← Back
YWCA, YMCA, YWHA, YMHA, PAL
Madison Square Boys & Girls Club
1665 HOE AVENUE · Name © OpenStreetMap contributors · BIN 2010612
💬 Discuss this project
1971Year Built
3Stories
P3Building Class
R7-1Zoning
36,900 sfGross Floor Area
1Units
LL97 Covered0 Open Violations
YWCA, YMCA, YWHA, YMHA, PAL · Owner of record: COMMONPOINT NY, INC. D/B/A SAMUEL FIELD YM & YWHA · 20,000 sf lot · 1.85 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Roof1p · 1 filing · 5 docs
Floor 22p · 2 filings · 7 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
COMMONPOINT NY, INC. D/B/A SAMUEL FIELD YM & YWHA103/22/2026
PHOENIX 132 SUTTON ST INC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/27/2024$7.9M—MADISON SQUARE BOYS CLUB, INC. → COMMONPOINT NY, INC. D/B/A SAMUEL FIELD YM & YWHA$214/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VINCENT J. LIOTTA P.E.103/20/2024
JVA CONSULTING ENGINEERS104/21/2022
ROSENTHAL ENGINEERING PLLC109/01/2021
ESKW/ARCHITECTS108/06/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METROPOLIS GROUP INC203/21/2026
CASO ASSOCIATES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ANTENUCCI MECHANICAL INCPlumbing203/22/2026
ARCHER PLUMBING HEATINGPlumbing203/22/2026
CARMINE LIPPOLISElectrical103/21/2026
PINNACLE ENVIRONMENTAL COElectrical103/21/2026
AGEE HEATING SERVICE CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
VINCENT J. LIOTTA P. E.1974103/20/2024
PSI AGENCY INC.254104/21/2022
Building Lifecycle
All (35)Filed (4)Permit Issued (1)Signed Off (1)Violation (27)Special Inspection (2)
05/28/2025
Signed off — Alteration
INSTALLATION OF 2 CONDENSING UNITS ON THE ROOFTOP WITH A TOTAL CAPACITY OF 40 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
X01021699-I1
02/05/2025
Permit issued — Mechanical Systems
X01021699-I1-MS
03/20/2024
Filed — Alteration
INSTALLATION OF 2 CONDENSING UNITS ON THE ROOFTOP WITH A TOTAL CAPACITY OF 40 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
X01021699-I1
03/18/2024
Special inspection requirement — Mechanical Systems
Vincent Liotta
03/18/2024
Special inspection requirement — Final
Vincent Liotta
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/21/2022
Filed — Alteration
X00638567-I1
12/01/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/01/2021
Filed — Alteration
X00555468-I1
08/06/2021
Filed — Alteration
X00555466-I1
06/02/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/29/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/02/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/03/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/16/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/01/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/06/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/03/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/03/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/09/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offAGEE HEATING SERVICE02/05/2025
BISMHISSUEDSERVICE MECHANICAL INC07/28/2015
BISOTISSUEDJENNINGS CO., INC06/12/2015
BISOTISSUEDARCH BUILDERS, INC08/30/2007
BISEQISSUEDPHOENIX 132 SUTTON STREET INC07/26/2007
BISOTISSUEDC C CONTROLLED COMBUSTION03/13/2006
BISPLISSUEDG.BASSOLINO PLUMBING LTD03/13/2006
BISOTISSUEDELA AIR CONDITIONING09/15/1998
BISOTISSUEDADVATEX ASSOCIATES03/25/1992
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
03/18/2024Mechanical SystemsVincent Liottaspecial
03/18/2024FinalVincent Liottaprogress
▾Documents — 50 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026X00555466-I1Request digital key ↗
08/25/2026X00555468-I1Request digital key ↗
08/24/2026X00638567-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
01/15/2016220248373Open ↗
02/04/2015220248373Open ↗
02/07/2013220248373Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
07/30/2015220248373Open ↗
06/15/2015220248373Open ↗
08/30/2007210009328Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
06/06/2016220248373Open ↗
06/06/2016220248373Open ↗
05/13/2016220248373Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026X00555466-I1Open ↗
08/25/2026X00555468-I1Open ↗
08/21/2026X01021699-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: STATEMENT OF RESPONSIBILITY1
08/08/2007210009328Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026X01021699-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026X01021699-I1Open ↗
▸Trade Schedules & Equipment2
▸BISEQUIPMENT USE APPLICATION/PERMIT1
10/07/2016220248373Open ↗
▸BISEQUIPMENT USE PERMITS1
10/07/2016220248373Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
02/07/2013220248373Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
08/08/2007210009328Open ↗
07/17/2007210005171Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/07/2013220248373Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026X00638567-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00555466-I1Open ↗
▸Approvals, Objections & Sign-offs9
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
12/23/2024210005171Open ↗
07/07/2016220248373Open ↗
11/20/2007210009328Open ↗
▸BISADMINISTRATIVE OBJECTIONS3
02/07/2013220248373Open ↗
08/08/2007210009328Open ↗
07/17/2007210005171Open ↗
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter3
08/25/2026X00555466-I1Open ↗
08/13/2026X00555468-I1Open ↗
08/13/2026X01021699-I1Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
07/07/2016220248373Open ↗
02/07/2013220248373Open ↗
08/30/2007210009328Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
02/09/2016220248373Open ↗
01/15/2016220248373Open ↗
▸BISEFILING COVER SHEET1
02/07/2013220248373Open ↗