGeneral Contractor303/21/2026
MASTER FIRE MECH CORPGeneral Contractor303/21/2026
PEREIRA, WESLLEYElectrical203/21/2026
HERNAN SOCARRASElectrical203/21/2026
COOPER WORKS INCGeneral Contractor207/08/2026
ALPHONSE, MICHAELElectrical203/21/2026
MICHAEL D'ANNUNZIOElectrical103/21/2026
NORMAN TCHERNOFFElectrical103/21/2026
PAGANO, DONALDElectrical103/21/2026
VITO INGRAVALLOElectrical103/21/2026
ACCURATE MECHANICAL INCPlumbing107/08/2026
D'ANNUNZIO MICHAELElectrical103/21/2026
DONALD PAGANOElectrical103/21/2026
ERNEST JOCHENElectrical103/21/2026
JESUS CORPORANElectrical103/21/2026
JOHN JR MARIElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TAN ENGINEERING, P.C.1291301/10/2022
SKYLINE ENGINEERING, PLLC267311/08/2021
Building Lifecycle
All (92)Filed (6)Permit Issued (5)Signed Off (4)Violation (60)Inspection (4)Special Inspection (13)
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/01/2024
Violation issued (HPD, closed)
A
11/15/2023
Violation issued (HPD, closed)
I
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/15/2023
Violation issued (HPD, closed)
A
11/02/2022
Violation issued (HPD, closed)
I
04/28/2022
Signed off — Alteration
INTERIOR RENOVATIONS FOR THE RETAIL SPACE AT THE CELLAR AND 1ST FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00625057-I1
04/27/2022
Signed off — Alteration
REMOVE & INSTALL NEW PLUMBING FIXTURES, INSTALLATION OF NEW SPRINKLERS OFF DOMESTIC CW LINE. INSTALL COMMERCIAL COOKING EQUIPMENT(ELECTRIC) FOR THE RETAIL SPACE AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00619649-I1
04/27/2022
Signed off — Alteration
M00619653-I1
04/12/2022
Signed off — Alteration
INSTALL NEW KITCHEN EXHAUST DUCT PENETRATION THROUGH EXTERIOR BRICK WALL. NO CHANGE TO USE, EGRESS OR OCCUPANCY
M00607509-I1
03/04/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/02/2022
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
01/18/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/11/2022
Permit issued — Mechanical Systems
M00619653-I1-MS
01/10/2022
Filed — Alteration
REMOVE & INSTALL NEW PLUMBING FIXTURES, INSTALLATION OF NEW SPRINKLERS OFF DOMESTIC CW LINE. INSTALL COMMERCIAL COOKING EQUIPMENT(ELECTRIC) FOR THE RETAIL SPACE AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00619649-P1
01/04/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Roger Tan
01/04/2022
Special inspection requirement — Energy Code Compliance Inspections
Roger Tan
01/04/2022
Special inspection requirement — HVAC-R and service water heating equipment
Roger Tan
01/04/2022
Special inspection requirement — HVAC-R and service water heating system controls
Roger Tan
12/28/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/15/2021
Permit issued — Plumbing
M00619649-I1-PL
11/29/2021
Permit issued — Structural
M00607509-I1-ST
11/26/2021
Permit issued — Mechanical Systems
M00624113-I1-MS
11/24/2021
Permit issued — General Construction
M00625057-I1-GC
11/17/2021
Filed — Alteration
REMOVE & INSTALL NEW PLUMBING FIXTURES, INSTALLATION OF NEW SPRINKLERS OFF DOMESTIC CW LINE. INSTALL COMMERCIAL COOKING EQUIPMENT(ELECTRIC) FOR THE RETAIL SPACE AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00619649-I1
11/17/2021
Filed — Alteration
M00619653-I1
11/09/2021
Filed — Alteration
INTERIOR RENOVATIONS FOR THE RETAIL SPACE AT THE CELLAR AND 1ST FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00625057-I1
11/08/2021
Filed — Alteration
M00624113-I1
11/04/2021
Special inspection requirement — Energy Code Compliance Inspections
Young Suh
11/04/2021
Special inspection requirement — Final
MARY CHANDRAHASAN
11/04/2021
Special inspection requirement — Interior lighting power
Young Suh
11/04/2021
Special inspection requirement — Metering
Young Suh
10/26/2021
Filed — Alteration
INSTALL NEW KITCHEN EXHAUST DUCT PENETRATION THROUGH EXTERIOR BRICK WALL. NO CHANGE TO USE, EGRESS OR OCCUPANCY
M00607509-I1
10/06/2021
Special inspection requirement — Structural Steel - Welding
Matthew Wavro
10/06/2021
Special inspection requirement — Masonry
Matthew Wavro
10/06/2021
Special inspection requirement — Structural Steel - Details
Matthew Wavro
10/06/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Matthew Wavro
