← Back
Five to six families
1536 DEKALB AVENUE
BROOKLYN · Bushwick (West) · BIN 3073878
💬 Discuss this project
1931Year Built
3Stories
C2Building Class
R6Zoning
5,100 sfGross Floor Area
6Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Five to six families · Owner of record: 1536 DEKALB AVE LLC · 2,500 sf lot · 2.04 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 32p · 1 filing · 20 docs
Floor 22p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
1536 DEKALB AVE LLC103/22/2026
1536 DEKALB LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/02/2018$1.2M—— → —$245/sf building
07/07/2016$1.2M—Private party → 1536 DEKALB, LLC$245/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LONGTIN SOLUTIONS LLC602/07/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
METHOD GENERAL CONTRACTORGeneral Contractor303/21/2026
S&R ELECTRICAL & MECHANICElectrical103/22/2026
P.H. WORKS INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LONGTIN SOLUTIONS LLC8320602/07/2023
Building Lifecycle
All (56)Filed (6)Permit Issued (2)Signed Off (2)Violation (9)Inspection (7)Special Inspection (30)
11/20/2025
Violation issued (HPD, closed)
I
10/29/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/09/2025
Violation issued (HPD, closed)
A
03/03/2023
Signed off — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK IN CONJUNCTION WITH OT JOB# B00771082-I1. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00771102-I1
02/28/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
02/27/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/07/2023
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK IN CONJUNCTION WITH OT JOB# B00771082-I1. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00771102-P3
02/07/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
TIM TSAI
02/07/2023
Special inspection requirement — Energy Code Compliance Inspections
TIM TSAI
02/03/2023
Special inspection requirement — Energy Code Compliance Inspections
TIM TSAI
02/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
TIM TSAI
01/10/2023
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK IN CONJUNCTION WITH OT JOB# B00771082-I1. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00771102-P2
01/10/2023
Signed off — Alteration
PROPOSED INTERIOR RENOVATION OF EXISTING CELLAR, 1ST,2ND,3RD FLOORS. CONSTRUCTION AND MECHANICAL WORK AS PER PLAN. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B00771082-I1
01/09/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
01/05/2023
Special inspection requirement — Energy Code Compliance Inspections
TIM TSAI
01/05/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
TIM TSAI
01/03/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/04/2022
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
09/16/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/15/2022
Special inspection requirement — Fenestration areas
TIM TSAI
09/15/2022
Special inspection requirement — Mechanical Systems
TIM TSAI
09/15/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
TIM TSAI
09/15/2022
Special inspection requirement — Energy Code Compliance Inspections
TIM TSAI
09/15/2022
Special inspection requirement — Fire-Resistance Rated Construction
TIM TSAI
09/15/2022
Special inspection requirement — Final
TIM TSAI
09/15/2022
Special inspection requirement — Maintenance information
TIM TSAI
09/15/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
TIM TSAI
09/15/2022
Special inspection requirement — HVAC-R and service water heating system controls
TIM TSAI
09/15/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
TIM TSAI
09/15/2022
Special inspection requirement — Interior lighting power
TIM TSAI
09/15/2022
Special inspection requirement — HVAC-R and service water heating equipment
TIM TSAI
09/14/2022
Filed — Alteration
PROPOSED INTERIOR RENOVATION OF EXISTING CELLAR, 1ST,2ND,3RD FLOORS. CONSTRUCTION AND MECHANICAL WORK AS PER PLAN. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B00771082-P1
09/14/2022
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK IN CONJUNCTION WITH OT JOB# B00771082-I1. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00771102-P1
07/18/2022
Permit issued — Plumbing
B00771102-I1-PL
07/12/2022
Permit issued — Mechanical Systems
B00771082-I1-GC-CX
07/11/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
TIM TSAI
07/11/2022
Special inspection requirement — Energy Code Compliance Inspections
TIM TSAI
07/11/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
TIM TSAI
07/11/2022
Special inspection requirement — Fenestration areas
TIM TSAI
07/11/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
