← Back
BuildNYC
Elevator cooperative
161 EAST 91ST STREET
MANHATTAN · BIN 1048305
💬 Discuss this project
1941Year Built
6Stories
D4Building Class
R8BZoning
46,032 sfGross Floor Area
48Units
LL97 CoveredRent Stabilized0 Active ViolationsFISP: SAFE
Elevator cooperative · Owner of record: 161-165 E. 91st Street Owners · 10,067 sf lot · 4.57 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 6Unit 6FGH8p · 3 filings · 9 docs
Floor 5161 East 91st St Owners Coop2p · 1 filing · 3 docs
Floor 4Unit 4E, Unit 4F6p · 3 filings · 13 docs
Floor 3161 East 91st St Owners Coop2p · 1 filing · 3 docs
Floor 2Unit 2A, Unit 2H9p · 3 filings · 11 docs
Floor 1161 East 91st St Owners Coop2p · 1 filing · 3 docs
Site & exterior161 East 91st St Owners Coop9p · 3 filings · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
161-165 East 91st Street Owners2303/22/2026
Investment Private Wealth Advisor103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Mobile Office Architects, PC (Moa)206/28/2025
Eric Sheffield Architect210/14/2022
Melone Architects209/20/2022
Enthink Engineers108/30/2022
Porter Clapp Architects207/31/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Boyd Consulting403/21/2026
J.A.M. Associates403/21/2026
BMB Building Consulting203/21/2026
Tribeca Construction Consulting403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
I DimensionGeneral Contractor603/21/2026
Andamio ScaffoldingScaffold303/21/2026
Jepol ConstructionGeneral Contractor307/08/2026
Garadice BuildersGeneral Contractor203/21/2026
American Standard P&H CororpPlumbing107/08/2026
HI-Tech Plumbing & HeatingPlumbing107/08/2026
G-ElectricElectrical103/21/2026
J&M Plumbing of WestchesterPlumbing107/08/2026
Power Surge ElectricElectrical103/21/2026
Power Surge ElectricElectrical103/22/2026
Skyeline ConstructionGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Eric Sheffield Architect2195110/14/2022
Melone Architects2944109/20/2022
Building Lifecycle
All (92)Filed (9)Permit Issued (10)Signed Off (9)Facade (FISP) (12)Violation (28)Inspection (6)Objection (12)Special Inspection (6)
11/10/2025
Signed off — Alteration
REMOVAL OF MINOR INTERIOR PARTITION. PATCH AND REPAIR EXISTING FINISHES AT REMOVAL AREA. NO CHANGE OF USE, EGRESS OR BULK ARE PROPSED UNDER THIS APPLICATION.
M01245985-I1
08/13/2025
Permit issued — General Construction
M01245985-I1-GC
07/23/2025
Objection resolved — Addressed
07/12/2025
Objection resolved — Addressed
07/09/2025
Objection raised — Scope
07/09/2025
Objection raised — Cost
06/28/2025
Filed — Alteration
REMOVAL OF MINOR INTERIOR PARTITION. PATCH AND REPAIR EXISTING FINISHES AT REMOVAL AREA. NO CHANGE OF USE, EGRESS OR BULK ARE PROPSED UNDER THIS APPLICATION.
M01245985-I1
06/24/2025
Special inspection requirement — Final
Alan Ho
04/02/2025
Signed off — Alteration
INTERIOR RENOVATION OF COMBINATION OF APARTMENTS 6FGH AS PER PLANS.
M08020270-I1
04/01/2025
Signed off — Alteration
PLUMBING WORK ASSOCIATED WITH RENOVATION OF COMBINATION OF APTARTMENTS 6FGH AS PER PLANS.
