← Back
Two family converted from one family
22-66 24 STREET
QUEENS · Astoria (North)-Ditmars-Steinway · BIN 4468958
💬 Discuss this project
1920Year Built
2Stories
B3Building Class
R5BZoning
1,326 sfGross Floor Area
2Units
Two family converted from one family · 2,000 sf lot · 0.66 FAR built · Flood zone X
Locations of Work
Structural
Roof1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
95 MORGAN PROPERTIES703/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/15/2019$1.3M—THE THOMAS FACATSELIS SUPPLEMENTAL NEEDS TRUST → Private party$967/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DEMERARA ENGINEERING, PLLC312/01/2021
MICHAEL ALMON, ARCHITECT101/08/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KJH BUILDING & DEV CORPGeneral Contractor603/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DEMERARA ENGINEERING, PLL4248412/01/2021
MICHAEL ALMON, ARCHITECT5114101/08/2021
Building Lifecycle
All (50)Filed (4)Permit Issued (2)Signed Off (1)Objection (17)Special Inspection (26)
01/12/2023
Signed off — Alteration
Q00449924-I1
03/03/2022
Permit issued — General Construction
Q00449924-I1-GC
02/24/2022
Permit issued — Foundation
Q00449924-S1-GC-CX
01/27/2022
Objection resolved — Resolved
01/27/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Oscar Walters Jr
01/04/2022
Objection resolved — Resolved
01/04/2022
Objection resolved — Resolved
12/01/2021
Filed — Alteration
Underpinning of Masonry Bearing Wall of Existing 1-car Detached Garage
Q00595786-S1
12/01/2021
Objection resolved — Resolved
12/01/2021
Objection resolved — Resolved
12/01/2021
Objection resolved — Resolved
12/01/2021
Objection resolved — Resolved
12/01/2021
Objection resolved — Resolved
09/30/2021
Objection raised — Scope
09/30/2021
Objection raised — Inspections
09/30/2021
Objection raised — Other
09/30/2021
Objection raised — Structural
09/30/2021
Objection raised — Structural
09/30/2021
Objection raised — Structural
09/30/2021
Objection raised — Structural
09/30/2021
Objection raised — Inspections
09/30/2021
Objection raised — Structural
09/21/2021
Filed — Alteration
Underpinning of Masonry Bearing Wall of Existing 1-car Detached Garage
Q00595786-I1
09/21/2021
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Oscar Walters Jr
09/21/2021
Special inspection requirement — Subgrade Inspections
Oscar Walters Jr
09/21/2021
Special inspection requirement — Final
Oscar Walters Jr
09/21/2021
Special inspection requirement — Footing and Foundation
Oscar Walters Jr
09/21/2021
Special inspection requirement — Concrete - Cast-In-Place
Oscar Walters Jr
09/17/2021
Special inspection requirement — Footing and Foundation
Oscar Walters Jr
09/17/2021
Special inspection requirement — Concrete - Cast-In-Place
Oscar Walters Jr
09/17/2021
Special inspection requirement — Subgrade Inspections
Oscar Walters Jr
09/17/2021
Special inspection requirement — Final
Oscar Walters Jr
09/17/2021
Special inspection requirement — Underpinning
Oscar Walters Jr
09/07/2021
Filed — Alteration
Q00449924-S1
09/07/2021
Special inspection requirement — Lighting controls
Oscar Walters Jr
08/11/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Oscar Walters Jr
08/11/2021
Special inspection requirement — Concrete - Cast-In-Place
Oscar Walters Jr
08/11/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Oscar Walters Jr
08/11/2021
Special inspection requirement — Masonry
Oscar Walters Jr
08/11/2021
Special inspection requirement — Structural Cold-Formed Steel
Oscar Walters Jr
08/11/2021
Special inspection requirement — Structural Steel - Details
Oscar Walters Jr
08/11/2021
Special inspection requirement — Subgrade Inspections
Oscar Walters Jr
08/11/2021
Special inspection requirement — Underpinning
Oscar Walters Jr
08/11/2021
Special inspection requirement — Final
Oscar Walters Jr
08/11/2021
Special inspection requirement — Footing and Foundation
Oscar Walters Jr
01/08/2021
Filed — Alteration
Q00449924-I1
01/08/2021
Special inspection requirement — Maintenance information
michael almon
01/07/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
michael almon
01/07/2021
Special inspection requirement — Final
michael almon
01/07/2021
Special inspection requirement — Fire-Resistance Rated Construction
michael almon
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offKJH BUILDING & DEV CORP03/03/2022
DOB NOWFoundationSigned-offKJH BUILDING & DEV CORP02/24/2022
1 project · most recent 12/01/2021
FiledStatusContractorScope
12/01/2021——2 scope_items
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
01/27/2022Structural Stability – Alterations of existing buildingsOscar Walters Jrspecial
09/21/2021Excavations - Sheeting, Shoring, and BracingOscar Walters Jrspecial
09/21/2021Subgrade InspectionsOscar Walters Jrspecial
09/21/2021FinalOscar Walters Jrprogress
09/21/2021Footing and FoundationOscar Walters Jrprogress
09/21/2021Concrete - Cast-In-PlaceOscar Walters Jrspecial
09/17/2021Footing and FoundationOscar Walters Jrprogress
09/17/2021Concrete - Cast-In-PlaceOscar Walters Jrspecial
09/17/2021Subgrade InspectionsOscar Walters Jrspecial
09/17/2021FinalOscar Walters Jrprogress
09/17/2021UnderpinningOscar Walters Jrspecial
09/07/2021Lighting controlsOscar Walters Jrenergy_progress
08/11/2021Structural Stability – Alterations of existing buildingsOscar Walters Jrspecial
08/11/2021Concrete - Cast-In-PlaceOscar Walters Jrspecial
08/11/2021Fire-Resistant Penetrations and JointsOscar Walters Jrspecial
08/11/2021MasonryOscar Walters Jrspecial
08/11/2021Structural Cold-Formed SteelOscar Walters Jrspecial
08/11/2021Structural Steel - DetailsOscar Walters Jrspecial
08/11/2021Subgrade InspectionsOscar Walters Jrspecial
08/11/2021UnderpinningOscar Walters Jrspecial
08/11/2021FinalOscar Walters Jrprogress
08/11/2021Footing and FoundationOscar Walters Jrprogress
01/08/2021Maintenance informationmichael almonenergy_progress
01/07/2021Structural Stability – Alterations of existing buildingsmichael almonspecial
01/07/2021Finalmichael almonprogress
Latest 25 of 26.
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch3
08/27/2026Q00449924-S1Request digital key ↗
08/27/2026Q00595786-S1Request digital key ↗
08/15/2026Q00595786-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
08/27/2026Q00449924-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00449924-S1Open ↗
08/13/2026Q00449924-I1Open ↗
▸Seals & Professional Certifications18
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026Q00595786-I1Open ↗
09/01/2026Q00449924-S1Open ↗
09/01/2026Q00449924-S1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026Q00595786-I1Open ↗
09/01/2026Q00595786-I1Open ↗
09/01/2026Q00595786-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026Q00449924-S1Open ↗
08/27/2026Q00449924-I1Open ↗
08/27/2026Q00595786-S1Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q00449924-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/27/2026Q00449924-S1Open ↗
08/27/2026Q00449924-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00449924-I1Open ↗
▸Other Documents4
▸DOB NOWPlot Diagram2
08/13/2026Q00449924-I1Open ↗
08/13/2026Q00449924-S1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00449924-I1Open ↗
08/13/2026Q00449924-S1Open ↗