← Back
Office with commercial, 7-19 stories
210 WEST 29 STREET
MANHATTAN · BIN 1014265
💬 Discuss this project
1924Year Built
9Stories
O6Building Class
M1-8A/R12Zoning
23,227 sfGross Floor Area
9Units
Rent Stabilized1 Open Violation ▸FISP: SAFE
Office with commercial, 7-19 stories · Owner of record: 210 WEST 29TH STREETCORP. · 2,475 sf lot · 9.38 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Roof1p · 1 filing · 19 docs
Floor 812p · 3 filings · 16 docs
Floor 7
Floor 6
Floor 5
Floor 41p · 1 filing · 19 docs
Floor 3
Floor 2
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW YORK CITY PRIME109/23/2026
32 EAST 31ST STREET1907/08/2026
BK CONSTRUCTIONDBA SRT CONSTRUCTION304/11/2026
U&Z CONSTRUCTION INC503/22/2026
210 WEST 29TH STREETCORP.103/22/2026
210 WEST 29TH STREET1803/22/2026
210 WEST 29 STREET403/22/2026
LONE STAT EQUITIES INC103/22/2026
DIAGONAL REALTY103/22/2026
210 W 29TH STREET ASSOC1303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MCHENERY TESTING LAB110/01/2024
ASHRAF CORP106/20/2024
JACK GREEN ASSOCIATES201/08/2024
ENV ARCHITECTS, DPC101/04/2024
PAKNIA ENGINEERING, PC206/03/2022
HARRY MELTZER ARCHITECT105/17/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PAKNIA ENGINEERING & ARCHITECTURE,603/21/2026
OUTSOURCE CONSULTANTS, INC.303/21/2026
BK CONSTRUCTIONDBA SRT CONSTRUCTION103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
U&Z CONSTRUCTION INCGeneral Contractor303/21/2026
ISTVAN DANCSElectrical103/21/2026
PSI PARTNERS, LLCFire Protection107/08/2026
AV BRAD CONSTRUCTION LLCGeneral Contractor107/08/2026
BK CONSTRUCTION SVCS INCGeneral Contractor104/11/2026
BRIGGS SERVICES LLCGeneral Contractor104/11/2026
NEW YORK CITY PRIME CORPGeneral Contractor109/23/2026
G.P. MECHANICAL CORPPlumbing107/08/2026
ALEXANDER EUGENEElectrical103/21/2026
IMPACT PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JACK GREEN ASSOCIATES422201/08/2024
PAKNIA ENGINEERING, PC1462206/01/2022
Building Lifecycle
All (77)Filed (8)Permit Issued (8)Signed Off (3)Facade (FISP) (12)Violation (36)Inspection (4)Special Inspection (6)
09/22/2026
Permit issued — Sidewalk Shed
M01462993-I1-SH
11/24/2025
Violation issued (HPD, closed)
I
12/03/2024
Violation issued (HPD, closed)
I
10/30/2024
Cycle 9 facade report signed — SAFE
10/21/2024
Cycle 9 facade report submitted
10/17/2024
Signed off — Alteration
PROPOSED INSTALLATION OF TEMPORARY LIGHT DUTY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01120512-I1
10/16/2024
Cycle 9 facade inspection completed
10/02/2024
Permit issued — Supported Scaffold
M01120512-I1-SF
10/01/2024
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY LIGHT DUTY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01120512-I1
06/21/2024
Permit issued — Sidewalk Shed
M01061026-I1-SH
06/20/2024
Filed — Alteration
M01061026-I1
04/25/2024
Violation issued (ECB, closed)
Local Law
03/05/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/23/2024
Permit issued — General Construction
M00980545-I1-GC
01/22/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/18/2024
Permit issued — Plumbing
M00980530-I1-EW-SP
01/16/2024
Permit issued — Sprinklers
M00980530-I1-PL
01/08/2024
Filed — Alteration
INTERIOR MECHANICAL WORK AS SHOWN HEREIWITH. NO CHANGES TO EGRESS, OCCUPANCY OR USE.
M00980539-I1
01/04/2024
Filed — Alteration
INTERIOR PLUMBING AND SPRINKLER ON 8TH FLOOR AS SHOWN HEREWITH. NO CHANGES TO EGRESS, OCCUPANCY OR USE.
M00980530-I1
01/04/2024
Filed — Alteration
INTERIOR DEMOLITION AND CONSTRUCTION OF NONLOAD BEARING PARTITIONS AND DOORS AS SHOWN HEREWITH. NO CHANGES TO EGRESS, OCCUPANCY OR USE.
M00980545-I1
01/04/2024
Special inspection requirement — Final
JACK GREEN
11/27/2023
Violation issued (HPD, closed)
I
02/22/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/02/2022
Signed off — Alteration
Installation of new 5-ton VRF system with rooftop condensing unit, two (2) indoor air handlers and associated ductwork, related piping and control wiring. Installation of ERV and associated ductwork for ventilation.