10/06/2021
Special inspection requirement — Final
Matthew Wavro
04/01/2021
Violation issued (HPD, closed)
A
10/24/2016
Violation issued (HPD, closed)
I
07/27/2016
Violation issued (HPD, closed)
B
07/27/2016
Violation issued (HPD, closed)
B
07/27/2016
Violation issued (HPD, closed)
A
07/27/2016
Violation issued (HPD, closed)
B
03/19/2009
Violation issued (HPD, closed)
B
03/19/2009
Violation issued (HPD, closed)
B
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/27/2007
Violation issued (ECB, closed)
Unknown
11/20/2007
Violation issued (ECB, closed)
Construction
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Latest 60 of 92 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCOOPER WORKS01/11/2022
DOB NOWPlumbingSigned-offANTHONY DISABATO12/15/2021
DOB NOWStructuralSigned-offFRANKLYLOFTY CONSTRUCTION11/29/2021
DOB NOWMechanical SystemsPermit IssuedMASTER FIRE MECH CORP11/26/2021
DOB NOWGeneral ConstructionSigned-offCOOPER WORKS11/24/2021
BISOTISSUEDPRC MAINTENANCE SVCS LLC06/09/2016
BISPLISSUEDSUPERB PLUMBING & HEATING04/11/2016
BISOTISSUEDPRC MAINTENANCE SVCS LLC04/01/2016
BISPLISSUEDZ.W. PLBG & HTG CORP10/27/2014
BISOTISSUEDPRC MAINTENANCE SVCS LLC09/19/2014
BISOTISSUEDPEGASUS REALTY SOLUTIONS07/09/2013
BISEQISSUEDROCKLEDGE SCAFFOLD CORP06/28/2013
BISPLISSUEDCLEAN TECH MECHANICAL INC05/07/2013
BISEQISSUEDYATES REST GROUP LTD02/07/2013
BISOTISSUEDYATES REST GROUP LTD02/07/2013
BISEQISSUEDYATES REST GROUP LTD02/07/2013
BIS—ISSUEDACTIVE SIGNS INC12/04/2012
BIS—ISSUEDACTIVE SIGNS INC12/04/2012
BISPLISSUEDSHAW MECHANICAL INC09/19/2012
BISEQISSUEDYATES REST GROUP LTD09/12/2012
BISEQISSUEDYATES REST GROUP LTD09/12/2012
BISOTISSUEDYATES REST GROUP LTD08/21/2012
BISOTISSUEDW.J. REGAN & COMPANY LLC08/06/2012
BISEQISSUEDROCKLEDGE SCAFFOLD CORP07/26/2012
BISEQISSUEDROCKLEDGE SCAFFOLD CORP11/23/2011
BISPLISSUEDMARATHON MECHANICAL LLC07/07/2011
BISOTISSUEDCUSTOM INTERIORS BY JBI I06/17/2011
BISBLISSUEDACE-ATLAS PLBING & HTG03/23/2009
BISPLISSUEDACE-ATLAS PLBING & HTG03/23/2009
BISEQISSUEDOUTDOOR INSTALLATION LLC10/21/2008
BISEQISSUEDOUTDOOR INSTALLATION LLC10/17/2008
BISOTISSUEDJAP RESTORATION INC09/11/2008
BISOTISSUEDDJM RESTORATION, INC.04/16/2008
BISPLISSUEDHANRATTY PLUMBING SERVICE INC.12/27/2007
BISOTRE-ISSUEDQUANTTUM GENERAL CONTRACTING INC12/26/2007
BISEQISSUEDOUTDOOR INSTALLATIONS LLC11/29/2007
BISOTISSUEDDJM RESTORATION, INC.08/10/2007
BISEQISSUEDOUTDOOR INSTALLATIONS LLC12/08/2006
BISBLISSUEDACE-ATLAS PLBING & HTG10/17/2006
BISPLISSUEDACCURATE MECHANICAL INC06/28/2006
+ 15 more permits on file
2 projects · most recent 07/07/2022
General Wiring
FiledStatusContractorScope
07/07/2022CompleteGALAXY ELECTRIC CORPGeneral Wiring
03/30/2022CompleteHESO ELECTRICAL INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/04/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/02/2022Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
01/18/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/28/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
01/04/2022Fire-Resistant Penetrations and JointsRoger Tanspecial
01/04/2022Energy Code Compliance InspectionsRoger Tanprogress
01/04/2022HVAC-R and service water heating equipmentRoger Tanenergy_progress
01/04/2022HVAC-R and service water heating system controlsRoger Tanenergy_progress
11/04/2021Energy Code Compliance InspectionsYoung Suhprogress
11/04/2021FinalMARY CHANDRAHASANprogress
11/04/2021Interior lighting powerYoung Suhenergy_progress
11/04/2021MeteringYoung Suhenergy_progress
10/06/2021Structural Steel - WeldingMatthew Wavrospecial
10/06/2021MasonryMatthew Wavrospecial
10/06/2021Structural Steel - DetailsMatthew Wavrospecial
10/06/2021Structural Stability – Alterations of existing buildingsMatthew Wavrospecial
10/06/2021FinalMatthew Wavroprogress
▾Documents — 262 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/03/2026M00607509-I1Request digital key ↗
09/03/2026M00624113-I1Request digital key ↗
09/03/2026M00625057-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits61
▸BISPLAN / WORK APPROVAL APPLICATION39
04/05/2023121175682Open ↗
04/03/2023121175682Open ↗
03/17/2023121175682Open ↗
Showing 3 of 39 on file for this type
