← Back
One story retail building
1618 WESTCHESTER AVENUE
BRONX · Soundview-Bruckner-Bronx River · BIN 2024005
💬 Discuss this project
1925Year Built
1Stories
K1Building Class
C4-2Zoning
20,420 sfGross Floor Area
10Units
0 Open Violations
One story retail building · Owner of record: 1600 WESTCHESTER AVENUE BX LLC · 20,300 sf lot · 1.01 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingFire ProtectionGeneral
Roof7p · 2 filings · 17 docs
Floor 120p · 4 filings · 20 docs
Cellar18p · 4 filings · 20 docs
Site & exterior1p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OMAR HOLDINGS8007/08/2026
NEW LIFE HOLDING CORP.703/22/2026
WALGREENS603/21/2026
ANDREW KATZ ENGINEERING103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FLORINELA MURESAN105/22/2025
DESIGN GROUP IN H&K LLC903/20/2024
ALLEN SHINFELD, P.E. PLLC109/28/2023
SOUTH PARK CONSULTING LLC208/22/2023
PAUL DENIS ASSOCIATES411/05/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DESIGN GROUP IN H K1803/21/2026
GRAND EXPEDITERS NYC203/21/2026
YOUN DESIGN CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YS NY CONSTRUCTION INCGeneral Contractor1203/21/2026
YOUNG CHOEElectrical503/21/2026
C JAMES PLBG & HTG INCPlumbing407/08/2026
C.R.U. MECHAN & HEAT INCPlumbing207/08/2026
LINARES, LUISElectrical103/21/2026
NEPTUNE SIGNS AWNINGSScaffold107/08/2026
C.R.U. MECHAN & HEATIN INFire Protection107/08/2026
COW BAY SPRINKLER CORPGeneral Contractor103/21/2026
OBAR SYSTEMS, INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MWB ENGINEERING7942105/22/2025
DESIGN GROUP IN H&K LLC1363803/20/2024
MANCINI DUFFY ARCHITECTUR2985208/22/2023
PAUL DENIS ASSOCIATES2472411/05/2020
Building Lifecycle
All (105)Filed (17)Permit Issued (13)Signed Off (8)Violation (28)Inspection (9)Special Inspection (30)
12/11/2025
Signed off — Alteration
X01220578-I1
06/03/2025
Permit issued — Mechanical Systems
X01220578-I1-MS
05/22/2025
Filed — Alteration
X01220578-I1
04/01/2024
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-I1
04/01/2024
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-S1
03/20/2024
Filed — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-P5
03/20/2024
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-S2
03/20/2024
Special inspection requirement — Energy Code Compliance Inspections
SUKHWAN KIM
03/20/2024
Special inspection requirement — Final
SUKHWAN KIM
03/20/2024
Special inspection requirement — Interior lighting power
SUKHWAN KIM
03/20/2024
Special inspection requirement — Lighting controls
SUKHWAN KIM
03/20/2024
Special inspection requirement — HVAC-R and service water heating equipment
SUKHWAN KIM
03/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUKHWAN KIM
03/20/2024
Special inspection requirement — Mechanical Systems
SUKHWAN KIM
03/08/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/01/2024
Special inspection requirement — Sprinkler Systems
SUKHWAN KIM
03/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUKHWAN KIM
02/28/2024
Filed — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-P7
02/26/2024
Special inspection requirement — Sprinkler Systems
SUKHWAN KIM
02/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUKHWAN KIM
02/14/2024
Violation issued (ECB, closed)
Construction
02/12/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/12/2024
Inspection — Certified Sprinkler - SP - Roughing
Certified
View inspection ↗
02/01/2024
Signed off — Alteration
INSTALL AN ILLIUMINATED ACCESSORY BUSINESS SIGN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00927702-I1
11/30/2023
Filed — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-P6
11/30/2023
Inspection — Pass-Final Sign Permit Inspection
Pass
View inspection ↗
11/29/2023
Special inspection requirement — Sprinkler Systems
SUKHWAN KIM
11/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUKHWAN KIM
11/24/2023
Signed off — Alteration
HEREWITH FILING TO SUPERSEDE AND WITHDRAW APPLICATION 220256158. NO CONSTRUCTION WORK IS PROPOSED. THERE IS NO CHANGE TO THE USE, EGRESS OR OCCUPANCY. SEE COMMENTS SECTION.