M00737598-I1
12/02/2022
Signed off — Alteration
Installation of new 5-ton VRF system with rooftop condensing unit, two (2) indoor air handlers and associated ductwork, related piping and control wiring. Installation of ERV and associated ductwork for ventilation.
M00737598-S1
11/16/2022
Violation issued (HPD, closed)
I
11/02/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/06/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/24/2022
Permit issued — Plumbing
M00737598-S1-PL
08/12/2022
Permit issued — General Construction
M00737598-I1-GC
06/03/2022
Filed — Alteration
Installation of new 5-ton VRF system with rooftop condensing unit, two (2) indoor air handlers and associated ductwork, related piping and control wiring. Installation of ERV and associated ductwork for ventilation.
M00737598-S1
06/01/2022
Filed — Alteration
Installation of new 5-ton VRF system with rooftop condensing unit, two (2) indoor air handlers and associated ductwork, related piping and control wiring. Installation of ERV and associated ductwork for ventilation.
M00737598-S2
05/18/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Edouard Paknia
05/18/2022
Special inspection requirement — Energy Code Compliance Inspections
Edouard Paknia
05/17/2022
Filed — Alteration
Installation of new 5-ton VRF system with rooftop condensing unit, two (2) indoor air handlers and associated ductwork, related piping and control wiring. Installation of ERV and associated ductwork for ventilation.
M00737598-I1
05/17/2022
Special inspection requirement — Mechanical Systems
Edouard Paknia
05/17/2022
Special inspection requirement — Final
Edouard Paknia
05/13/2022
Special inspection requirement — Final
Edouard Paknia
03/16/2022
Violation issued (HPD, closed)
I
04/21/2021
Violation issued (HPD, closed)
I
11/08/2019
Violation issued (HPD, closed)
I
09/03/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/07/2019
Cycle 8 facade report signed — SAFE
03/28/2019
Cycle 8 facade report submitted
03/07/2019
Cycle 8 facade inspection completed
02/11/2019
Violation issued (ECB, closed)
Local Law
07/31/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/11/2018
Violation issued (HPD, closed)
I
06/13/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/24/2014
Cycle 7 facade report submitted
06/19/2014
Cycle 7 facade report signed — SAFE
06/17/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/21/2014
Cycle 7 facade inspection completed
12/06/2013
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/30/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/06/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/18/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/16/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/20/2007
Cycle 6 facade report submitted
02/14/2007
Cycle 6 facade report signed — SAFE
Latest 60 of 77 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedNEW YORK CITY PRIME CORP09/22/2026
DOB NOWSupported ScaffoldSigned-offU&Z CONSTRUCTION INC10/02/2024
DOB NOWSidewalk ShedPermit IssuedBK CONSTRUCTION SVCS INC06/21/2024
DOB NOWGeneral ConstructionPermit IssuedBRIGGS SERVICES LLC02/23/2024
DOB NOWPlumbingPermit IssuedMORA FIRE PROTECTION LLC01/18/2024
DOB NOWSprinklersSigned-offIMPACT PLUMBING INC01/16/2024
DOB NOWPlumbingSigned-offG.P. MECHANICAL CORP09/24/2022
DOB NOWGeneral ConstructionSigned-offAV BRAD CONSTRUCTION08/12/2022
BISOTISSUEDBELLET CONSTRUCTION CO.IN09/10/2020
BISSPISSUEDKBM BRAND P AND H CO. INC06/14/2019
BISBLISSUEDCAM ENERGY HTG AND MECH02/01/2018
BISPLISSUEDMARATHON MECHANICAL LLC01/26/2018
BISOTISSUEDRESOURCE CONSTRUCTION COR01/22/2018
BISBLISSUEDCAM ENERGY HTG AND MECH01/27/2017
BISPLISSUEDMARATHON MECHANICAL LLC01/26/2017
BISOTISSUEDMARATHON ENERGY CORP01/26/2017
BISEQISSUEDREPUBLIC SCAFFOLD&HOIST C10/02/2012
BISPLISSUEDBARNETT PLBG & HTG CORP07/21/2009
BISPLISSUEDK B M BRAND08/14/2007
BISPLISSUEDBARNETT PLBG & HTG CORP01/13/2006
BIS—ISSUEDS&M PLUMBING & HEATING12/02/2005
BIS—ISSUEDMILASEN CONSTRUCTION INC12/03/2002
BIS—ISSUEDMILASEN CONSTRUCTION INC12/03/2002
BISOTISSUEDSTANDARD WATERPROOFING C06/02/2000
BISEQISSUEDT.B.R. INC.02/15/2000
2 projects · most recent 01/08/2024
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/08/2024——Air Conditioning Systems
Cooling
Mitsubishi Electric PEFY-P48NAMU-E 48,000 BTU · Vrf Indoor ×5
06/03/2022Signed-offAV BRAD CONSTRUCTION LLCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Lg ARUN060GSS4 5 tons · Vrf Outdoor ×1
Ventilation
Renewaire EV PREMIUM M 200 CFM · Erv ×1
1 project · most recent 01/04/2024
FiledStatusContractorScope
01/04/2024Permit IssuedPSI PARTNERS, LLC6 heads
2 projects · most recent 01/04/2024
Water/Sanitary
FiledStatusContractorScope
01/04/2024Signed-offIMPACT PLUMBING INCWater/Sanitary
06/03/2022Signed-offVERTEX PLUMBING & HTG CORWater/Sanitary
2 projects · most recent 06/28/2024
General Wiring
FiledStatusContractorScope
