← Back
Public elementary, junior or senior high
P.S. 91 Bronx
2170 AQUEDUCT AVENUE EAST · BIN 2094683
💬 Discuss this project
1929Year Built
4Stories
W1Building Class
R7-1Zoning
79,241 sfGross Floor Area
1Units
LL97 Covered79 Open Violations 60 unresolved · 19 paperwork only ▸
Public elementary, junior or senior high · Owner of record: NYC DEPARTMENT OF EDUCATION · 48,241 sf lot · 1.64 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbing
Roof3p · 2 filings · 20 docs
Bulkhead1p · 1 filing · 20 docs
Floor 44p · 1 filing · 20 docs
Floor 310p · 2 filings · 20 docs
Floor 23p · 1 filing · 20 docs
Floor 13p · 2 filings · 20 docs
Cellar6p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DOE303/22/2026
DEPT. OF EDUCATION PS 91803/22/2026
PS 91 DOE1603/22/2026
DEPARTMENT OF EDUCATION503/22/2026
DOE PS 91 040403/22/2026
DOE 040303/22/2026
AQUEDUCT REALTY103/22/2026
PS 91 DOE 04203/22/2026
PS 91 DEPT OF ED203/22/2026
BOARD OF EDUCATION PS 91203/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
STEPHEN B JACOBS GROUP803/21/2026
JMV ASSOCIATES2003/21/2026
DSENY ENGINEERING SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EMPIRE CONTROL ABATEMENTGeneral Contractor807/08/2026
KEL-TECH CONSTRUCTION INCGeneral Contractor307/08/2026
JOSHUA ANDERSONElectrical103/21/2026
RISHI BUNSEEElectrical103/21/2026
STANCO SYSTEM ELEC'L CONTElectrical103/22/2026
STEPHEN BULFAROElectrical103/21/2026
CHARAN ELEC'L ENTERP'S INElectrical103/22/2026
I.M.P. PLBG. & HTG. CORPPlumbing107/08/2026
DVM ELECTRICAL SERVICES LElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TWIN PEAKS INC.317608/23/2023
Building Lifecycle
All (164)Filed (24)Permit Issued (10)Signed Off (3)Violation (60)Inspection (5)Objection (32)Special Inspection (30)
08/11/2026
Violation issued (HPD, open)
A
08/11/2026
Violation issued (HPD, open)
A
08/05/2026
Violation issued (HPD, open)
A
08/05/2026
Violation issued (HPD, open)
C
08/05/2026
Violation issued (HPD, open)
A
08/05/2026
Violation issued (HPD, open)
A
08/05/2026
Violation issued (HPD, open)
A
08/05/2026
Violation issued (HPD, open)
B
08/05/2026
Violation issued (HPD, open)
A
07/28/2026
Violation issued (ECB, open)
Construction
07/28/2026
Violation issued (ECB, open)
Construction
07/28/2026
Violation issued (ECB, open)
Construction
07/28/2026
Violation issued (ECB, open)
Construction
07/28/2026
Violation issued (ECB, open)
Construction
04/08/2026
Violation issued (HPD, closed)
C
04/08/2026
Violation issued (HPD, closed)
B
04/08/2026
Violation issued (HPD, open)
C
03/29/2026
Violation issued (HPD, closed)
B
03/29/2026
Violation issued (HPD, closed)
C
03/29/2026
Violation issued (HPD, closed)
C
03/29/2026
Violation issued (HPD, closed)
B
03/09/2026
Special inspection requirement — Fenestration air leakage
03/09/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
03/09/2026
Special inspection requirement — Air barrier - visual inspection
03/09/2026
Special inspection requirement — Sprayed fire-resistant materials
03/09/2026
Special inspection requirement — Masonry
03/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/09/2026
Special inspection requirement — Energy Code Compliance Inspections
03/09/2026
Special inspection requirement — Insulation placement and R values
02/26/2026
Objection resolved — Addressed
02/20/2026
Objection raised — Other
02/19/2026
Special inspection requirement — Interior lighting power
02/18/2026
Filed — Alteration
P.S. 091-X: Roof replacement, parapet replacement, window replacement, exterior wall repairs and maintenance.
