← Back
Public elementary, junior or senior high
P.S. 84 Steinway
22-41 41 STREET · Astoria (North)-Ditmars-Steinway · BIN 4015334
💬 Discuss this project
1930Year Built
3Stories
W1Building Class
R5Zoning
59,856 sfGross Floor Area
1Units
LL97 Covered2 Open Violations 0 unresolved · 2 paperwork only ▸
Public elementary, junior or senior high · Owner of record: NYC DEPARTMENT OF EDUCATION · 50,005 sf lot · 1.2 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof4p · 1 filing · 20 docs
Floor 31p · 1 filing · 20 docs
Floor 2
Floor 1
Basement4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC SCHOOL CONSTRUCTION1109/14/2026
NYC DEPARTMENT OF EDUCATION103/22/2026
DEPARTMENT OF EDUCATION 0103/22/2026
DEPARTMENT OF EDUCATION503/22/2026
DOE 040403/22/2026
D.O.E. P.S.084303/22/2026
DOE PS 84 040203/22/2026
P.S. 84 D.O.E.403/22/2026
P.S. 84 DEPT. OF EDUCATIO103/22/2026
BD OF EDUCATION P.S. 040203/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GANNETT FLEMING ENGINEERS & ARCHITE603/21/2026
NELLIGAN WHITE ARCHITECTS1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
G ENERGY SOLTN AND SVCS IElectrical103/22/2026
JAMES MAGRIPLESElectrical103/21/2026
JOHN JR MARIElectrical103/21/2026
MAGRIPLES JAMESElectrical103/21/2026
NIEVES WILLIAMElectrical103/21/2026
WILLIAM NIEVESElectrical103/21/2026
Building Lifecycle
All (107)Filed (16)Violation (50)Objection (11)Special Inspection (30)
09/10/2026
Objection raised — Other
08/31/2026
Filed — Alteration
FN/PS84Q - FOR TEMPORARY CONSTRUCTION EQUIPMENT(FENCE) SUBMITTING ON BEHALF OF CONTRACTOR, RELATED TO DOB #Q00924790 NO CHANGE IN USE, OCCUPANCY OR EGRESS
Q01442233-I1
07/02/2026
Filed — Alteration
Q00924790-P6
07/02/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
07/02/2026
Special inspection requirement — Subgrade Inspections
07/02/2026
Special inspection requirement — Energy Code Compliance Inspections
07/02/2026
Special inspection requirement — Masonry
07/02/2026
Special inspection requirement — Fenestration areas
07/02/2026
Special inspection requirement — Air barrier - visual inspection
07/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/02/2026
Special inspection requirement — Fenestration air leakage
07/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
07/02/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
07/02/2026
Special inspection requirement — Final
07/02/2026
Special inspection requirement — Insulation placement and R values
06/24/2026
Special inspection requirement — Fenestration air leakage
06/24/2026
Special inspection requirement — Insulation placement and R values
06/24/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
06/24/2026
Special inspection requirement — Energy Code Compliance Inspections
06/24/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
06/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/24/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/24/2026
Special inspection requirement — Fenestration areas
06/24/2026
Special inspection requirement — Subgrade Inspections
06/24/2026
Special inspection requirement — Masonry
06/24/2026
Special inspection requirement — Final
06/24/2026
Special inspection requirement — Air barrier - visual inspection
04/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
04/02/2026
Special inspection requirement — Exterior lighting power
04/02/2026
Special inspection requirement — Shutoff dampers
04/02/2026
Special inspection requirement — Energy Code Compliance Inspections
04/02/2026
Special inspection requirement — Final
04/02/2026
Special inspection requirement — Duct leakage testing, insulation and design
03/26/2026
Filed — Alteration
Q00924790-P5
03/18/2026
Objection resolved — Addressed
03/18/2026
Objection resolved — Addressed
02/13/2026
Violation issued (ECB, open)
Construction
01/23/2026
Objection resolved — Addressed
01/23/2026
Objection resolved — Addressed
01/23/2026
Objection resolved — Addressed
12/01/2025
Filed — Alteration
Q00924790-P3
12/01/2025
Filed — Alteration
Q00924790-P4
11/26/2025
Filed — Alteration
Q00924790-P1
11/26/2025
Filed — Alteration
Q00924790-P2
08/08/2025
Objection raised — Other
08/08/2025
Objection raised — Other
08/08/2025
Objection raised — Other
08/08/2025
Objection raised — Other
08/08/2025
Objection raised — Other
08/06/2025
Filed — Alteration
Replacement of sub-basement, basement and kitchen light fixtures due to basement floor slab replacement.