06/28/2024Permit IssuedHIGH QUALITY ELECTRIC OF—
11/01/2022CompleteVOLTAGE ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
03/05/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/22/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/02/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/06/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
01/04/2024FinalJACK GREENprogress
05/18/2022Fire-Resistant Penetrations and JointsEdouard Pakniaspecial
05/18/2022Energy Code Compliance InspectionsEdouard Pakniaprogress
05/17/2022Mechanical SystemsEdouard Pakniaspecial
05/17/2022FinalEdouard Pakniaprogress
05/13/2022FinalEdouard Pakniaprogress
▾Documents — 134 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/02/2026M00737598-S2Request digital key ↗
09/02/2026M00737598-I1Request digital key ↗
09/02/2026M00737598-S1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits21
▸BISWORK PERMIT APPLICATION11
09/15/2020140945814Open ↗
06/14/2019140853360Open ↗
02/01/2018140570870Open ↗
Showing 3 of 11 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION10
09/09/2020140945814Open ↗
06/10/2019140853360Open ↗
12/29/2017123265992Open ↗
Showing 3 of 10 on file for this type
▸Seals & Professional Certifications40
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/28/2026M00980545-I1Open ↗
08/28/2026M00980539-I1Open ↗
08/28/2026M00980539-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
09/25/2019140853360Open ↗
09/25/2019140853360Open ↗
03/29/2018140570870Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
09/09/2020140945814Open ↗
06/10/2019140853360Open ↗
12/29/2017123265992Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026M00980539-P1Open ↗
08/30/2026M00737598-I1Open ↗
08/25/2026M00737598-S2Open ↗
Showing 3 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
09/09/2020140945814Open ↗
06/10/2019140853360Open ↗
12/30/2016140570870Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
12/29/2017123265992Open ↗
09/01/2017123137211Open ↗
10/03/2012121376117Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
09/09/2020140945814Open ↗
06/10/2019140853360Open ↗
12/30/2016140570870Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026M00980539-P1Open ↗
08/25/2026M00737598-S2Open ↗
08/25/2026M00737598-S2Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/03/2012121376117Open ↗
▸Trade Schedules & Equipment6
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
09/01/2017123137211Open ↗
08/16/2017140570870Open ↗
08/09/2017140570870Open ↗
▸BISSCHEDULE B - PLUMBING2
06/10/2019140853360Open ↗
12/30/2016140570870Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
12/30/2016140570870Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
09/09/2020140945814Open ↗
▸Environmental & Asbestos23
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/28/2026M00980545-I1Open ↗
08/28/2026M00980539-P1Open ↗
08/28/2026M00980539-I1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)5
09/09/2020140945814Open ↗
06/10/2019140853360Open ↗
12/29/2017123265992Open ↗
Showing 3 of 5 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED5
09/09/2020140945814Open ↗
06/10/2019140853360Open ↗
01/19/2018123265992Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWOER: Notice to Proceed4
08/13/2026M00980545-I1Open ↗
08/13/2026M00737598-I1Open ↗
08/13/2026M00737598-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWOER: Notice of Satisfaction2
08/13/2026M00737598-S1Open ↗
08/13/2026M00737598-I1Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
03/29/2018140570870Open ↗
12/29/2017123265992Open ↗
10/03/2017123137211Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
09/09/2020140945814Open ↗
12/30/2016140570870Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
09/09/2020140945814Open ↗
12/30/2016140570870Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
03/29/2018140570870Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
09/10/2020140945814Open ↗
09/09/2020140945814Open ↗
12/30/2016140570870Open ↗
▸Approvals, Objections & Sign-offs6
▸BISLETTERS - SUPPORTING DOCUMENTATION3
03/29/2018140570870Open ↗
03/29/2018140570870Open ↗
11/13/2017123137211Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
10/08/2019140853360Open ↗
03/29/2018140570870Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
10/03/2012121376117Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
09/09/2020140945814Open ↗
06/10/2019140853360Open ↗
03/29/2018140570870Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms10
▸BISEFILING COVER SHEET4
12/29/2017123265992Open ↗
09/11/2017123137211Open ↗
09/01/2017123137211Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
09/09/2020140945814Open ↗
06/10/2019140853360Open ↗
12/30/2016140570870Open ↗
▸BISBOROUGH INTAKE FORM2
10/08/2019140853360Open ↗
03/29/2018140570870Open ↗
▸BISADDITIONAL INFORMATION1
07/17/2019140853360Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
10/08/2019140853360Open ↗