X00909799-I1
11/17/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUKHWAN KIM
11/17/2023
Special inspection requirement — Interior lighting power
SUKHWAN KIM
11/17/2023
Special inspection requirement — Lighting controls
SUKHWAN KIM
11/17/2023
Special inspection requirement — HVAC-R and service water heating equipment
SUKHWAN KIM
11/17/2023
Special inspection requirement — Final
SUKHWAN KIM
11/17/2023
Special inspection requirement — Energy Code Compliance Inspections
SUKHWAN KIM
11/17/2023
Special inspection requirement — Mechanical Systems
SUKHWAN KIM
11/13/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/08/2023
Permit issued — Sign
X00927702-I1-SG
11/06/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/24/2023
Filed — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-P3
10/20/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUKHWAN KIM
10/19/2023
Special inspection requirement — Sprinkler Systems
SUKHWAN KIM
10/05/2023
Filed — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-P2
10/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUKHWAN KIM
10/03/2023
Special inspection requirement — Sprinkler Systems
SUKHWAN KIM
09/28/2023
Filed — Alteration
INSTALL AN ILLIUMINATED ACCESSORY BUSINESS SIGN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00927702-I1
09/08/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/08/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/05/2023
Filed — Alteration
INSTALLATION OF CONSTRUCTION FENCE IN CONJUNCTION WITH DOB# X00880863-I1. NO CHANGE IN USE, EGRESS, AND OCCUPANCY UNDER THIS APPLICATION.
X00880863-P1
08/31/2023
Special inspection requirement — Sprinkler Systems
SUKHWAN KIM
08/31/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUKHWAN KIM
08/24/2023
Permit issued — General Construction
X00909799-I1-GC
08/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Mandara
08/24/2023
Special inspection requirement — Final
William Mandara
08/22/2023
Filed — Alteration
HEREWITH FILING TO SUPERSEDE AND WITHDRAW APPLICATION 220256158. NO CONSTRUCTION WORK IS PROPOSED. THERE IS NO CHANGE TO THE USE, EGRESS OR OCCUPANCY. SEE COMMENTS SECTION.
X00909799-P1
08/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Mandara
08/21/2023
Special inspection requirement — Final
William Mandara
08/14/2023
Filed — Alteration
HEREWITH FILING TO SUPERSEDE AND WITHDRAW APPLICATION 220256158. NO CONSTRUCTION WORK IS PROPOSED. THERE IS NO CHANGE TO THE USE, EGRESS OR OCCUPANCY. SEE COMMENTS SECTION.
X00909799-I1
07/24/2023
Permit issued — Mechanical Systems
X00880863-I1-GC-CX
Latest 60 of 105 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offOBAR SYSTEMS, INC06/03/2025
DOB NOWSignSigned-offNEPTUNE SIGNS&AWNINGS INC11/08/2023
DOB NOWGeneral ConstructionSigned-offCOW BAY SPRINKLER CORP08/24/2023
DOB NOWMechanical SystemsSigned-offYS NY CONSTRUCTION INC07/24/2023
DOB NOWConstruction FenceSigned-offYS NY CONSTRUCTION INC07/24/2023
DOB NOWSprinklersSigned-offC.R.U. MECHAN & HEATIN IN07/20/2023
DOB NOWSprinklersSigned-offC.R.U. MECHAN & HEAT INC07/20/2023
DOB NOWConstruction FenceSigned-offYS NY CONSTRUCTION INC06/15/2023
DOB NOWMechanical SystemsSigned-offYS NY CONSTRUCTION INC06/07/2023
DOB NOWPlumbingSigned-offC JAMES PLBG & HTG INC12/07/2020
DOB NOWPlumbingSigned-offC JAMES PLBG & HTG INC12/07/2020
DOB NOWPlumbingSigned-offC JAMES PLBG & HTG INC03/27/2020
DOB NOWPlumbingSigned-offC JAMES PLBG & HTG INC03/25/2020
BISEQISSUEDALPHA ZK TEKNO CONTRACTOR07/27/2017