Q01246163-S3
08/06/2025
Filed — Alteration
Replacement of sub-basement, basement and kitchen light fixtures due to basement floor slab replacement.
Q01246163-S4
08/06/2025
Filed — Alteration
Replacement of sub-basement, basement and kitchen light fixtures due to basement floor slab replacement.
Q01246163-S2
07/29/2025
Filed — Alteration
Replacement of sub-basement, basement and kitchen light fixtures due to basement floor slab replacement.
Q01246163-S1
07/20/2025
Filed — Alteration
Replacement of sub-basement, basement and kitchen light fixtures due to basement floor slab replacement.
Q01246163-I1
03/18/2025
Violation issued (ECB, open)
Construction
02/23/2024
Violation issued (ECB, closed)
Construction
02/23/2024
Violation issued (ECB, closed)
Construction
08/28/2023
Filed — Alteration
Q00924790-S3
08/28/2023
Filed — Alteration
Q00924790-S1
08/28/2023
Filed — Alteration
Q00924790-S2
Latest 60 of 107 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDNOBLE ELECTRICAL CONTR CO06/28/2013
BISOTISSUEDADAM'S EUROPEAN CONTRACTING06/10/2010
BISPLISSUEDVARSITY PLBG AND HTG INC07/08/2009
BISOTISSUEDADAM'S EUROPEAN CONTRACTING06/30/2009
BISEQISSUEDMETRO. BRIDGE & SCAF. COR06/19/2009
BISEQISSUEDMETROPOLITAN BRIDGE & SCAFOLDS06/16/2008
BISEQISSUEDADAM'S EUROPEAN CONTRACTING06/12/2008
BISEQISSUEDADAM'S EUROPEAN CONTRACTING06/12/2008
BISEQISSUEDLIBERTY ARCHITECTURAL PRODUCTS07/27/2006
BISOTISSUEDVENUS ELECTRICAL CONTRACTORS INC02/16/2005
BISPLISSUEDPROGRAM UNLIMITED PLUMBING AND11/26/2003
BISMHISSUEDPROGRAM UNLIMITED PLUMBING AND11/26/2003
BISOTISSUEDFIRTCH CONSTRUCTION CO INC09/22/2003
BISOTISSUEDFIRTCH CONSTRUCTION CO INC09/22/2003
BISEQISSUEDSPRING SCAFFOLDING04/07/2003
BISOTISSUEDFIRTCH CONSTRUCTION CO INC09/16/2002
BISMHISSUEDPROGRAM UNLIMITED PLUMBING AND09/16/2002
BISOTISSUEDFIRTCH CONSTRUCTION CO INC09/16/2002
BISPLISSUEDPROGRAM UNLIMITED PLUMBING AND09/16/2002
BISOTISSUEDPHOENIX SERVICES CORPORATION09/12/2002
BISEQISSUEDSPRING SCAFFOLDING08/13/2002
BISFBISSUEDDOUGLAS SIMMONS06/27/2000
BISPLISSUEDNY PLUMBING & SPRINKLER CORP06/27/2000
BISOTISSUEDRAKENS INCORPORATED05/22/2000
BISOTISSUEDRAKENS INCORPORATED05/22/2000
BISOTISSUEDMARIC MECHANICAL INC07/02/1999
BISFBISSUEDDOUGLAS SIMMONS06/25/1999
BISPLISSUEDNY PLUMBING & SPRINKLER CORP06/25/1999
BISEQISSUEDMARIC MECHANICAL INC06/16/1999
BISOTISSUEDRAKENS INCORPORATED01/21/1998
BISOTISSUEDRAKENS INCORPORATED01/21/1998
BISOTISSUEDR.BATTLE CONSTRUCTION CORP.10/04/1993
1 project · most recent 08/06/2025
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/06/2025——Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Lg ARUM072BTE5 72,000 BTU · Vrf Outdoor ×1
KNUDB121A 335 CFM · Vrf Outdoor ×1
KUSXB121A 11,100 BTU · Condensing Unit ×1
ZRUM072BTE6 72,000 BTU · Vrf Outdoor ×1
Heating
Ouellet OAS02038AM 2 kW · Electric Heater ×3
Qmark CDF-RE-558 5 kW · Electric Heater ×2
Thermolec MSC0-10LS-1002-0000 7 kW · Electric Heater ×1
Ventilation
Greenheck G-098-VG 450 CFM · Exhaust Fan ×2
SQ-120-VG 1,250 CFM · Exhaust Fan ×1
SQ-98-VG 300 CFM · Exhaust Fan ×1
USF-12 1,225 CFM · Kitchen Exhaust ×1
Vts AVS012-R-FHCV 1,100 CFM · Makeup Air ×1
1 project · most recent 08/06/2025
FiledStatusContractorScope
08/06/2025——4 heads
1 project · most recent 08/06/2025
Gas Plumbing-Sprinkler Water/Sanitary
FiledStatusContractorScope
08/06/2025——Gas, Plumbing-Sprinkler, Water/Sanitary
4 projects · most recent 08/23/2022
General Wiring
FiledStatusContractorScope