X01008215-P1
02/18/2026
Special inspection requirement — Masonry
02/17/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
02/17/2026
Special inspection requirement — Fenestration air leakage
02/17/2026
Special inspection requirement — Energy Code Compliance Inspections
02/17/2026
Special inspection requirement — Insulation placement and R values
02/17/2026
Special inspection requirement — Sprayed fire-resistant materials
02/17/2026
Special inspection requirement — Air barrier - visual inspection
02/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/17/2026
Special inspection requirement — Masonry
02/12/2026
Violation issued (HPD, closed)
B
02/12/2026
Violation issued (HPD, closed)
B
01/12/2026
Permit issued — Sidewalk Shed
X00953311-I1-SH
01/02/2026
Special inspection requirement — Masonry
11/24/2025
Violation issued (HPD, closed)
C
11/24/2025
Violation issued (HPD, closed)
C
11/18/2025
Objection raised — Other
11/18/2025
Objection resolved — Addressed
11/18/2025
Objection raised — Other
11/18/2025
Objection resolved — Addressed
11/18/2025
Objection raised — Other
11/18/2025
Objection resolved — Addressed
11/18/2025
Objection raised — Other
11/18/2025
Objection resolved — Addressed
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/06/2025
Filed — Alteration
PA 091X: Removal of floor mounted unit ventilators, radiators and associated piping. Installation of new air-cooled chiller, new unit ventilators, new floor mounted unit ventilators, new steam fin-tube radiation and all associated piping.
X01312701-S2
11/06/2025
Filed — Alteration
PA 091X: Removal of floor mounted unit ventilators, radiators and associated piping. Installation of new air-cooled chiller, new unit ventilators, new floor mounted unit ventilators, new steam fin-tube radiation and all associated piping.
X01312701-S3
Latest 60 of 164 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedKEL-TECH CONSTRUCTION INC01/12/2026
DOB NOWSidewalk ShedPermit IssuedKEL-TECH CONSTRUCTION INC01/15/2025
DOB NOWSidewalk ShedPermit IssuedKEL-TECH CONSTRUCTION INC01/19/2024
DOB NOWGeneral ConstructionSigned-offEMPIRE CONTROL ABATEMENT07/28/2023
DOB NOWGeneral ConstructionPermit IssuedEMPIRE CONTROL ABATEMENT07/28/2023
DOB NOWPlumbingSigned-offI.M.P. PLBG. & HTG. CORP09/09/2022
DOB NOWGeneral ConstructionSigned-offEMPIRE CONTROL ABATEMENT08/31/2022
DOB NOWGeneral ConstructionSigned-offEMPIRE CONTROL ABATEMENT07/06/2022
DOB NOWGeneral ConstructionPermit IssuedEMPIRE CONTROL ABATEMENT06/24/2022
DOB NOWGeneral ConstructionPermit IssuedEMPIRE CONTROL ABATEMENT06/06/2022
BISPLISSUEDVARSITY PLBG AND HTG INC01/17/2023
BISOTISSUEDMDS CONSTRUCTION MANAGE04/28/2022
BISOTISSUEDMDS CONSTRUCTION MANAGE04/18/2022
BISOTISSUEDMDS CONSTRUCTION MANAGE02/15/2022
BISPLISSUEDVARSITY PLBG AND HTG INC01/21/2022
BISOTISSUEDMDS CONSTRUCTION MANAGE01/21/2022
BISOTISSUEDHIGH VOLT ELECTRIC CORP O09/02/2016
BISOTISSUEDAMB CONTRACTORS INC08/24/2016
BISOTISSUEDAMB CONTRACTORS INC08/04/2016
BISOTISSUEDAMB CONTRACTORS INC07/14/2016
BISOTISSUEDHIGH VOLT ELECTRIC CORP O07/14/2016
BISOTISSUEDAMB CONTRACTORS INC07/14/2016
BISMHISSUEDCENTRAL MECHANICAL SYSTEMS INC03/24/2015
BISMHISSUEDCENTRAL MECHANICAL SYSTEMS INC09/26/2014
BISOTISSUEDNAVILLUS TILE INC08/01/2014
BISOTISSUEDNAVILLUS TILE INC08/01/2014