M08016704-I1
03/31/2025
Permit issued — General Construction
M08020270-I1-MS
01/16/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/01/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/14/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/25/2024
Permit issued — Plumbing
M08016704-I1-PL
04/23/2024
Permit issued — Mechanical Systems
M08020270-I1-GC
12/01/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/17/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
M00797750-I1
04/13/2023
Signed off — Alteration
M07994490-I1
02/22/2023
Cycle 9 facade report signed — SAFE
02/15/2023
Cycle 9 facade inspection completed
12/01/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/18/2022
Signed off — Alteration
M00784551-I1
11/18/2022
Signed off — Alteration
Combine apartments 4E & 4F. Remove interior non-bearing partitions. New interior walls, doors, flooring, tiles.
M00784516-I1
11/07/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/04/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/26/2022
Objection raised — Fire_Protection
10/26/2022
Objection resolved — Addressed
10/25/2022
Objection raised — Scope
10/25/2022
Objection resolved — Addressed
10/25/2022
Objection raised — Scope
10/25/2022
Objection resolved — Addressed
10/24/2022
Permit issued — General Construction
M07994490-I1-GC
10/14/2022
Filed — Alteration
INTERIOR RENOVATION OF COMBINATION OF APARTMENTS 6FGH AS PER PLANS.
M08020270-I1
10/13/2022
Filed — Alteration
PLUMBING WORK ASSOCIATED WITH RENOVATION OF COMBINATION OF APTARTMENTS 6FGH AS PER PLANS.
M08016704-I1
09/30/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/22/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/20/2022
Filed — Alteration
M07994490-I1
08/30/2022
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. LIVE LOAD 300PSF.
M00797750-I1
08/30/2022
Permit issued — Sidewalk Shed
M00797750-I1-SH
08/29/2022
Permit issued — Plumbing
M00784551-I1-PL
08/26/2022
Special inspection requirement — Masonry
Nicholas Melone
08/26/2022
Special inspection requirement — Final
Nicholas Melone
08/24/2022
Permit issued — General Construction
M00784516-I1-GC
08/01/2022
Objection raised — Accessibility
08/01/2022
Objection resolved — Addressed
07/31/2022
Filed — Alteration
M00784551-I1
07/31/2022
Filed — Alteration
Combine apartments 4E & 4F. Remove interior non-bearing partitions. New interior walls, doors, flooring, tiles.
M00784516-I1
07/31/2022
Special inspection requirement — Final
P McClure Clapp
07/31/2022
Special inspection requirement — Lighting controls
P McClure Clapp
07/31/2022
Special inspection requirement — Lighting in dwelling units
P McClure Clapp
07/27/2022
Violation issued (ECB, closed)
Construction
07/18/2022
Cycle 9 facade report submitted
06/02/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/11/2022
Signed off — Alteration
Scope of work includes select brick masonry brick replacement and lintel maintenance as shown on drawings and as specified. No change in use, occupancy, or egress.
M00501716-I1
02/15/2022
Violation issued (HPD, closed)
A
08/27/2021
Permit issued — General Construction
M00501716-I1-GC
05/26/2021
Filed — Alteration
Scope of work includes select brick masonry brick replacement and lintel maintenance as shown on drawings and as specified. No change in use, occupancy, or egress.
