ECB08/24/2026AT TIME OF INSPECTION, UPON REVIEW OF DOB RECORDS, OBSERVED A SUPPORTED PIPE SCAFFOLD ERECTED AT EXP1 40 FEET OR HIGHER ALONG THE SEVEN-STORY BUILDING WITHOUT THE REQUIRED PERMIT.STOP ALL FACADE AND EXTERIOR WO$5K due
DOB07/02/2026EMERGENCY WORK ORDER DUE TO CRACKED/SPALLING DECORATE STONE @ NE & NW ENDS. TOP FL/LVL @ EXP1N,MULT LOC. II DEFECTIVE BALCONY RAILING @ TOP FL ALSO @1N. REMEDY:IMMEDIATELY TAKE/PROVIDE ADEQUATE SAFETY MEASURE TO SECURE/PROTECT PUBLIC & INSTALL PUBLIC PROTECTION. REPAIRS TO DEFECTIVE FACADE CONDITIONS U/FULL SUPV OF NYS LICENSED PROFESSIONAL
ECB02/20/2026FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SHED,NETTING,ETC.WHERE REQUIRED TO PROTECT PUBLIC AND PROPERTY FROM DOCUMENTED UNSAFE FACADE AS PER 1RCNY 103-04.FISP 3 NOTIFICATION REPORT FILED AS UNSAFE BY$12K due
ECB02/06/2026OBSERVED SECTION OF STONE SPAWLING FROM EXPOSURE 2 SIDE OF BUILDING AT 3 FLOOR AND 7 FLOOR OF BUILDING, MAINTAIN EXTERIOR BUILDING WALL$12K due
ECB10/09/2025FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER; OBSERVED EXPOSURE 1 FACADE IN STATE OF DISREPAIR. MISSING PIECES/DISPLACED STONE AND MORTAR JOINTS AT MINI COLUMN STRUCTURE AT ROOF. IN ADDITION THERE IS A$8K due
DOB07/15/2025EWO,HAZARDOUS CONDITION OF FIRE ESCAPE(FE) AT EXP3 SOUTH ELEV. REMEDY: IMMED REPAIR FE.IMMED PROVIDE AN APPROPRAITE # OF F-01 FIRE GUARD TO REMAIN AT LOCATION 24/7 TIL REPAIRARE COMPLETE & SIGN BY PE. PE TO PROVIDE PREMLIMARY INSPECT REPORT ON ALL FE BEFORE WORK BEGINS PE MUST SUBMIT REPORT TO FACADE@BUILDING.NYC.GOV. DONE UNDER F/T NYS LICEN PE
ECB06/19/2025FAILURE TO MAINTAIN BUILDING WALL. AT TIME OF INSPECTION, THERE IS STONE BLOCK WITH MISSING MORTAR JOINT AT EXPOSURE 1. IN ADDITION, THERE PARAPET WALL AT EXPOSURE 4 IN PARTIALLY LEANING., MAINTAIN EXTERIOR BUI$25K due
DOB06/19/2025REQUESTING AN ENGINEER REPORT DUE TO A SECTION OF FACADE COLLAPSING ONTO PUBLIC SIDEWALK WAT EXPOSURE#4. AN ENGINEERING REPORT IS REQUIRED TO ASSESS AND RECTIFY THE DAMAGES PROPERTY HAS SUSTAINED.
DOB02/22/2024FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
DOB06/01/2016FAILURE TO PERFORM CATEGORY 5 INSPECTION
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
DOB12/31/2013FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013
DOB12/13/2011VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
DOB10/08/2010V-DOB VIOLATION - ACTIVE
DOB03/31/2008V-DOB VIOLATION - ACTIVE
DOB11/30/2007V-DOB VIOLATION - ACTIVE
DOB08/08/2002V-DOB VIOLATION - ACTIVE
DOB01/13/1997V-DOB VIOLATION - ACTIVE
ECB07/02/2026FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SHED, NETTING ETC.WHERE REQUIRED TO PROTECT PUBLIC AND PROPERTY FROM DOCUMENTED UNSAFE FACADE AS PER 1 RCNY 103-04.-FACADE AS PER 1 RCNY 103-04.-FACADE TECHNIHearing held — result not yet published$25K proposed
ECB06/01/2017FAILURE TO MAINTAIN EXTERIOR BLDG FACADE AND APPURTENANCES.NOTE: I OBSERVED ON EXP1 NORTH ELEVATION:CRACKS AND SPALLING STUCCO AT THE NORTH EAST CORNER OF THE 7TH FLOOR: VERTICAL CRACK AT THE NORTH WEST EDGE OFNothing owed — awaiting certificate of correction
ECB08/02/2010FAILURE TO FILE AN ARCHITECT/ENGINEER REPORT CERTIFYING EXIT/DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURCE/STORAGE BATTERY EQUIPMENT.REM:FILE ARCHITECT/ENGINEER REPORTNothing owed — awaiting certificate of correction
ECB11/03/20062X10/11I10/38O2/85M5/40I10:(2)EMERGENCY PHONE DIALING TO DISCONNECTED PHONE#,REPAIR(11)PASSING GONG BUTTON DAMAGED,REPAIR(38)CAR TOP DIRTY CLEAN(85)NO 5YR TAG,PERFORM & FILE TEST(40)MACHINE ROOM KNOB & LOCKSETNothing owed — awaiting certificate of correction