BISEQISSUEDNAVILLUS TILE INC12/31/2008
BISEQISSUEDNAVILLUS TILE INC12/30/2008
BISEQISSUEDNAVILLUS TILE INC12/30/2008
BISOTISSUEDNAVILLUS CONTRACTING10/15/2008
BISEQISSUEDNAVILLUS CONTRACTING12/31/2007
BISEQISSUEDNAVILLUS CONTRACTING12/31/2007
BISEQISSUEDNAVILLUS CONTRACTING12/31/2007
BISEQISSUEDNAVILLUS CONTRACTING10/17/2007
BISMHISSUEDJ&A CONTRACTORS CORPORATION10/17/2007
BISOTISSUEDNAVILLUS CONTRACTING10/17/2007
BISOTISSUEDNAVILLUS CONTRACTING10/17/2007
BISEQISSUEDNAVILLUS CONTRACTING10/02/2007
BISEQISSUEDNAVILLUS CONTRACTING10/02/2007
BISOTISSUEDNW PIPING & WELDING INCORPORATED03/07/2007
+ 17 more permits on file
2 projects · most recent 02/18/2026
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/18/2026——Air Conditioning Systems
Cooling
Mitsubishi Electric PKA-A30KA7 30 BTU · Vrf Indoor ×4
PUZ-HA30NHA5 30 BTU · Split System ×4
11/06/2025——Air Conditioning Systems, Ventilation Systems
Cooling
Bell & Gossett E-1510 3EB 1,800 kW · Pump ×2
Lg LSN243HLV3 26,000 BTU · Vrf Indoor ×1
LSU243HLV3 26,000 BTU · Heat Pump Outdoor ×1
Jetson ACCM-030-F-B-G-2-1 145 tons · Air Cooled Chiller ×1
Ventilation
Airedale ZFF1500 1,500 CFM · Vav Box ×24
ZFF1250 1,250 CFM · Vav Box ×12
ZFF1000 1,000 CFM · Vav Box ×2
ZFF750 750 CFM · Vav Box ×1
Loren Cook 150 SQ1H 150 SQ1HP 300 CFM · Exhaust Fan ×1
Magic-Aire ZFF1500 1,500 CFM · Vav Box ×1
3 projects · most recent 02/18/2026
Storm Water/Sanitary Gas
FiledStatusContractorScope
02/18/2026——Storm
11/06/2025——Gas, Water/Sanitary
10/31/2024——Storm, Water/Sanitary
12 projects · most recent 04/26/2025
General Wiring Lighting
FiledStatusContractorScope
04/26/2025CompleteDVM ELECTRICAL SERVICES LLighting
03/31/2025CompleteANCO ELECTL CONTCTNG INC—
01/05/2024Permit IssuedSTANCO SYSTEM ELEC'L CONT—
10/18/2022CompleteKLK ELECTRIC, INCGeneral Wiring
08/05/2022Permit IssuedGEMINI ELECTRIC CO., INC.Lighting
07/11/2022CompleteKLK ELECTRIC, INCGeneral Wiring
07/11/2022CompleteKLK ELECTRIC, INCGeneral Wiring
06/02/2022CompleteURBAN ELECTRICAL CORPGeneral Wiring
07/12/2021CompleteDORION NORTON ELECL CONTGeneral Wiring
08/05/2020CompleteCHARAN ELEC'L ENTERP'S IN—
11/27/2019CompleteCHARAN ELEC'L ENTERP'S IN—
11/21/2018CompleteCHARAN ELEC'L ENTERP'S IN—
2 projects · most recent 02/18/2026
Steel Concrete
FiledStatusContractorScope
02/18/2026——Steel, Concrete
11/06/2025——Steel, Concrete
1 project · most recent 12/06/2023
Sidewalk Shed
FiledStatusContractorScope
12/06/2023Permit IssuedKEL-TECH CONSTRUCTION INCSidewalk Shed
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/27/2025Pass-Final General Construction Non-Directive 14PassView ↗
10/02/2024Pass-Final General Construction Non-Directive 14PassView ↗
04/26/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/30/2024Pass-Final CND-Occupancy InspectionPassView ↗
11/17/2022Pass-Final PL - Up to 9 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 81
DateRequirementInspectorRole
03/09/2026Fenestration air leakage—energy_progress
03/09/2026Masonry—special
03/09/2026Sprayed fire-resistant materials—special
03/09/2026Fenestration and door U-factor and product ratings—energy_progress
03/09/2026Fire-Resistant Penetrations and Joints—special
03/09/2026Energy Code Compliance Inspections—progress
03/09/2026Air barrier - visual inspection—energy_progress
