DOB03/04/2020V-DOB VIOLATION - ACTIVE
ECB04/07/2026ELECTRICAL CLOSET NOT DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT ONLY. OBSERVED ON THE 1ST FL ELECTRICAL CLOSET WAS NOT DEDICATED TO ELECTRICAL FOUND COMPUTER SERVERS AND CAMERA RECORDING EQUIPMENT IN THE SNothing owed — awaiting certificate of correction
ECB04/07/2026ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED IN EXP #2 IN THE ALLEY THAT THE INSTALLATION OF A/C SPLIT UNIT COMPRESSOR, AND ONE NEW ELECTRICAL PANEL IN CAFETERIA TO POWER UNIT. FOUND NO PERMIT ON FILE IN BIZ/ DOBNothing owed — awaiting certificate of correction
ECB04/07/2026IN BASEMENT USING PVC PIPING ON WASTE LINE UNDER SLOPE SINK. IN CAFETERIA ROOM OPEN WASTE LINE. DOOR BY THE WATER METER STRIKES WASTE LINE PIPE. IN BASEMENT JIM CAPS ARE USED ON WASTE LINES. ALSO PIPE PENETRATINothing owed — awaiting certificate of correction
ECB04/07/2026OBSERVED THROUGHOUT THE BUILDING NO TRAP WRAP INSULATION UNDER SINKS IN BATHROOMS. ON 4TH FLOOR IN BATHROOM SPRINKLER HEAD NOT INSTALLED PROPERLY. THID FLOOR BATHROOM VENT IS BACK PITCHED. ON SECOND FLOOR BATHRNothing owed — awaiting certificate of correction
ECB04/07/2026CLASS 2: FIREFIGHTER'S SERVICE PHASE I SWITCH MULFUNCTIONING - CYLINDER ROTATES 360, NOT ALWAYS ACTIVATING PHASE I OPERATION MODE, REPAIR. TOE GUARD LOOSE, SECURE. PROVIDE UPDATED MAINTENANCE LOG (LAST RECORDSNothing owed — awaiting certificate of correction
ECB08/25/2025CLASS 2: FIRE TABS ON HOISTWAY DOORS HANGING ROLLERS ARE NOT SET TO THE UPRIGHT POSITION, RE-ADJUST. TOE GUARD LOOSE, SECURE. BOTH HOISTWAY AND CAR DOORS ARE NOT SETTTING TO FULLY OPEN POSITION, ADJUST. CAR DOONothing owed — awaiting certificate of correction
ECB10/18/2024DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, CALL THE D.O.B. ELEVATOR DIVISION AT (212) 393-2144 FOR A REINSPECTION. CLASS 2 ITEMS:BRAKENothing owed — awaiting certificate of correction