Permit Issued — active, not yet Signed-off
Floor 1Restaurant renovation, 1st floorUnder Construction2p · 1 filing · 17 docs
CellarRestaurant renovation, 1st floorUnder Construction4p · 2 filings · 20 docs
Site & exteriorRestaurant renovation, 1st floorUnder Construction1p · 1 filing · 17 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/03/2024$1.3M—Private party → Private party$448/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Self Employee310/12/2026
Yang Engineering405/19/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SD Design Studio803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Tri State Plumbing & HeatingPlumbing407/08/2026
Mercury Building AssociatesGeneral Contractor210/09/2026
A.C. Morgan ElectricElectrical103/22/2026
American Standard P&H CororpPlumbing109/17/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM Engineering6244210/12/2026
Yang Engineering8376405/19/2025
Building Lifecycle
All (50)Filed (7)Permit Issued (7)Signed Off (2)Inspection (4)Special Inspection (30)
10/12/2026
Filed — Alteration
RENOVATION OF PROPOSED RESTAURANT ON 1ST FLOOR WITH, RELOCATE/REPLACE PLUMBING FIXTURES AND COOKING EQUIPMENTS AS PER PLAN. TO SUPERSEDE DOB JOB#301056513. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01458295-P1
10/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
10/09/2026
Special inspection requirement — Mechanical Systems
NARESH MAHANGU
10/09/2026
Special inspection requirement — Tenant Protection Plan Compliance
NARESH MAHANGU
10/09/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
10/09/2026
Special inspection requirement — Final
Manuel Ramirez Lachica
10/09/2026
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
10/09/2026
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
10/09/2026
Special inspection requirement — Interior lighting power
NARESH MAHANGU
10/09/2026
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
10/09/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
10/08/2026
Permit issued — General Construction
B01458295-I1-MS
10/08/2026
Permit issued — Mechanical Systems
B01458295-I1-GC
09/16/2026
Permit issued — Plumbing
B01458295-S1-PL
09/14/2026
Filed — Alteration
RENOVATION OF PROPOSED RESTAURANT ON 1ST FLOOR WITH, RELOCATE/REPLACE PLUMBING FIXTURES AND COOKING EQUIPMENTS AS PER PLAN. TO SUPERSEDE DOB JOB#301056513. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01458295-S1
09/14/2026
Special inspection requirement — Energy Code Compliance Inspections
Manuel Ramirez Lachica
09/11/2026
Filed — Alteration
RENOVATION OF PROPOSED RESTAURANT ON 1ST FLOOR WITH, RELOCATE/REPLACE PLUMBING FIXTURES AND COOKING EQUIPMENTS AS PER PLAN. TO SUPERSEDE DOB JOB#301056513. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01458295-I1
09/10/2026
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
09/10/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
09/10/2026
Special inspection requirement — Final
Manuel Ramirez Lachica
09/10/2026
Special inspection requirement — Tenant Protection Plan Compliance
NARESH MAHANGU
09/10/2026
Special inspection requirement — Mechanical Systems
NARESH MAHANGU
09/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
09/10/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
09/10/2026
Special inspection requirement — Interior lighting power
NARESH MAHANGU
09/10/2026
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
09/10/2026
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
09/11/2025
Signed off — Alteration
REMOVE EXISTING (1) BOILERS AND INSTALL NEW (2) GAS BOILERS AT CELLAR. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B01021893-S1
09/11/2025
Signed off — Alteration
REMOVE EXISTING (1) BOILERS AND INSTALL NEW (2) GAS BOILERS AT CELLAR. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B01021893-I1
06/03/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/03/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/29/2025
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
05/29/2025
Special inspection requirement — Tenant Protection Plan Compliance
Jian Yang
05/29/2025
Special inspection requirement — Energy Code Compliance Inspections
Jian Yang
05/29/2025
Special inspection requirement — HVAC-R and service water heating equipment
Jian Yang
05/29/2025
Special inspection requirement — HVAC-R and service water heating system controls
Jian Yang
05/29/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Jian Yang
05/29/2025
Special inspection requirement — Maintenance information
Jian Yang
05/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jian Yang
05/20/2025
Special inspection requirement — HVAC-R and service water heating system controls
Jian Yang
05/20/2025
Special inspection requirement — HVAC-R and service water heating equipment
Jian Yang
05/19/2025
Filed — Alteration
REMOVE EXISTING (1) BOILERS AND INSTALL NEW (2) GAS BOILERS AT CELLAR. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B01021893-P2
05/14/2025
Filed — Alteration
REMOVE EXISTING (1) BOILERS AND INSTALL NEW (2) GAS BOILERS AT CELLAR. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B01021893-P1
05/08/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/21/2025
Permit issued — Boiler Equipment
B01021893-I1-BE
04/21/2025
Permit issued — Plumbing
B01021893-S1-PL
04/17/2024
Permit issued — Plumbing
B01021893-S1-PL
04/17/2024
Permit issued — Boiler Equipment
B01021893-I1-BE
04/04/2024
Filed — Alteration
REMOVE EXISTING (1) BOILERS AND INSTALL NEW (2) GAS BOILERS AT CELLAR. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B01021893-S1
04/04/2024
Filed — Alteration