BISOTISSUEDALPHA ZK TEKNO CONTRACTOR07/27/2017
BISPLISSUEDG. & S. PLUMBING & HTG CO07/27/2017
BISOTISSUEDEXPERTISE PAINTING CORP10/09/2015
BISPLISSUEDPEAK MECH SOLUTIONS INC12/12/2012
BISOTISSUEDCOW BAY SPRINKLER CORP12/08/2011
BISPLISSUEDMAXIMUM MECHANICAL CORP.12/08/2011
BISPLISSUEDMETROTECH MECHANICAL CORP05/27/2011
BISOTISSUEDMAUCERI SIGN SYSTEMS LLC05/03/2011
BISOTRE-ISSUEDARA CONSTRUCTION CORP01/20/2011
BISOTISSUEDARA CONSTRUCTION CORP01/20/2011
BISOTISSUEDARA CONSTRUCTION CORP01/20/2011
BISEQISSUEDARA CONSTRUCTION CORP09/29/2010
BISMHISSUEDARA CONSTRUCTION CORP09/29/2010
BISOTISSUEDARA CONSTRUCTION CORP09/29/2010
BISEQISSUEDARA CONSTRUCTION CORP04/12/2010
BISMHISSUEDARA CONSTRUCTION CORP04/12/2010
BISOTISSUEDARA CONSTRUCTION CORP04/12/2010
BISOTISSUEDNATIONAL MAINTENANCE INC02/18/2010
BISOTISSUEDNATIONAL MAINTENANCE INC02/18/2010
BISOTISSUEDNATIONAL MAINTENANCE INC02/18/2010
BIS—ISSUEDNATIONAL MAINTENANCE, INC12/30/2008
BIS—ISSUEDNATIONAL MAINTENANCE, INC12/30/2008
BIS—ISSUEDNATIONAL MAINTENANCE, INC12/30/2008
BISFPISSUEDMASTER FIRE SYSTEMS, INC11/28/2005
BISPLISSUEDBLATT PLUMBING INC10/11/2005
BISOTISSUEDPIERIA ENTERPRISED INC.07/21/2005
+ 11 more permits on file
3 projects · most recent 10/24/2023
General Wiring Lighting
FiledStatusContractorScope
10/24/2023Permit IssuedY.S ELECTRICGeneral Wiring, Lighting
09/06/2023CompleteJONG HYUN KIM—
06/26/2023Permit IssuedY.S ELECTRICGeneral Wiring, Lighting
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
03/08/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/12/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/12/2024Certified Sprinkler - SP - RoughingCertifiedView ↗
11/30/2023Pass-Final Sign Permit InspectionPassView ↗
11/13/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/06/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/20/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/08/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/08/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 46
DateRequirementInspectorRole
03/20/2024Energy Code Compliance InspectionsSUKHWAN KIMprogress
03/20/2024FinalSUKHWAN KIMprogress
03/20/2024Interior lighting powerSUKHWAN KIMenergy_progress
03/20/2024Lighting controlsSUKHWAN KIMenergy_progress
03/20/2024HVAC-R and service water heating equipmentSUKHWAN KIMenergy_progress
03/20/2024Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
03/20/2024Mechanical SystemsSUKHWAN KIMspecial
03/01/2024Sprinkler SystemsSUKHWAN KIMspecial
03/01/2024Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
02/26/2024Sprinkler SystemsSUKHWAN KIMspecial
02/26/2024Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
11/29/2023Sprinkler SystemsSUKHWAN KIMspecial
11/29/2023Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
11/17/2023Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
11/17/2023Interior lighting powerSUKHWAN KIMenergy_progress
11/17/2023Lighting controlsSUKHWAN KIMenergy_progress
11/17/2023HVAC-R and service water heating equipmentSUKHWAN KIMenergy_progress
11/17/2023FinalSUKHWAN KIMprogress
11/17/2023Energy Code Compliance InspectionsSUKHWAN KIMprogress
11/17/2023Mechanical SystemsSUKHWAN KIMspecial
10/19/2023Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
10/19/2023Sprinkler SystemsSUKHWAN KIMspecial
10/03/2023Fire-Resistant Penetrations and JointsSUKHWAN KIMspecial
10/03/2023Sprinkler SystemsSUKHWAN KIMspecial
08/31/2023Sprinkler SystemsSUKHWAN KIMspecial
Latest 25 of 46.
