← Back
Two stories - detached, small or mid-size
189-26 46 AVENUE
QUEENS · BIN 4124871
💬 Discuss this project
1935Year Built
2.5Stories
A1Building Class
R4-1Zoning
1,980 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,900 sf lot · 0.68 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Floor 228p · 1 filing · 20 docs
Floor 128p · 1 filing · 20 docs
Cellar29p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/30/2021$910K—Private party → Private party$460/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LAM ENGINEER PC1004/11/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BROOKLYN AZ INCGeneral Contractor1503/21/2026
VILLAGE P & H NY INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LAM ENGINEER PC1180904/11/2023
SD TESTING & INSPECTION S7010211/09/2022
Building Lifecycle
All (92)Filed (10)Permit Issued (6)Signed Off (2)Violation (3)Inspection (7)Objection (34)Special Inspection (30)
04/13/2023
Special inspection requirement — Insulation placement and R values
YUK LAM
04/13/2023
Special inspection requirement — Concrete - Cast-In-Place
YUK LAM
04/13/2023
Special inspection requirement — Permanent certificate
YUK LAM
04/13/2023
Special inspection requirement — HVAC-R and service water heating system controls
YUK LAM
04/13/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
YUK LAM
04/13/2023
Special inspection requirement — Subgrade Inspections
YUK LAM
04/13/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
YUK LAM
04/13/2023
Special inspection requirement — Fenestration areas
YUK LAM
04/13/2023
Special inspection requirement — Interior lighting power
YUK LAM
04/13/2023
Special inspection requirement — Electric vehicle service equipment requirements
YUK LAM
04/13/2023
Special inspection requirement — Final
YUK LAM
04/13/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
YUK LAM
04/13/2023
Special inspection requirement — Masonry
YUK LAM
04/13/2023
Special inspection requirement — Structural Steel - Details
YUK LAM
04/13/2023
Special inspection requirement — Footing and Foundation
YUK LAM
04/13/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
YUK LAM
04/13/2023
Special inspection requirement — Fenestration air leakage
YUK LAM
04/13/2023
Special inspection requirement — Metering
YUK LAM
04/13/2023
Special inspection requirement — HVAC-R and service water heating equipment
YUK LAM
04/13/2023
Special inspection requirement — Air barrier - visual inspection
YUK LAM
04/13/2023
Special inspection requirement — Maintenance information
YUK LAM
04/13/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YUK LAM
04/11/2023
Filed — Alteration CO
Proposed partial demolition and 2 story brick horizontal enlargement of existing 2 story and attic brick dwelling as per plan submitted. Convert from one to two dwelling units. Obtain a new certificate of occupancy.
Q00634180-P7
03/29/2023
Filed — Alteration CO
Proposed partial demolition and 2 story brick horizontal enlargement of existing 2 story and attic brick dwelling as per plan submitted. Convert from one to two dwelling units. Obtain a new certificate of occupancy.
Q00634180-P6
03/29/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
YUK LAM
03/29/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
YUK LAM
03/29/2023
Special inspection requirement — Structural Steel - Details
YUK LAM
03/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YUK LAM
03/29/2023
Special inspection requirement — Concrete - Cast-In-Place
YUK LAM
03/29/2023
Special inspection requirement — Masonry
YUK LAM
03/29/2023
Special inspection requirement — Subgrade Inspections
YUK LAM
03/29/2023
Special inspection requirement — Final
YUK LAM
03/10/2023
Filed — Alteration CO
Proposed partial demolition and 2 story brick horizontal enlargement of existing 2 story and attic brick dwelling as per plan submitted. Convert from one to two dwelling units. Obtain a new certificate of occupancy.
Q00634180-P4
12/02/2022
Signed off — Alteration
PROPOSED PLUMBING WORK IN CONJUNCTION WITH JOB#Q00634180. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q00663491-I1
11/30/2022
Filed — Alteration CO
Proposed partial demolition and 2 story brick horizontal enlargement of existing 2 story and attic brick dwelling as per plan submitted. Convert from one to two dwelling units. Obtain a new certificate of occupancy.
Q00634180-P3
11/29/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/09/2022
Filed — Alteration
PROPOSED PLUMBING WORK IN CONJUNCTION WITH JOB#Q00634180. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q00663491-P1
11/09/2022
Filed — Alteration CO
Proposed partial demolition and 2 story brick horizontal enlargement of existing 2 story and attic brick dwelling as per plan submitted. Convert from one to two dwelling units. Obtain a new certificate of occupancy.
Q00634180-P2
11/09/2022
Signed off — Alteration
Q00663493-I1
11/01/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
08/10/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/08/2022
Filed — Alteration CO
Proposed partial demolition and 2 story brick horizontal enlargement of existing 2 story and attic brick dwelling as per plan submitted. Convert from one to two dwelling units. Obtain a new certificate of occupancy.
