DOB11/09/2021V-DOB VIOLATION - ACTIVE
DOB11/09/2021V-DOB VIOLATION - ACTIVE
DOB10/22/2020V-DOB VIOLATION - ACTIVE
DOB10/30/2019V-DOB VIOLATION - ACTIVE
DOB09/06/2019VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
DOB11/16/2018V-DOB VIOLATION - ACTIVE
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB01/13/1997V-DOB VIOLATION - ACTIVE
ECB06/02/2026REISSUE ON ECB#35725411K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY ILLUMINATED DISCHARGE EXIT DOORS ANothing owed — awaiting certificate of correction
ECB06/02/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATEDCLASSROOM AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINDING,MISSING AND OR FAULTY HARDWARE ON CLASSROOMS 419,415,302,311,217,214,206,204,204B,Nothing owed — awaiting certificate of correction
ECB06/02/2026REISSUE ON ECB#35725407H EXIT DOOR NOT SELF-CLOSING.NOTED:EMERGENCY EXTERIOR EXIT DOOR NOT SELF-CLOSING DUE TO BINDING,MISSING AND OR FAULTYHARDWARE ON EMERGENCY EXTERIOR EXIT DOOR ON EXIT#8 1ST FLOOR MAIN ENTRNothing owed — awaiting certificate of correction
ECB06/02/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:BROKEN/CRACKED GLASS ON FIRE RATED SMOKE CLASSROOM B24 BASEMENT LEVEL AT BAND ROOM OBSERVED UPON INSPECTION.REM:REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB10/23/2025REISSUE #35671455Y DATE OF ISSUE: 08-24-2023. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED AT EXTERIOR PLAY YARD OUTSIDE OF GYMNASIUM ASPHALT PAVEMENT IS BUILDING, UNEVEN AND WITH CRACKS, POSINGNothing owed — awaiting certificate of correction
ECB10/23/2025REISSUE: 35677543Z DATE OF ISSUE: 07-09-2024. EXIT DOOR NOT SELF-CLOSING PROPERLY AT THE TIME OF INSPECTION. OBSERVED AND NOTED 2ND FL. STAIRWAY B 2 EXIT DOOR, 2ND FL. STAIRWAY "H" ONE EXIT DOOR, 1ST FLOOR EXITNothing owed — awaiting certificate of correction
ECB10/23/2025REISSUE #356775444K DATE OF ISSUE: 07-09-2024. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED ANDNOTED CAFETERIA KITCHEN EXIT PASSAGE WATER PENETRATION INTO AREA CONCRNothing owed — awaiting certificate of correction
ECB10/23/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. AT THE TIME OF INSPECTION OBSERVED AND NOTED AT 1ST FLOOR AUDITORIUM 4Nothing owed — awaiting certificate of correction
ECB08/30/2024PORTABLE STAGE LIFT WAS INSTALLED ILLEGALLY. NO DEVICE NUMBER ATTACHED TO IT DEVICE IS ILLEGAL., MAINTAIN ELEVATOR/CONVEYING SYSTEM; REMOVEDNothing owed — awaiting certificate of correction
ECB07/09/2024REISSUE 35676454M. FAILURE TO MAINTAIN IN CODE-COMPLIANT MANNER. CAFETERIA KITCHENETTE EXIT PASSAGE WATER PENETRATION INTO AREA CONCRETE OUTSIDE DOOR UNDER WALKWAY TO STAIR CRACKED AND FALLING APART SHOWING REBNothing owed — awaiting certificate of correction