03/09/2026Insulation placement and R values—energy_progress
02/19/2026Interior lighting power—energy_progress
02/18/2026Masonry—special
02/17/2026Fire-Resistant Penetrations and Joints—special
02/17/2026Masonry—special
02/17/2026Sprayed fire-resistant materials—special
02/17/2026Energy Code Compliance Inspections—progress
02/17/2026Fenestration and door U-factor and product ratings—energy_progress
02/17/2026Fenestration air leakage—energy_progress
02/17/2026Air barrier - visual inspection—energy_progress
02/17/2026Insulation placement and R values—energy_progress
01/02/2026Masonry—special
11/06/2025Duct leakage testing, insulation and design—energy_progress
11/06/2025HVAC-R and service water heating equipment—energy_progress
11/06/2025HVAC-R and service water heating system controls—energy_progress
11/06/2025HVAC-R and service water piping design and insulation—energy_progress
11/06/2025Maintenance information—energy_progress
11/06/2025Shutoff dampers—energy_progress
Latest 25 of 81.
▾Documents — 165 on file (BIS + DOB NOW)
▸Plans & Drawings23
▸DOB NOWPlans/Sketch23
08/25/2026X00635967-P2Request digital key ↗
08/25/2026X00635967-P1Request digital key ↗
08/24/2026X00692096-P3Request digital key ↗
Showing 3 of 23 on file for this type
▸Seals & Professional Certifications42
▸DOB NOWDPL-1: Design Professional Seal & Signature23
08/25/2026X00635967-P2Open ↗
08/25/2026X00635967-P1Open ↗
08/25/2026X00635967-I1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/05/2026X00638846-I1Open ↗
09/05/2026X00638846-I1Open ↗
09/05/2026X00638846-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/05/2026X00638846-I1Open ↗
09/05/2026X00638846-I1Open ↗
08/27/2026X00635967-P1Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWNYCSCA - Approved Site Safety Plans1
08/13/2026X00953311-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/25/2026X00635967-P2Open ↗
08/25/2026X00635967-P1Open ↗
08/24/2026X00692096-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/15/2026X00638846-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026X00635967-I1Open ↗
▸Approvals, Objections & Sign-offs56
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)24
08/25/2026X00635967-P1Open ↗
08/15/2026X01008215-S2Open ↗
08/15/2026X01008215-S3Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter23
08/25/2026X00635967-P2Open ↗
08/25/2026X00635967-P1Open ↗
08/15/2026X00635967-I1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)8
08/13/2026X00692096-S1Open ↗
08/13/2026X00638846-I1Open ↗
08/13/2026X01094861-S4Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDEP Variance (V5) letter1
08/13/2026X00638846-I1Open ↗
▸Filing & Intake Forms3
▸DOB NOWAI1 Form3
08/13/2026X00692096-I1Open ↗
08/13/2026X00638846-I1Open ↗
08/13/2026X00635967-I1Open ↗
▸Other Documents30
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal24
08/25/2026X00635967-P1Open ↗
08/15/2026X01008215-S2Open ↗
08/15/2026X01008215-S3Open ↗
Showing 3 of 24 on file for this type
▸DOB NOWNYCSCA Exhibit 23
08/13/2026X00635967-I1Open ↗
08/13/2026X00692096-I1Open ↗
08/13/2026X00692096-S1Open ↗
▸DOB NOWWaiver Document2
08/13/2026X00635967-I1Open ↗
08/13/2026X00635967-P2Open ↗
▸DOB NOWFee Exempt Supporting Document - DOF Property Tax Assessment Roll1
08/13/2026X00953311-I1Open ↗