← Back
Two stories - detached, small or mid-size
1757 EAST 26 STREET
BROOKLYN · Madison · BIN 3183501
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R3-2Zoning
1,364 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 3,000 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Attic12p · 3 filings · 10 docs
Floor 212p · 3 filings · 10 docs
Floor 113p · 3 filings · 10 docs
Cellar12p · 3 filings · 10 docs
Basement1p · 1 filing · 3 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/04/2020$940K—— → —$689/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JACK GREEN ASSOCIATES210/06/2021
KEVIN LOUIS PELLON108/19/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUPPORT BUILDINGS OF NEW YORK303/21/2026
SUPPORT BUILDINGS303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RICHY INCGeneral Contractor207/08/2026
GREGG NY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JACK GREEN ASSOCIATES422110/06/2021
Building Lifecycle
All (14)Filed (3)Permit Issued (3)Violation (3)Objection (4)Special Inspection (1)
12/01/2021
Permit issued — General Construction
B00571655-I1-GC
11/29/2021
Permit issued — Mechanical Systems
B00571710-I1-MS
11/10/2021
Permit issued — Plumbing
B00571724-I1-PL
10/06/2021
Filed — Alteration
B00571724-I1
10/06/2021
Filed — Alteration
Installation of the new duct work entire house, New AC unit on the attic and 1st floor, OSP. 2nd floor. Cellar
B00571710-I1
08/23/2021
Objection raised — Other
08/23/2021
Objection resolved — Addressed
08/23/2021
Objection raised — Other
08/23/2021
Objection resolved — Addressed
08/19/2021
Filed — Alteration
B00571655-I1
08/11/2021
Special inspection requirement — Final
KEVIN PELLON
07/21/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/29/2021
Violation issued (ECB, closed)
Construction
04/29/2021
Violation issued (ECB, closed)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedRICHY INC12/01/2021
DOB NOWMechanical SystemsPermit IssuedRICHY INC11/29/2021
DOB NOWPlumbingPermit IssuedGREGG NY PLUMBING, INC11/10/2021
1 project · most recent 10/06/2021
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
10/06/2021Permit IssuedRICHY INCAir Conditioning Systems, Heating Systems
Cooling
Johnson Controls TF3B3621S 36,000 BTU · Condensing Unit ×1
TF3B4821S 48,000 BTU · Condensing Unit ×1
Heating
Coleman TM8E080B12MP11A 36,000 BTU · Furnace ×1
TM9Y100C16MP11A 48,000 BTU · Furnace ×1
1 project · most recent 08/02/2021
General Wiring
FiledStatusContractorScope
08/02/2021Permit IssuedKINGS ELECTRIC CO., INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
08/11/2021FinalKEVIN PELLONprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
09/01/2026B00571710-I1Request digital key ↗
09/01/2026B00571724-I1Request digital key ↗
08/14/2026B00571655-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/01/2026B00571655-I1Open ↗
09/01/2026B00571710-I1Open ↗
09/01/2026B00571724-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026B00571655-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/01/2026B00571710-I1Open ↗
09/01/2026B00571724-I1Open ↗
08/14/2026B00571655-I1Open ↗