TIM TSAI
07/11/2022
Special inspection requirement — Interior lighting power
TIM TSAI
07/11/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
TIM TSAI
07/11/2022
Special inspection requirement — Maintenance information
TIM TSAI
07/11/2022
Special inspection requirement — HVAC-R and service water heating equipment
TIM TSAI
07/11/2022
Special inspection requirement — HVAC-R and service water heating system controls
TIM TSAI
07/11/2022
Special inspection requirement — Fire-Resistance Rated Construction
TIM TSAI
07/11/2022
Special inspection requirement — Final
TIM TSAI
07/08/2022
Filed — Alteration
SUBSEQUENT FILING FOR PLUMBING WORK IN CONJUNCTION WITH OT JOB# B00771082-I1. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00771102-I1
07/08/2022
Filed — Alteration
PROPOSED INTERIOR RENOVATION OF EXISTING CELLAR, 1ST,2ND,3RD FLOORS. CONSTRUCTION AND MECHANICAL WORK AS PER PLAN. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B00771082-I1
02/24/2022
Violation issued (HPD, closed)
A
10/23/2017
Violation issued (ECB, closed)
Boilers
11/04/2016
Violation issued (HPD, closed)
I
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offP.H. WORKS INC07/18/2022
DOB NOWMechanical SystemsSigned-offMETHOD GENERAL CONTRACTOR07/12/2022
1 project · most recent 09/14/2022
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/14/2022Signed-offMETHOD GENERAL CONTRACTORAir Conditioning Systems
Cooling
Mitsubishi Electric MXZ-GE06NA-8 6,000 BTU · Vrf Outdoor ×20
MXZ-GE12NA-8 12,000 BTU · Fan Coil Indoor ×10
MXZ-4C36NA2 35,400 BTU · Condensing Unit ×6
1 project · most recent 01/05/2023
General Wiring
FiledStatusContractorScope
01/05/2023CompleteS&R ELECTRICAL & MECHANICGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
02/28/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
02/27/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/09/2023Pass-Final General Construction Non-Directive 14PassView ↗
01/03/2023Fail-Final General Construction Non-Directive 14FailView ↗
11/04/2022Pass-Final PL - Up to 9 Requested FloorsPassView ↗
09/16/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
02/07/2023Fire-Resistant Penetrations and JointsTIM TSAIspecial
02/07/2023Energy Code Compliance InspectionsTIM TSAIprogress
02/03/2023Energy Code Compliance InspectionsTIM TSAIprogress
02/03/2023Fire-Resistant Penetrations and JointsTIM TSAIspecial
01/05/2023Energy Code Compliance InspectionsTIM TSAIprogress
01/05/2023Fire-Resistant Penetrations and JointsTIM TSAIspecial
09/15/2022Fenestration areasTIM TSAIenergy_progress
09/15/2022Mechanical SystemsTIM TSAIspecial
09/15/2022Fire-Resistant Penetrations and JointsTIM TSAIspecial
09/15/2022Energy Code Compliance InspectionsTIM TSAIprogress
09/15/2022Fire-Resistance Rated ConstructionTIM TSAIprogress
09/15/2022FinalTIM TSAIprogress
09/15/2022Maintenance informationTIM TSAIenergy_progress
09/15/2022Fenestration and door U-factor and product ratingsTIM TSAIenergy_progress
09/15/2022HVAC-R and service water heating system controlsTIM TSAIenergy_progress
09/15/2022HVAC-R and service water piping design and insulationTIM TSAIenergy_progress
09/15/2022Interior lighting powerTIM TSAIenergy_progress
09/15/2022HVAC-R and service water heating equipmentTIM TSAIenergy_progress
07/11/2022Fire-Resistant Penetrations and JointsTIM TSAIspecial
07/11/2022Energy Code Compliance InspectionsTIM TSAIprogress
07/11/2022Fire-Resistant Penetrations and JointsTIM TSAIspecial
07/11/2022Fenestration areasTIM TSAIenergy_progress
07/11/2022Fenestration and door U-factor and product ratingsTIM TSAIenergy_progress
07/11/2022Interior lighting powerTIM TSAIenergy_progress
07/11/2022HVAC-R and service water piping design and insulationTIM TSAIenergy_progress
Latest 25 of 32.
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/29/2026B00771082-I1Request digital key ↗
08/29/2026B00771082-P1Request digital key ↗
08/28/2026B00771102-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications20
▸DOB NOWProgress Inspector Seal & Signature8
09/23/2026B00771102-P1Open ↗
09/01/2026B00771102-P2Open ↗
08/30/2026B00771082-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/29/2026B00771082-P1Open ↗
08/29/2026B00771082-I1Open ↗
08/28/2026B00771102-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026B00771102-P1Open ↗
09/01/2026B00771102-P2Open ↗
08/30/2026B00771082-P1Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/29/2026B00771082-P1Open ↗
08/29/2026B00771082-I1Open ↗
08/28/2026B00771102-I1Open ↗
Showing 3 of 6 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/29/2026B00771082-I1Open ↗