▸BISWORK PERMIT APPLICATION22
06/14/2016122647403Open ↗
04/18/2016122647403Open ↗
04/11/2016122647403Open ↗
Showing 3 of 22 on file for this type
▸Seals & Professional Certifications68
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION28
01/27/2020102087073Open ↗
01/27/2020102087073Open ↗
01/11/2016122647403Open ↗
Showing 3 of 28 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST11
01/11/2016122647403Open ↗
09/30/2014122137428Open ↗
12/05/2012121449174Open ↗
Showing 3 of 11 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM9
12/05/2012121449174Open ↗
12/05/2012121449183Open ↗
09/14/2012121375056Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
09/03/2026M00624113-I1Open ↗
09/03/2026M00619649-I1Open ↗
09/03/2026M00619649-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
08/31/2026M00625057-I1Open ↗
08/31/2026M00625057-I1Open ↗
08/31/2026M00625057-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/25/2026M00619649-P1Open ↗
08/23/2026M00607509-I1Open ↗
08/23/2026M00607509-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
01/11/2016122647403Open ↗
09/30/2014122137428Open ↗
▸BISPC FULL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment21
▸BISSELF-CERT PLUMBING NOTICE8
03/25/2015122137428Open ↗
01/29/2015122137428Open ↗
01/20/2015122137428Open ↗
Showing 3 of 8 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
10/19/2016122647403Open ↗
01/11/2016122647403Open ↗
01/11/2016122647403Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING5
08/08/2012121175682Open ↗
06/23/2011120727008Open ↗
03/09/2010120286467Open ↗
Showing 3 of 5 on file for this type
▸BISSIGN HANGER CERTIFICATE2
12/06/2012121449174Open ↗
12/06/2012121449183Open ↗
▸Safety & Tenant Protection1
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
09/14/2012121375056Open ↗
▸Environmental & Asbestos24
▸BISASBESTOS-CERTIFICATION (DEP ACP5)8
12/05/2012121449174Open ↗
12/05/2012121449183Open ↗
06/23/2011120727008Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER7
09/14/2012121372433Open ↗
11/28/2011120904469Open ↗
03/09/2010120286467Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
09/03/2026M00624113-I1Open ↗
09/03/2026M00619649-I1Open ↗
09/03/2026M00619649-P1Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISASBESTOS-EXEMPTION (ASB4)1
07/30/2012121152821Open ↗
▸Energy Compliance12
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
01/11/2016122647403Open ↗
10/17/2015122137428Open ↗
10/17/2015122137428Open ↗
Showing 3 of 5 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
10/17/2015122137428Open ↗
09/25/2015122137428Open ↗
07/20/2015122137428Open ↗
▸DOB NOWEN2: As Built Energy Analysis.3
09/03/2026M00619649-I1Open ↗
08/13/2026M00625057-I1Open ↗
08/13/2026M00619653-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY1
06/23/2011120727008Open ↗
▸Approvals, Objections & Sign-offs32
▸BISADMINISTRATIVE OBJECTIONS15
12/05/2012121449183Open ↗
12/05/2012121449174Open ↗
09/14/2012121375056Open ↗
Showing 3 of 15 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
04/06/2023121175682Open ↗
01/27/2020102087073Open ↗
10/17/2015122137428Open ↗
Showing 3 of 9 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION6
01/03/2020102087073Open ↗
08/02/2013120727008Open ↗
07/09/2013121152821Open ↗
Showing 3 of 6 on file for this type
▸BISCCD1-Construction Code Determination1
10/16/2012121163686Open ↗
▸BISFINAL1
12/27/2022121175682Open ↗
▸Cost, Insurance & Ownership14
▸BISCOST AFFIDAVIT12
09/25/2015122137428Open ↗
07/20/2015122137428Open ↗
09/30/2014122137428Open ↗
Showing 3 of 12 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
11/14/2022121175682Open ↗
▸BISHIC LICENSE OR AFFIDAVIT1
06/21/2011120727008Open ↗
▸Filing & Intake Forms22
▸BISEFILING COVER SHEET15
01/11/2016122647403Open ↗
09/30/2014122137428Open ↗
12/05/2012121449174Open ↗
Showing 3 of 15 on file for this type
▸BISADDITIONAL INFORMATION5
03/14/2023121175682Open ↗
05/17/2016122647403Open ↗
10/04/2012121152821Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM2
01/27/2020102087073Open ↗
12/30/2019102087073Open ↗
▸Other Documents1
▸BISDepartment of Consumer Affairs (DCA) Form1
08/07/2012121175682Open ↗