▾Documents — 351 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch13
08/22/2026X00909799-I1Request digital key ↗
08/22/2026X00909799-P1Request digital key ↗
08/22/2026X00880863-S1Request digital key ↗
Showing 3 of 13 on file for this type
▸DOB NOWPlans/Sketch - Plumbing4
08/26/2026X00324842-I1Request digital key ↗
08/25/2026X00324801-I1Request digital key ↗
08/15/2026X00324842-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits64
▸BISPLAN / WORK APPROVAL APPLICATION38
01/08/2024220145475Open ↗
12/15/2023220145475Open ↗
12/14/2023220145475Open ↗
Showing 3 of 38 on file for this type
▸BISWORK PERMIT APPLICATION26
07/28/2017220590769Open ↗
07/28/2017220590769Open ↗
10/14/2015220256158Open ↗
Showing 3 of 26 on file for this type
▸Seals & Professional Certifications113
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION39
11/17/2017220590769Open ↗
07/27/2017220590769Open ↗
04/28/2017220590769Open ↗
Showing 3 of 39 on file for this type
▸DOB NOWProgress Inspector Seal & Signature22
09/27/2026X00909799-P1Open ↗
09/02/2026X00324842-I1Open ↗
09/02/2026X00324842-I1Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/26/2026X00324842-P1Open ↗
08/26/2026X00324842-I1Open ↗
08/25/2026X00324801-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature14
09/27/2026X00909799-P1Open ↗
09/11/2026X00880863-S1Open ↗
09/02/2026X00324842-I1Open ↗
Showing 3 of 14 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST11
10/05/2015220256158Open ↗
07/24/2014220192645Open ↗
01/29/2013220145475Open ↗
Showing 3 of 11 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM9
01/29/2013220145475Open ↗
10/13/2011220145475Open ↗
02/19/2010220049089Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/05/2015220256158Open ↗
▸Trade Schedules & Equipment22
▸BISSCHEDULE B - PLUMBING7
01/29/2013220145475Open ↗
10/13/2011220145475Open ↗
09/19/2011220037537Open ↗
Showing 3 of 7 on file for this type
▸BISSELF-CERT PLUMBING NOTICE6
01/24/2012220037537Open ↗
01/24/2012220037537Open ↗
12/30/2011220037537Open ↗
Showing 3 of 6 on file for this type
▸BISEQUIPMENT USE PERMITS3
04/27/2012220037537Open ↗
04/27/2012220037537Open ↗
04/27/2012220037537Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION3
07/24/2014220192645Open ↗
10/13/2011220145475Open ↗
08/16/2010220037537Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
04/06/2017220590769Open ↗
07/24/2014220192645Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
04/27/2012220037537Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST3
04/06/2017220590769Open ↗
10/13/2011220145475Open ↗
09/02/2010220080720Open ↗
▸BISST-1 Street Tree Checklist1
01/29/2013220145475Open ↗
▸Environmental & Asbestos21
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/22/2026X00880863-S1Open ↗
08/22/2026X00880863-I1Open ↗
08/22/2026X00880863-P6Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'5
09/02/2010220080720Open ↗
Showing 1 of 5 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
04/06/2017220590769Open ↗
10/05/2015220256158Open ↗
09/26/2014220405247Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS6
11/17/2017220590769Open ↗
07/27/2017220590769Open ↗
04/06/2017220590769Open ↗
Showing 3 of 6 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS1
11/17/2017220590769Open ↗
▸BISTR8: Energy Code Progress Inspections1
01/29/2013220145475Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
06/13/2011220080720Open ↗
01/25/2011220080720Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
01/25/2011220080720Open ↗
▸Approvals, Objections & Sign-offs43
▸BISLETTERS - SUPPORTING DOCUMENTATION18
09/11/2023220405247Open ↗
09/11/2023220405247Open ↗
07/24/2014220192645Open ↗
Showing 3 of 18 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST13
11/17/2017220590769Open ↗
06/04/2012210081613Open ↗
06/01/2012210081640Open ↗
Showing 3 of 13 on file for this type
▸BISADMINISTRATIVE OBJECTIONS10
10/05/2015220256158Open ↗
10/13/2011220145475Open ↗
09/03/2010220080720Open ↗
Showing 3 of 10 on file for this type
▸BISSUPERSEDING LETTER1
12/13/2012220145475Open ↗
▸BISMaster Plumber Seal Temporary Approval Letter1
06/18/2010220037537Open ↗
▸Cost, Insurance & Ownership28
▸BISCOST AFFIDAVIT28
11/17/2017220590769Open ↗
04/06/2017220590769Open ↗
10/05/2015220256158Open ↗
Showing 3 of 28 on file for this type
▸Filing & Intake Forms21
▸BISEFILING COVER SHEET17
04/05/2017220590769Open ↗
10/05/2015220256158Open ↗
09/26/2014220405247Open ↗
Showing 3 of 17 on file for this type
▸BISADDITIONAL INFORMATION3
07/17/2023220405247Open ↗
03/30/2012220037537Open ↗
03/30/2012220037537Open ↗
▸BISBOROUGH INTAKE FORM1
11/17/2017220590769Open ↗
▸Other Documents7
▸BISSEPTIC - SUPPORTING DOCUMENTATION6
10/13/2011220145475Open ↗
10/13/2011220145475Open ↗
10/13/2011220145475Open ↗
Showing 3 of 6 on file for this type
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
11/16/2023220256158Open ↗