08/23/2022Permit IssuedG ENERGY SOLTN AND SVCS IGeneral Wiring
09/18/2020CompleteURBAN ELECTRICAL CORPGeneral Wiring
10/18/2019CompleteCHARAN ELEC'L ENTERP'S INGeneral Wiring
09/23/2019CompleteSTATIC ELECTRIC CORPGeneral Wiring
1 project · most recent 08/06/2025
Steel Concrete
FiledStatusContractorScope
08/06/2025——Steel, Concrete
1 project · most recent 08/31/2026
Fence
FiledStatusContractorScope
08/31/2026——Fence
▾Special Inspection Requirements (DOB NOW) — 97
DateRequirementInspectorRole
07/02/2026Final—progress
07/02/2026Fenestration and door U-factor and product ratings—energy_progress
07/02/2026Insulation placement and R values—energy_progress
07/02/2026Fenestration areas—energy_progress
07/02/2026Fenestration air leakage—energy_progress
07/02/2026Air barrier - visual inspection—energy_progress
07/02/2026Subgrade Inspections—special
07/02/2026Structural Stability – Alterations of existing buildings—special
07/02/2026Masonry—special
07/02/2026Wall Panels, Curtain Walls, and Veneers—special
07/02/2026Fire-Resistance Rated Construction—progress
07/02/2026Energy Code Compliance Inspections—progress
06/24/2026Fenestration air leakage—energy_progress
06/24/2026Insulation placement and R values—energy_progress
06/24/2026Air barrier - visual inspection—energy_progress
06/24/2026Fenestration areas—energy_progress
06/24/2026Fenestration and door U-factor and product ratings—energy_progress
06/24/2026Fire-Resistance Rated Construction—progress
06/24/2026Final—progress
06/24/2026Energy Code Compliance Inspections—progress
06/24/2026Wall Panels, Curtain Walls, and Veneers—special
06/24/2026Subgrade Inspections—special
06/24/2026Structural Stability – Alterations of existing buildings—special
06/24/2026Masonry—special
04/02/2026HVAC-R and service water piping design and insulation—energy_progress
Latest 25 of 97.
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
09/14/2026Q01442233-I1Request digital key ↗
08/24/2026Q00924790-I1Request digital key ↗
08/24/2026Q00924790-S2Request digital key ↗
Showing 3 of 14 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
09/15/2010420250418Open ↗
▸Seals & Professional Certifications21
▸DOB NOWDPL-1: Design Professional Seal & Signature18
09/14/2026Q01442233-I1Open ↗
08/24/2026Q00924790-I1Open ↗
08/24/2026Q00924790-S2Open ↗
Showing 3 of 18 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/15/2010420250418Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/15/2010420250418Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/15/2010420250418Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
09/15/2010420250418Open ↗
▸Approvals, Objections & Sign-offs26
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter14
09/14/2026Q01442233-I1Open ↗
08/24/2026Q00924790-S2Open ↗
08/24/2026Q00924790-S1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)11
09/14/2026Q01442233-I1Open ↗
08/24/2026Q00924790-S2Open ↗
08/24/2026Q00924790-P6Open ↗
Showing 3 of 11 on file for this type
▸BISADMINISTRATIVE OBJECTIONS1
09/15/2010420250418Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/15/2010420250418Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/15/2010420250418Open ↗
▸Other Documents20
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal19
09/14/2026Q01442233-I1Open ↗
08/24/2026Q00924790-I1Open ↗
08/24/2026Q00924790-S2Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF Property Tax Assessment Roll1
08/13/2026Q01246163-S1Open ↗