Roof17p · 6 filings · 20 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbing
Issued Permit Scope
Boiler Equipment · General Construction · Mechanical Systems · Plumbing · Sprinklers
Mechanical additions, modifications, and demolition as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
17 documents · 4 drawing sheets
INTERIOR FIT OUT ONLY as per plans filed herewith. No change to use, egress, or occupancy. ALT CO approved under DOB NOW application M00504199-I1.
On file for this project
6 documents · 7 drawing sheets
Plumbing/Sprinkler additions, modifications, and demolition as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
6 documents · 5 drawing sheets
Latest 3 of 6 filings on this floor.
Bulkhead1p · 1 filing · 4 docs
Architecture
Alt 2 Directive 2 for a temporary Use Permit Filing as per plans filed herewith.
On file for this project
4 documents · 1 drawing sheet
Floor 202p · 4 filings · 20 docs
ArchitectureFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Structural renovations including new elevator at 20th floor and new generator room with support framing from 17th to 20th floor as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
11 documents · 1 drawing sheet
Mechanical additions, modifications, and demolition as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
17 documents
INTERIOR FIT OUT ONLY as per plans filed herewith. No change to use, egress, or occupancy. ALT CO approved under DOB NOW application M00504199-I1.
On file for this project
6 documents · 1 drawing sheet
Latest 3 of 4 filings on this floor.
Floor 192p · 4 filings · 20 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Structural renovations including new elevator at 20th floor and new generator room with support framing from 17th to 20th floor as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
11 documents · 1 drawing sheet
Mechanical additions, modifications, and demolition as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
17 documents
INTERIOR FIT OUT ONLY as per plans filed herewith. No change to use, egress, or occupancy. ALT CO approved under DOB NOW application M00504199-I1.
On file for this project
6 documents · 1 drawing sheet
Latest 3 of 4 filings on this floor.
Floor 182p · 3 filings · 20 docs
ArchitectureDMGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Structural
Structural renovations including new elevator at 20th floor and new generator room with support framing from 17th to 20th floor as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
11 documents · 1 drawing sheet
Mechanical additions, modifications, and demolition as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
17 documents
INTERIOR FIT OUT ONLY as per plans filed herewith. No change to use, egress, or occupancy. ALT CO approved under DOB NOW application M00504199-I1.
On file for this project
6 documents · 1 drawing sheet
Floor 171p · 1 filing · 11 docs
GeneralMechanicalPlumbingStructural
Issued Permit Scope
Mechanical Systems · Plumbing · Structural
Structural renovations including new elevator at 20th floor and new generator room with support framing from 17th to 20th floor as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
11 documents · 1 drawing sheet
Floor 162p · 3 filings · 8 docs
ArchitectureFire ProtectionMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Mechanical modifications and demolition as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
15 documents
Interior renovations and modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
18 documents · 2 drawing sheets
Plumbing modifications and demolition, and sprinkler modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
18 documents
Floor 153 filings · 8 docs
ArchitectureFire ProtectionMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Mechanical modifications and demolition as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
15 documents
Interior renovations and modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
18 documents
Plumbing modifications and demolition, and sprinkler modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
18 documents
Floor 14
Floor 13
Floor 12
Floor 11
Floor 10
Floor 9
Floor 8
Floor 7
Floor 6
Floor 5
Floor 4
Floor 3
Floor 218p · 5 filings · 20 docs
ArchitectureElectricalFire AlarmFire ProtectionGeneralMechanicalPlumbing
Issued Permit Scope
Mechanical Systems · Plumbing · Sprinklers
Plumbing modifications and demolition, and sprinkler modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
45 documents · 1 drawing sheet
Modifications to existing plumbing/sprinkler fixtures as per plans filled herewith.
On file for this project
24 documents · 5 drawing sheets
Modifications to existing mechanical systems as per plans filled herewith. No change in use, egress or occupancy.
On file for this project
6 documents · 12 drawing sheets
Latest 3 of 5 filings on this floor.
Floor 110p · 6 filings · 20 docs
ArchitectureFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Plumbing modifications and demolition, and sprinkler modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
45 documents · 3 drawing sheets
Structural modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
10 documents · 1 drawing sheet
Filed herewith to change use & occupancy on the rooftop and for change on egress on floors 19 & 20 as per plans filed herewith.
On file for this project
47 documents · 4 drawing sheets
Latest 3 of 6 filings on this floor.
Mezzanine15p · 5 filings · 20 docs
ArchitectureElectricalFire AlarmFire ProtectionGeneralMechanicalPlumbingOther
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Modifications to existing plumbing/sprinkler fixtures as per plans filled herewith.
On file for this project
24 documents · 7 drawing sheets
Filed herewith to change use & occupancy on the rooftop and for change on egress on floors 19 & 20 as per plans filed herewith.
On file for this project
47 documents · 4 drawing sheets
Modifications to existing mechanical systems as per plans filled herewith. No change in use, egress or occupancy.
On file for this project
6 documents · 10 drawing sheets
Latest 3 of 5 filings on this floor.
Cellar18p · 4 filings · 20 docs
ArchitectureFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Plumbing modifications and demolition, and sprinkler modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
45 documents · 9 drawing sheets
Structural modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
10 documents · 1 drawing sheet
Filed herewith to change use & occupancy on the rooftop and for change on egress on floors 19 & 20 as per plans filed herewith.
On file for this project
47 documents · 6 drawing sheets
Latest 3 of 4 filings on this floor.
Sub-Cellar6p · 3 filings · 20 docs
ArchitectureFire ProtectionGeneralMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Plumbing modifications and demolition, and sprinkler modifications as per plans filed herewith. No change to use, egress, or occupancy.
On file for this project
45 documents · 3 drawing sheets
Filed herewith to change use & occupancy on the rooftop and for change on egress on floors 19 & 20 as per plans filed herewith.
On file for this project
47 documents · 1 drawing sheet
Mechanical modifications including hood and duct work in the cellar and 1st floor existing kitchens working with commercial cooking equipment as per previously approved plans. No change to use, egress, or occupancy.
On file for this project
24 documents · 2 drawing sheets
Site & exterior4 filings · 12 docs
ArchitectureCivilEquipmentGeneralMechanicalPlumbingStructural
Issued Permit Scope
Construction Fence · Sidewalk Shed · Supported Scaffold
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
On file for this project
2 documents · 5 drawing sheets
INSTALLATION OF 300 psf SIDEWALK SHED AS PER PLANS. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2014 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this project
4 documents · 8 drawing sheets
INSTALLATION OF PIPE SCAFFOLDING, NEEDLE BEAMS AND ROOF PROTECTION AS PER PLANS. TEMPORARY EQUIPMENT SHALL COMPLY WITH CHAPTER # 33 OF THE 2022 CODE, NO CHANGESS IN USE IN EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this project
4 documents · 9 drawing sheets
Latest 3 of 4 filings on this floor.
Filed — no permit issued3 filings · 14 docs
ArchitectureFire ProtectionGeneralMechanicalPlumbing
No filed description on record for this project.
On file for this project
6 documents · 3 drawing sheets
Removal and instillation of interior non load bearing partitions and related finishes. No change in use, egress or occupancy
On file for this project
4 documents · 12 drawing sheets
Modifications to existing plumbing/sprinkler fixtures as per plans filled herewith.
On file for this project
4 documents · 12 drawing sheets