Q00634180-P1
07/05/2022
Violation issued (ECB, closed)
Construction
06/29/2022
Permit issued — Structural
Q00634180-I1-GC-CX
06/29/2022
Permit issued — General Construction
Q00634180-I1-GC-CX
05/23/2022
Violation issued (ECB, closed)
Construction
05/11/2022
Permit issued — Construction Fence
Q00663493-I1-FN
05/05/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/05/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/05/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/05/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/21/2022
Violation issued (ECB, closed)
Site Safety
03/15/2022
Permit issued — Plumbing
Q00663491-I1-PL
03/04/2022
Permit issued — Foundation
Q00634180-I1-GC-CX
03/02/2022
Permit issued — Construction Fence
Q00663493-I1-FN
02/15/2022
Objection raised — Admin
02/15/2022
Objection resolved — Addressed
02/15/2022
Objection raised — Admin
02/15/2022
Objection resolved — Addressed
02/15/2022
Objection raised — Inspections
Latest 60 of 92 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedBROOKLYN AZ INC06/29/2022
DOB NOWGeneral ConstructionPermit IssuedBROOKLYN AZ INC06/29/2022
DOB NOWConstruction FenceSigned-offBROOKLYN AZ INC05/11/2022
DOB NOWPlumbingSigned-offVILLAGE P & H NY INC03/15/2022
DOB NOWFoundationPermit IssuedBROOKLYN AZ INC03/04/2022
DOB NOWConstruction FenceSigned-offBROOKLYN AZ INC03/02/2022
1 project · most recent 03/23/2022
General Wiring
FiledStatusContractorScope
03/23/2022CompleteERIC & NG ELEC'L, INC.General Wiring
1 project · most recent 04/11/2023
Steel Masonry Wood
FiledStatusContractorScope
04/11/2023Permit IssuedBROOKLYN AZ INCSteel, Masonry, Wood
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
11/29/2022Pass-Final CND-Occupancy InspectionPassView ↗
11/01/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/10/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/05/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/05/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/05/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/05/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 128
DateRequirementInspectorRole
04/13/2023Insulation placement and R valuesYUK LAMenergy_progress
04/13/2023Fire-Resistant Penetrations and JointsYUK LAMspecial
04/13/2023Concrete - Cast-In-PlaceYUK LAMspecial
04/13/2023Subgrade InspectionsYUK LAMspecial
04/13/2023Structural Steel - DetailsYUK LAMspecial
04/13/2023MasonryYUK LAMspecial
04/13/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationYUK LAMspecial
04/13/2023Structural Stability – Alterations of existing buildingsYUK LAMspecial
04/13/2023FinalYUK LAMprogress
04/13/2023Footing and FoundationYUK LAMprogress
04/13/2023Fenestration and door U-factor and product ratingsYUK LAMenergy_progress
04/13/2023HVAC-R and service water piping design and insulationYUK LAMenergy_progress
04/13/2023Fenestration air leakageYUK LAMenergy_progress
04/13/2023MeteringYUK LAMenergy_progress
04/13/2023Fenestration areasYUK LAMenergy_progress
04/13/2023Permanent certificateYUK LAMenergy_progress
04/13/2023HVAC-R and service water heating equipmentYUK LAMenergy_progress
04/13/2023Air barrier - visual inspectionYUK LAMenergy_progress
04/13/2023Interior lighting powerYUK LAMenergy_progress
04/13/2023Maintenance informationYUK LAMenergy_progress
04/13/2023Electric vehicle service equipment requirementsYUK LAMenergy_progress
04/13/2023HVAC-R and service water heating system controlsYUK LAMenergy_progress
03/29/2023Interior lighting powerYUK LAMenergy_progress
03/29/2023HVAC-R and service water heating equipmentYUK LAMenergy_progress
03/29/2023Electric vehicle service equipment requirementsYUK LAMenergy_progress
Latest 25 of 128.
▾Documents — 119 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/26/2026Q00663491-P1Request digital key ↗
08/26/2026Q00663493-I1Request digital key ↗
08/25/2026Q00634180-P7Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records8
▸DOB NOWZD1: DOB Zoning Diagram7
08/15/2026Q00634180-I1Open ↗
08/13/2026Q00634180-P1Open ↗
08/13/2026Q00634180-P2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026Q00634180-I1Open ↗
▸Seals & Professional Certifications53
▸DOB NOWSpecial Inspector Seal & Signature24
09/02/2026Q00663491-I1Open ↗
09/02/2026Q00663491-I1Open ↗
09/01/2026Q00634180-P3Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWProgress Inspector Seal & Signature19
09/02/2026Q00663491-I1Open ↗
09/02/2026Q00663491-I1Open ↗
09/01/2026Q00634180-P3Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/25/2026Q00634180-P1Open ↗
08/25/2026Q00634180-P7Open ↗
08/25/2026Q00634180-P6Open ↗
Showing 3 of 10 on file for this type
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist7
08/25/2026Q00634180-P7Open ↗
08/25/2026Q00634180-P6Open ↗
08/25/2026Q00634180-P4Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/25/2026Q00634180-P2Open ↗
08/25/2026Q00634180-P7Open ↗
08/25/2026Q00634180-P6Open ↗
Showing 3 of 9 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/15/2026Q00634180-I1Open ↗
08/13/2026Q00663491-I1Open ↗
▸Other Documents30
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone7
08/15/2026Q00634180-I1Open ↗
08/13/2026Q00634180-P3Open ↗
08/13/2026Q00634180-P2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWPlot Diagram7
08/15/2026Q00634180-I1Open ↗
08/13/2026Q00634180-P3Open ↗
08/13/2026Q00634180-P4Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProperty Ownership Certification7
08/25/2026Q00634180-P1Open ↗
08/25/2026Q00634180-P7Open ↗
08/25/2026Q00634180-P6Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSite Survey: Initial7
08/15/2026Q00634180-I1Open ↗
08/13/2026Q00634180-P7Open ↗
08/13/2026Q00634180-P3Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWFinal Survey1
08/15/2026Q00634180-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/15/2026Q00634180-I1Open ↗