← Back
BuildNYC
Walk-up apt, over six families with stores
164 WEST 80TH STREET
MANHATTAN · BIN 1031797
💬 Discuss this project
1900Year Built
4Stories
C7Building Class
R8BZoning
29,825 sfGross Floor Area
49Units
LL97 CoveredRent Stabilized3 Active Violations 0 unresolved · 3 paperwork only ▸
Walk-up apt, over six families with stores · Owner of record: Amsterdam 80 Developco · 8,480 sf lot · 3.52 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Floor 1HeatwiseUnder Construction9p · 3 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Zachary Sapinsley Lewis, R.A408/31/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Richard Lewis Architect303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Delphi ConstructionGeneral Contractor409/17/2026
T.N.T. Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TSF Engineering1274108/31/2026
Zachary Sapinsley Lewis9531108/31/2026
Metrospec Sia6420201/30/2024
Building Lifecycle
All (20)Filed (4)Permit Issued (3)Signed Off (2)Inspection (3)Special Inspection (8)
09/16/2026
Permit issued — Mechanical Systems
M01451355-I1-MS
08/31/2026
Filed — Alteration
Replacement of existing HVAC Unit for ground floor commercial space. No change to use egress or occupancy under this application.
M01451355-I1
08/28/2026
Special inspection requirement — Tenant Protection Plan Compliance
Zachary Lewis
08/25/2026
Special inspection requirement — Final
Zachary Lewis
08/25/2026
Special inspection requirement — Mechanical Systems
Nicholas Tucci
08/08/2024
Signed off — Alteration
Interior renovation of existing commercial space as per plan. No change to use, egress or occupancy under this application.
M00960639-S1
08/06/2024
Signed off — Alteration
Interior renovation of existing commercial space as per plan. No change to use, egress or occupancy under this application.
M00960639-I1
03/26/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/09/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/09/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/06/2024
Permit issued — Plumbing
M00960639-S1-PL
01/30/2024
Filed — Alteration
Interior renovation of existing commercial space as per plan. No change to use, egress or occupancy under this application.
M00960639-S1
01/30/2024
Special inspection requirement — Tenant Protection Plan Compliance
Michael Risbergs
01/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michael Risbergs
12/12/2023
Permit issued — General Construction
M00960639-I1-GC
11/13/2023
Filed — Alteration
Interior renovation of existing commercial space as per plan. No change to use, egress or occupancy under this application.
M00960639-I1
11/09/2023
Special inspection requirement — Final
Zachary Lewis
11/09/2023
Special inspection requirement — Tenant Protection Plan Compliance
Michael Risbergs
11/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Michael Risbergs
11/01/2023
Filed — Alteration
M00955599-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedDelphi Construction09/16/2026
DOB NOWPlumbingSigned-offT.N.T. Plumbing & Heating02/06/2024
DOB NOWGeneral ConstructionSigned-offDelphi Construction12/12/2023
1 project · most recent 08/31/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/31/2026Permit IssuedDelphi ConstructionAir Conditioning Systems
Cooling
Tosot TOSOT Model # TWH12AT19D6D1 12,000 BTU · Split System ×2
2 projects · most recent 09/30/2026
General Wiring
FiledStatusContractorScope
09/30/2026Permit IssuedKet ElectricGeneral Wiring
03/30/2024CompleteGreen Apple Electrical ServicesGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/26/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/09/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/09/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
08/28/2026Tenant Protection Plan ComplianceZachary Lewisspecial
08/25/2026FinalZachary Lewisprogress
08/25/2026Mechanical SystemsNicholas Tuccispecial
01/30/2024Tenant Protection Plan ComplianceMichael Risbergsspecial
01/29/2024Fire-Resistant Penetrations and JointsMichael Risbergsspecial
11/09/2023FinalZachary Lewisprogress
11/09/2023Tenant Protection Plan ComplianceMichael Risbergsspecial
11/09/2023Fire-Resistant Penetrations and JointsMichael Risbergsspecial
▾Tenants in the building
TenantSpaceFloorsRenovation projects
HeatwiseFitness / RecreationFloor 1
Project M01451355 Alteration · Permit Entire · 08/31/2026
Project M00960639 Alteration · LOC Issued · 11/13/2023
Project M00955599 Alteration · Approved · 11/01/2023
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
10/13/2026M01451355-I1Request digital key ↗
08/28/2026M00955599-I1Request digital key ↗
08/28/2026M00960639-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit4
09/18/2026M01451355-I1Open ↗
08/13/2026M00960639-S1Open ↗
08/13/2026M00960639-I1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/18/2026M01451355-I1Open ↗
08/28/2026M00955599-I1Open ↗
08/13/2026M00960639-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026M00960639-S1Open ↗
08/25/2026M00960639-I1Open ↗
08/25/2026M00960639-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/25/2026M00960639-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/18/2026M01451355-I1Open ↗
08/28/2026M00955599-I1Open ↗
08/13/2026M00960639-S1Open ↗
Showing 3 of 4 on file for this type
▸Other Documents2
▸DOB NOWProof of Historic Building2
08/13/2026M00955599-I1Open ↗
08/13/2026M00960639-I1Open ↗