DOB11/14/2025Violation issued-failure to file 2024 internal hgh pressure inspection
DOB11/14/2025Violation issued-failure to file 2024 external low pressure inspection
DOB11/14/2025Violation issued-failure to file 2024 external hgh pressure inspection
DOB10/09/2025Ftm bldg in a safe condition-bldg exterior walls @ EXP1,2,3, have step horizontal & vert cracks in multiple locations incl corners& doors/ windows lintels.a parapet cap @ EXP3 severely deteriorated.owner to retain nyspe to eval entire bldg & parking lot wall & file repr dwgs w/DOB bldg t/be repaired under permit
DOB10/09/2025Failure to maintain bldg in a code complaint manner.annual parapet observation report,obsrvd several crcks in brick&mortar at parapet on all exps.obsrvd vert crcks@ 1/2 crnr,2/3 crnr& 1/4 crnr.submit annual parapet obsvrtn for 2024 to be received by DOB no later than 10/23/25 sbmt rprt to forensiceng@buildings.NYC.gov
DOB10/08/2025Adjacent brick wall at exp 4 to section that collapse also has cracks and has the potential to collapse as well. Main building has step cracks at all exposure from ground floor to roof level.
DOB09/23/2024Violation issued-failure to file 2023 internal hgh pressure inspection
DOB09/23/2024Violation issued-failure to file 2023 external low pressure inspection2 identical filings
DOB09/23/2024Violation issued-failure to file 2023 external hgh pressure inspection
ECB03/30/2021As per one weil mc lain boiler with valve capacity 360 lb/hr. Serial and model numbers blotted out. Boiler not registered., maintain boiler; register boiler, correct all violating conditions call for an inspectNothing owed — awaiting certificate of correction
ECB03/30/2021As per one teledyne laars boiler in cellar of laundromat. Serial number C98B00390. Boiler not registered., maintain boiler; register boiler, correct all violating conditions, call for an inspection.Nothing owed — awaiting certificate of correction
Likely answered · the city's own records show a filing, but DOB's feed still lists these as active
DOB06/30/2023Violation issued-failure to file 2020 internal hgh pressure inspectionAnswered on the city's records: a 2020 boiler inspection report was accepted (Aug 19, 2020)
DOB06/30/2023Violation issued-failure to file 2021 external hgh pressure inspectionAnswered on the city's records: a 2021 boiler inspection report was accepted (Oct 7, 2021)
DOB06/30/2023Violation issued-failure to file 2021 internal hgh pressure inspectionAnswered on the city's records: a 2021 boiler inspection report was accepted (Oct 7, 2021)
DOB06/30/2023Violation issued-failure to file 2020 external hgh pressure inspectionAnswered on the city's records: a 2020 boiler inspection report was accepted (Aug 19, 2020)
DOB06/20/2023Violation issued-failure to file 2018 external hgh pressure inspectionAnswered on the city's records: a 2018 boiler inspection report was accepted (Nov 7, 2018)
DOB06/20/2023Violation issued-failure to file 2019 external hgh pressure inspectionAnswered on the city's records: a 2019 boiler inspection report was accepted (Nov 13, 2019)
DOB06/20/2023Violation issued-failure to file 2019 internal hgh pressure inspectionAnswered on the city's records: a 2019 boiler inspection report was accepted (Nov 13, 2019)
DOB06/20/2023Violation issued-failure to file 2018 internal hgh pressure inspectionAnswered on the city's records: a 2018 boiler inspection report was accepted (Nov 7, 2018)
DOB04/25/2023Violation issued-failure to file 2022 internal high pressure inspectionAnswered on the city's records: a 2022 boiler inspection report was accepted (Oct 4, 2022)
DOB04/25/2023Violation issued-failure to file 2022 external high pressure inspectionAnswered on the city's records: a 2022 boiler inspection report was accepted (Oct 4, 2022)
DOB03/16/2020Violation issued - failure to file 2017 external high pressure boiler inspectionAnswered on the city's records: a 2017 boiler inspection report was accepted (Oct 10, 2017)
DOB03/16/2020Violation issued - failure to file 2017 internal high pressure boiler inspectionAnswered on the city's records: a 2017 boiler inspection report was accepted (Oct 10, 2017)
DOB06/22/2018Violation issued for failure to file 2016 annual high pressure boiler inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2022). This one is not shown as answered
One story retail building · Owner of record: C Plus Realty · 14,400 sf lot · 0.61 FAR built · Flood zone X