Floor 1Cellar excavation for additional height1 filing · 8 docs
CellarCellar excavation for additional height4p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Gykem Realty503/22/2026
1717 Linden Acquisition103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/26/2024$1.1M—ADORA LINDEN LLC → 1717 LINDEN ACQUISITION LLC$216/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Mohammad Ahead, PE204/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Ezfilingnycorp203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Mayer ImprovementsGeneral Contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Norman C. Lok818204/30/2025
Building Lifecycle
05/07/2026
(a) § hmc:file annual bedbug report in accordance with HPD rule as described on the back of this notice of violation or as described on HPDs…
HPD violation · closed
04/30/2026
Boiler inspection report filed
Initial · no defects · Accepted
06/26/2025
Boiler inspection report filed
Initial · no defects · Accepted
06/25/2025
Signed off — Alteration
EXCAVATE 3'-8" DEEP IN EXISTING CELLAR AREA TO ALLOW FOR ADDITIONAL HEIGHT IN CELLAR. EXISTING FOUNDATION WALLS TO REMAIN UN-ALTERED. FILING FOR THE INSTALLATION OF COLUMNS AND FOOTINGS AT THE CELLAR LEVEL. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01099742-S2
06/25/2025
Signed off — Alteration
EXCAVATE 3'-8" DEEP IN EXISTING CELLAR AREA TO ALLOW FOR ADDITIONAL HEIGHT IN CELLAR. EXISTING FOUNDATION WALLS TO REMAIN UN-ALTERED. FILING FOR THE INSTALLATION OF COLUMNS AND FOOTINGS AT THE CELLAR LEVEL. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01099742-I1
84 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offMayer Improvements06/06/2025
DOB NOWGeneral ConstructionSigned-offMayer Improvements03/07/2025
1 project · most recent 06/08/2025
General Wiring
FiledStatusContractorScope
06/08/2025Permit IssuedAccurate ElectricalGeneral Wiring
1 project · most recent 04/30/2025
Steel
FiledStatusContractorScope
04/30/2025Signed-offMayer ImprovementsSteel
1 project · most recent 04/30/2025
Fence
FiledStatusContractorScope
04/30/2025Signed-offMayer ImprovementsFence
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
12/10/2024Structural Stability – Alterations of existing buildingsNORMAN LOKspecial
08/21/2024Tenant Protection Plan ComplianceNORMAN LOKspecial
08/21/2024Excavations - Sheeting, Shoring, and BracingNORMAN LOKspecial
08/21/2024FinalADITYA DESAIprogress