REMOVE EXISTING (1) BOILERS AND INSTALL NEW (2) GAS BOILERS AT CELLAR. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B01021893-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMercury Building Associates10/08/2026
DOB NOWMechanical SystemsPermit IssuedMercury Building Associates10/08/2026
DOB NOWPlumbingPermit IssuedAmerican Standard P&H Cororp09/16/2026
DOB NOWBoiler EquipmentSigned-offDW Plumbing04/21/2025
DOB NOWPlumbingSigned-offDW Plumbing04/21/2025
DOB NOWPlumbingSigned-offDW Plumbing04/17/2024
DOB NOWBoiler EquipmentSigned-offDW Plumbing04/17/2024
BISOTISSUEDNic Design Management07/05/2017
BISFPISSUEDMaster Fire Systems08/07/2000
1 project · most recent 10/12/2026
Air Conditioning Systems Refrigeration Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/12/2026Permit IssuedMercury Building AssociatesAir Conditioning Systems, Refrigeration Systems, Ventilation Systems
Cooling
Gree ×4
Refrigeration
Embraco UFI12HBX1 5,300 BTU · Refrigeration Unit ×4
Ventilation
N/A ×1
1 project · most recent 10/12/2026
Gas Water/Sanitary
FiledStatusContractorScope
10/12/2026Permit IssuedAmerican Standard P&HGas, Water/Sanitary
3 projects · most recent 09/15/2026
General Wiring
FiledStatusContractorScope
09/15/2026Permit IssuedLauri ElectricalGeneral Wiring
10/22/2024CompleteA.C. Morgan ElectricGeneral Wiring
05/08/2024CompleteEric & NG Electrical4 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
06/03/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/03/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/29/2025Pass-Final Boiler Equipment InspectionPassView ↗
05/08/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 35
DateRequirementInspectorRole
10/09/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
10/09/2026Mechanical SystemsNARESH MAHANGUspecial
10/09/2026Tenant Protection Plan ComplianceNARESH MAHANGUspecial
10/09/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
10/09/2026FinalManuel Ramirez Lachicaprogress
10/09/2026Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
10/09/2026HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
10/09/2026Interior lighting powerNARESH MAHANGUenergy_progress
10/09/2026HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
10/09/2026HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
09/14/2026Energy Code Compliance InspectionsManuel Ramirez Lachicaprogress
09/10/2026Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
09/10/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
09/10/2026FinalManuel Ramirez Lachicaprogress
09/10/2026Tenant Protection Plan ComplianceNARESH MAHANGUspecial
09/10/2026Mechanical SystemsNARESH MAHANGUspecial
09/10/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
09/10/2026HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
09/10/2026Interior lighting powerNARESH MAHANGUenergy_progress
09/10/2026HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
09/10/2026HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
05/29/2025Tenant Protection Plan ComplianceJian Yangspecial
05/29/2025Energy Code Compliance InspectionsJian Yangprogress
05/29/2025HVAC-R and service water heating equipmentJian Yangenergy_progress
05/29/2025HVAC-R and service water heating system controlsJian Yangenergy_progress
Latest 25 of 35.
▾Documents — 57 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/23/2026B01458295-S1Request digital key ↗
09/23/2026B01458295-I1Request digital key ↗
08/25/2026B01021893-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION4
10/17/2023321612475Open ↗
09/12/2023321612475Open ↗
09/11/2023321612475Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION1
07/10/2017321612475Open ↗
▸Seals & Professional Certifications24
▸DOB NOWProgress Inspector Seal & Signature10
10/14/2026B01458295-I1Open ↗
10/14/2026B01458295-I1Open ↗
10/13/2026B01458295-P1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
10/13/2026B01458295-P1Open ↗
09/18/2026B01458295-I1Open ↗
09/18/2026B01458295-S1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
10/14/2026B01458295-I1Open ↗
10/13/2026B01458295-P1Open ↗
09/23/2026B01021893-I1Open ↗
Showing 3 of 4 on file for this type
▸BISProfessional and Owner Certification (POC3)1
07/10/2017321612475Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/10/2017321612475Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
07/10/2017321612475Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
07/10/2017321612475Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
10/13/2026B01458295-P1Open ↗
09/18/2026B01458295-I1Open ↗
09/18/2026B01458295-S1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/10/2017321612475Open ↗
▸Energy Compliance5
▸BISINTERIOR LIGHTING POWER1
10/27/2023321612475Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
10/27/2023321612475Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
10/27/2023321612475Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
10/27/2023321612475Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
07/10/2017321612475Open ↗
▸Inspections & Test Reports2
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
10/27/2023321612475Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
10/27/2023321612475Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/30/2023321612475Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
07/10/2017321612475Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
10/27/2023321612475Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
10/17/2023321612475Open ↗
▸BISEFILING COVER SHEET1
07/17/2017321612475Open ↗
▸Other Documents1
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
10/30/2023321612475Open ↗