M00501716-I1
05/18/2021
Signed off — Alteration
M00371372-I1
04/29/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Latest 60 of 92 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offSkyeline Construction08/13/2025
DOB NOWGeneral ConstructionSigned-offI Dimension03/31/2025
DOB NOWPlumbingSigned-offAmerican Standard P&H Cororp04/25/2024
DOB NOWMechanical SystemsSigned-offI Dimension04/23/2024
DOB NOWGeneral ConstructionSigned-offHudson Meridian Construction GP10/24/2022
DOB NOWSidewalk ShedSigned-offAndamio Scaffolding08/30/2022
DOB NOWPlumbingSigned-offJ&M Plumbing of Westchest08/29/2022
DOB NOWGeneral ConstructionSigned-offCR Safety Group08/24/2022
DOB NOWGeneral ConstructionSigned-offHudson Meridian Construction GP08/27/2021
DOB NOWPlumbingSigned-offHI-Tech Plumbing & Heating07/27/2020
BISMHISSUEDEuda Construction11/30/2020
BISOTISSUEDSkyeline Construction09/04/2020
BISOTISSUEDSkyeline Construction07/20/2020
BISOTISSUEDEuda Construction02/21/2020
BISMHISSUEDEuda Construction08/06/2019
BISBLISSUEDAbilene12/04/2017
BISBLISSUEDAbilene08/11/2017
BISPLISSUEDBell Fuel Oil06/21/2017
BISBLISSUEDAbilene06/21/2017
BISMHISSUEDEmg Industrial Chimney11/14/2016
BISPLISSUEDPlumbing & Heating Doctor12/17/2015
BISOTISSUEDFocus & Struga Building D11/25/2015
BISEQISSUEDRockledge Scaffold07/15/2014
BISPLISSUEDA. Heating and Plumbing Works03/18/2014
BISOTISSUEDArza Contracting03/14/2014
BISPLISSUEDSteve Belsito Sons05/21/2009
BISOTISSUEDCLN Home Improvement04/14/2009
BISPLISSUEDPyrosvestic Mechanical09/26/2007
BISPLISSUEDPyrosvestic Mechanical03/26/2007
BISOTISSUEDJ.A.L. Interiors03/07/2007
BISPLISSUEDI.M.P. Plumbing & Heating02/28/2007
BISOTISSUEDJ.A.L. Interiors02/21/2007
BISEQISSUEDSpring Scaffolding03/25/2003
BISPLISSUEDGraham PLG Co10/16/1998
BISOTISSUEDBeech Associates08/24/1998
BISPLISSUEDSignore & Sons Plumbing03/11/1994
BIS—ISSUEDJ.O.S. Construction09/20/1993
6 projects · most recent 04/23/2024
General Wiring
FiledStatusContractorScope
04/23/2024CompleteG-ElectricGeneral Wiring
03/04/2024CompletePower Surge ElectricGeneral Wiring
08/23/2022CompleteBorowide Elect'l Contractors—
04/28/2022CompleteTitan Electrical & Elev Contracting—
07/30/2020Permit IssuedMac Elect'l ContractingGeneral Wiring
03/01/2020CompleteJ.G.C. Electric—
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
01/16/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/14/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/07/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/04/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/30/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/22/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
06/24/2025FinalAlan Hoprogress
08/26/2022MasonryNicholas Melonespecial
08/26/2022FinalNicholas Meloneprogress
07/31/2022FinalP McClure Clappprogress
07/31/2022Lighting controlsP McClure Clappenergy_progress
07/31/2022Lighting in dwelling unitsP McClure Clappenergy_progress
▾Documents — 196 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch8
09/03/2026M00501716-I1Request digital key ↗
09/02/2026M00784551-I1Request digital key ↗
09/01/2026M00797750-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Plumbing1
09/04/2026M00371372-I1Request digital key ↗
▸Applications & Permits33
▸BISPLAN / WORK APPROVAL APPLICATION18
11/17/2020123819886Open ↗
11/10/2020123819886Open ↗
10/26/2020123819886Open ↗
Showing 3 of 18 on file for this type
▸BISWORK PERMIT APPLICATION15
07/20/2020140921028Open ↗
08/08/2019123819886Open ↗
08/06/2019123819886Open ↗
Showing 3 of 15 on file for this type
▸Seals & Professional Certifications42
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION15
08/06/2019123819886Open ↗
06/26/2019123819886Open ↗
03/27/2018140650677Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/04/2026M00371372-I1Open ↗
09/02/2026M00784551-I1Open ↗
09/02/2026M00784516-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/27/2026M07994490-I1Open ↗
08/24/2026M01245985-I1Open ↗
08/24/2026M00784516-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
06/14/2017140650677Open ↗
