| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 04/05/2022 | $5.3M | — | — → — | $1,911/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| RJD ENGINEERING LLC | 2 | 06/03/2026 |
| GAMILL ENGINEERING, P.C | 5 | 07/29/2025 |
| BAXT INGUI ARCHITECTS | 8 | 04/11/2025 |
| GEO | 2 | 11/09/2023 |
| D'HUY ENGINEERING, INC. | 1 | 01/11/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| GAMILL ENGINEERING, PC | 34 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| TAFFERA FINE BUILDING AND | General Contractor | 35 | 07/08/2026 |
| DYNAMIC BLUE WATER MECH | Plumbing | 4 | 07/08/2026 |
| PACIFIC PLBG. & HTG. CORP | Fire Protection | 2 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| MACIA INSPECTION & TESTIN | 402 | 15 | 06/03/2026 |
| GAMILL ENGINEERING, P.C. | 1773 | 4 | 07/29/2025 |
| TRISTATE PLANNING ENGINEE | 8344 | 1 | 01/31/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Signed-off | PACIFIC PLBG. & HTG. CORP | 12/17/2025 |
| DOB NOW | Structural | Signed-off | TAFFERA FINE BUILDING AND | 12/16/2025 |
| DOB NOW | General Construction | Permit Issued | TAFFERA FINE BUILDING AND | 12/15/2025 |
| DOB NOW | Support of Excavation | Signed-off | TAFFERA FINE BUILDING AND | 11/18/2025 |
| DOB NOW | Mechanical Systems | Signed-off | TAFFERA FINE BUILDING AND | 11/18/2025 |
| DOB NOW | Plumbing | Signed-off | SUPER PLUMBERS CORP | 06/06/2025 |
| DOB NOW | Sprinklers | Signed-off | PACIFIC PLBG. & HTG. CORP | 12/09/2024 |
| DOB NOW | Foundation | Signed-off | TAFFERA FINE BUILDING AND | 11/21/2024 |
| DOB NOW | Mechanical Systems | Signed-off | TAFFERA FINE BUILDING AND | 11/18/2024 |
| DOB NOW | Support of Excavation | Signed-off | TAFFERA FINE BUILDING AND | 11/18/2024 |
| DOB NOW | Construction Fence | Signed-off | TAFFERA FINE BUILDING AND | 11/18/2024 |
| DOB NOW | Structural | Signed-off | TAFFERA FINE BUILDING AND | 10/22/2024 |
| DOB NOW | Plumbing | Signed-off | SUPER PLUMBERS CORP | 06/06/2024 |
| DOB NOW | General Construction | Permit Issued | TAFFERA FINE BUILDING AND | 11/14/2023 |
| DOB NOW | Mechanical Systems | Permit Issued | TAFFERA FINE BUILDING AND | 11/08/2023 |
| DOB NOW | Support of Excavation | Signed-off | TAFFERA FINE BUILDING AND | 11/08/2023 |
| DOB NOW | Construction Fence | Signed-off | TAFFERA FINE BUILDING AND | 11/06/2023 |
| DOB NOW | General Construction | Signed-off | TAFFERA FINE BUILDING AND | 10/26/2023 |
| DOB NOW | Construction Fence | Signed-off | TAFFERA FINE BUILDING AND | 10/19/2023 |
| DOB NOW | General Construction | Permit Issued | TAFFERA FINE BUILDING AND | 08/11/2023 |
| DOB NOW | Support of Excavation | Signed-off | TAFFERA FINE BUILDING AND | 07/13/2023 |
| DOB NOW | Plumbing | Signed-off | SUPER PLUMBERS CORP | 07/06/2023 |
| DOB NOW | Plumbing | Signed-off | SUPER PLUMBERS CORP | 06/27/2023 |
| DOB NOW | Mechanical Systems | Signed-off | TAFFERA FINE BUILDING AND | 06/21/2023 |
| DOB NOW | General Construction | Signed-off | TAFFERA FINE BUILDING AND | 02/17/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/03/2026 | Signed-off | TAFFERA FINE BUILDING AND | Air Conditioning Systems, Heating Systems | Cooling Mitsubishi Electric MXZ-SM42NAMHZ 42,000 BTU · Condensing Unit ×1 PEFY-P06NMAU-E4 6,000 BTU · Vrf Indoor ×1 PEFY-P08NMAU-E4 8,000 BTU · Vrf Indoor ×2 PEFY-P12NMSU-E 12,000 BTU · Vrf Indoor ×1 PVFY-P08NAMU-E1 8,000 BTU · Vrf Indoor ×2 PVFY-P12NAMU-E1 12,000 BTU · Vrf Indoor ×2 SEZ-KD09NA4 9,000 BTU · Fan Coil Indoor ×1 SUZ-KA09NAHZ 48,000 BTU · Condensing Unit ×1 MXZ-SM36NAMHZ-U1 42,000 BTU · Condensing Unit ×1 PEFY-P06NAMU-E4 6,000 BTU · Vrf Indoor ×1 PMFY-P06NBMU-E5 6,000 BTU · Vrf Indoor ×1 PMFY-P06NBMU-ER5 6,000 BTU · Vrf Indoor ×1 Heating Mitsubishi Electric MXZ-SM36NAMHZ-U1 48,000 BTU · Heat Pump Outdoor ×2 PEFY-P06NAMU-E4 6,700 BTU · Vrf Indoor ×2 PEFY-P08NMAU-E4 9,000 BTU · Vrf Indoor ×2 PEFY-P12NMSU-E 6,700 BTU · Vrf Indoor ×1 PVFY-P08NAMU-E1 9,000 BTU · Vrf Indoor ×2 PVFY-P12NAMU-E1 13,500 BTU · Vrf Indoor ×2 SEZ-KD09NA-4 12,500 BTU · Fan Coil Indoor ×1 PMFY-P06NAMU-R5 6,700 BTU · Vrf Indoor ×1 PMFY-P06NBMU-ER5 6,700 BTU · Vrf Indoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/29/2025 | Signed-off | PACIFIC PLBG. & HTG. CORP | 141 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/11/2025 | Signed-off | DYNAMIC BLUE WATER MECH | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/10/2025 | Complete | SUPER CHARGED ELEC. INC. | General Wiring |
| 06/28/2023 | Complete | SUPER CHARGED ELEC. INC. | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/31/2025 | Signed-off | TAFFERA FINE BUILDING AND | Steel, Concrete, Masonry, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/07/2026 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 08/03/2026 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 02/11/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 04/25/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 04/25/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 05/03/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 09/19/2022 | Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish | Certified | View ↗ |
| 09/19/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 09/14/2022 | Certified Sprinkler (PL)-Sprinkler-Hydro | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/21/2026 | Mechanical Systems | CHUNG CHING JEN | special |
| 06/21/2026 | Final | Nicholas Palumbo | progress |
| 06/21/2026 | Energy Code Compliance Inspections | CHUNG CHING JEN | progress |
| 06/21/2026 | Maintenance information | CHUNG CHING JEN | energy_progress |
| 06/21/2026 | HVAC-R and service water heating system controls | CHUNG CHING JEN | energy_progress |
| 06/21/2026 | HVAC-R and service water piping design and insulation | CHUNG CHING JEN | energy_progress |
| 06/21/2026 | HVAC-R and service water heating equipment | CHUNG CHING JEN | energy_progress |
| 06/21/2026 | Fire-Resistant Penetrations and Joints | CHUNG CHING JEN | special |
| 05/19/2026 | Fire-Resistant Penetrations and Joints | CHUNG CHING JEN | special |
| 05/19/2026 | HVAC-R and service water heating equipment | CHUNG CHING JEN | energy_progress |
| 05/19/2026 | Maintenance information | CHUNG CHING JEN | energy_progress |
| 05/19/2026 | HVAC-R and service water piping design and insulation | CHUNG CHING JEN | energy_progress |
| 05/19/2026 | HVAC-R and service water heating system controls | CHUNG CHING JEN | energy_progress |
| 05/19/2026 | Final | CHUNG CHING JEN | progress |
| 05/19/2026 | Energy Code Compliance Inspections | CHUNG CHING JEN | progress |
| 05/19/2026 | Mechanical Systems | CHUNG CHING JEN | special |
| 08/21/2025 | Sprinkler Systems | JACK GAMILL | special |
| 08/21/2025 | Fire-Resistant Penetrations and Joints | Nicholas Palumbo | special |
| 07/28/2025 | Sprinkler Systems | JACK GAMILL | special |
| 07/28/2025 | Fire-Resistant Penetrations and Joints | Jeffrey Stones | special |
| 04/23/2025 | Fire-Resistant Penetrations and Joints | CHUNG CHING JEN | special |
| 04/23/2025 | HVAC-R and service water piping design and insulation | Nicholas Palumbo | energy_progress |
| 04/23/2025 | Energy Code Compliance Inspections | CHUNG CHING JEN | progress |
| 04/09/2025 | HVAC-R and service water piping design and insulation | Jeffrey Stones | energy_progress |
| 04/09/2025 | Fire-Resistant Penetrations and Joints | Jeffrey Stones | special |