ECB07/09/2024REISSUE 35676452Z. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. DOORS AND DOOR FRAME RUSTED DON'T OPEN ON EXIT 8 AND 2/3 AND EXIT 12. REMEDY: REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB08/24/2023REISSUE #35657627H. FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT CAFETERIA KITCHEN, FOUR BURNER GAS STOVE THAT DOES NOT HAVE ANSUL SYSTEM IN PLACE. REMEDY: REPAIR/REPLACE.Nothing owed — awaiting certificate of correction
ECB08/24/2023FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: NOTED AT EXTERIOR PLAY YARD OUTSIDE OF GYMNASIUM. ASPHALT PAVEMENT IS BULDGING, UNEVEN AND WITH CRACKS, POSING A TRIPPING HAZARD. REMEDY: REPAIR AND/OR REPNothing owed — awaiting certificate of correction
ECB08/24/2023REISSUE #35657629C. EXIT DOOR NOT SELF-CLOSING. NOTED EXTERIOR EXIT DOORS NOT CLOSING OR OPENING PROPERLY. AT GYMNASIUM EXIT 8 NOT OPENING, EXIT 2/3 DOOR IS WARPED, EXIT 12 FROM CAFETERIA IS STUCK IN CLOSED POSNothing owed — awaiting certificate of correction
ECB08/24/2023FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED AT CAFETERIA KITCHEN EXIT PASSAGE, EVIDENCE AT WATER PENETRATION THROUGH EXTERIOR WALL WITH SPALLING OF PLASTER AND STAING OF INTERIOR WALLS. REMEDY:Nothing owed — awaiting certificate of correction
ECB07/18/2022EXIT DOOR NOT SELFCLOSING.NOTED:OBSERVED ON 1FL,EXIT8 1OF THE DOOR ISNT OPENING.REPAIR/REPLACE DOOR.Nothing owed — awaiting certificate of correction
ECB07/18/2022REISSUE35554012J.FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.NOTED:OBSERVED IN KITCHEN WHERE THERES 4BURNER STOVE THAT DOESNT HAVE ANSHL SYSTEM IN PLACE.REPAIR&REPLACE.Nothing owed — awaiting certificate of correction
ECB05/18/2021REISSUE 35487003K FAILURE TO MAINTAIN BUILDING IS CODE COMPLIANT MANNER KICTHEN AREA HAS 4 BARRER COMMERICIAL GAS STOVE THAT DOES NOT HAVE ANUAL SYSTEM INSTALLED REPAIR AND OR REPLACENothing owed — awaiting certificate of correction
ECB07/18/2019FAILURE TO MAINTAIN BLD.IN NCODE COMPLIANT MANNER.NOTED:AT CAFETERIA 4BURNER COMMERCIAL GAS STOVE DOES NOT HAVE(ANSUL SYSTEM)REM:INSTALL A NSUL SYSTEM.Nothing owed — awaiting certificate of correction
ECB07/18/2019RE-ISSUE 335342196Z APPROVED PLACE OF ASSEMBLY PLANS NOT AVAILABLE FORINSPECTION.NOTED:NO PLANS AVAILABLE FOR BASEMENT CAFETERIA P/A#401884494 W/ROOM #B1J ERECTED DIVIDING CEILING LIGHTS W/PULL HEIGHT PARTITIONNothing owed — awaiting certificate of correction
ECB07/02/2018REISSUE #35147310J-APPROVED PLACE OF ASSEMBLY PLANS NOT AVAILABLE FOR INSPECTION: NO PLANS FOR BASEMENT CAFETERIA AVAILABLE.Nothing owed — awaiting certificate of correction
ECB07/25/2017RE ISSUE 35221887R APPROVED PLACE OF ASSEMBLY PLANS NOT AVAILABE. FOR INSPCETION.CAFETERIA PLANS NOT AVAILABLE.REM:PROVIDE APPROVED PLACE OF ASSEMBLY PLANS.Nothing owed — awaiting certificate of correction
ECB09/14/2015APPROVED PLACE OF ASSEMBLY PLANS NOT AVAILABLE FOR INSPECTION.NOTED NOPLANS AVAILABLE FOR BASEMENT CAFETERIA P/A#401884494 W/ ROOM#B1J INSTALLED DIVIDING CEILING LIGHTS.APPROX 20'LONG & 6'LONG FULL HEIGHT PARTINothing owed — awaiting certificate of correction