11/14/2016140573966Open ↗
12/16/2015122555831Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
07/07/2020140921028Open ↗
06/14/2017140650677Open ↗
11/14/2016140573966Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
12/16/2015122555831Open ↗
07/22/2014122058888Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
06/14/2017140650677Open ↗
11/14/2016140573966Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/07/2020140921028Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026M07994490-I1Open ↗
▸Trade Schedules & Equipment13
▸BISSCHEDULE B - PLUMBING5
10/26/2020123819886Open ↗
10/21/2020123819886Open ↗
09/30/2020123819886Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT3
12/04/2017140650677Open ↗
11/21/2017140650677Open ↗
06/14/2017140650677Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
06/26/2019123819886Open ↗
12/16/2015122555831Open ↗
01/23/2014121661503Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
06/27/2014121661503Open ↗
08/05/2009110385271Open ↗
▸Safety & Tenant Protection4
▸BISTenant Protection Plan and Notes2
07/07/2020140921028Open ↗
06/26/2019123819886Open ↗
▸BISSTREET TREE CHECKLIST1
11/10/2008110385271Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026M00371372-I1Open ↗
▸Environmental & Asbestos17
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/04/2026M00371372-I1Open ↗
09/02/2026M00784551-I1Open ↗
08/23/2026M01245985-I1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)7
07/07/2020140921028Open ↗
06/26/2019123819886Open ↗
06/14/2017140650677Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
07/22/2014122058888Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
11/10/2008110385271Open ↗
▸Energy Compliance21
▸BISAS-BUILT ENERGY ANALYSIS5
05/24/2021140921028Open ↗
11/25/2020123819886Open ↗
03/27/2018140650677Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
06/26/2019123819886Open ↗
03/27/2018140650677Open ↗
03/03/2017140573966Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
05/24/2021140921028Open ↗
11/25/2020123819886Open ↗
07/07/2020140921028Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
07/07/2020140921028Open ↗
06/14/2017140650677Open ↗
▸BISTR8: Energy Code Progress Inspections2
03/21/2014121661503Open ↗
01/23/2014121661503Open ↗
▸BISLIGHTING IN DWELLING UNITS1
07/13/2020140921028Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
07/13/2020140921028Open ↗
▸BISLIGHTING CONTROLS1
07/13/2020140921028Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026M00784516-I1Open ↗
▸Inspections & Test Reports9
▸BISTECHNICAL REPORT: RESPONSIBILITY7
05/24/2021140921028Open ↗
05/24/2021140921028Open ↗
12/04/2020123819886Open ↗
Showing 3 of 7 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
07/14/2020140921028Open ↗
▸BISMECHANICAL SYSTEMS1
12/07/2020123819886Open ↗
▸Approvals, Objections & Sign-offs14
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST8
05/24/2021140921028Open ↗
12/07/2020123819886Open ↗
03/27/2018140650677Open ↗
Showing 3 of 8 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
01/23/2014121661503Open ↗
11/16/2012121435241Open ↗
11/10/2008110385271Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
08/05/2015122058888Open ↗
09/21/2009110385271Open ↗
▸BISFINAL1
07/13/2020140921028Open ↗
▸Cost, Insurance & Ownership15
▸BISCOST AFFIDAVIT14
11/25/2020123819886Open ↗
07/07/2020140921028Open ↗
06/26/2019123819886Open ↗
Showing 3 of 14 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
03/19/2014121661503Open ↗
▸Filing & Intake Forms18
▸BISEFILING COVER SHEET6
06/26/2019123819886Open ↗
12/16/2015122555831Open ↗
07/22/2014122058888Open ↗
Showing 3 of 6 on file for this type
▸BISADDITIONAL INFORMATION6
10/16/2020123819886Open ↗
07/07/2020140921028Open ↗
08/21/2019123819886Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET4
07/07/2020140921028Open ↗
06/14/2017140650677Open ↗
11/14/2016140573966Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM2
03/27/2018140650677Open ↗
11/21/2017140650677Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
06/14/2017140650677Open ↗