2Units
4 Open Violations 2 unresolved · 2 paperwork only ▸FDNY Report ↗
Two family brick · 1,600 sf lot · 1.78 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
CellarUnder Construction1p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/22/2025$890K—Private party → Private party$312/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOHAMMAD AHEAD, PE112/27/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LIGHT HOUSE103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LV CONTRACTING SOLUTIONSGeneral Contractor110/02/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NORMAN C. LOK818112/27/2025
Building Lifecycle
All (21)Filed (1)Permit Issued (1)Violation (8)Objection (8)Special Inspection (3)
10/01/2026
Permit issued — General Construction
B01334221-I1-GC
01/15/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/14/2026
Objection raised — Mechanical
01/14/2026
Objection raised — Cost
01/14/2026
Objection raised — Scope
01/14/2026
Objection raised — Other
12/27/2025
Filed — Alteration
1. Remove partitions creating rooms at cellar. 2. Install New fire rated boiler room enclosure. 3.Filing to correct ECB Violations39162367L,39162368N,39162370M,39162369P. 4. Plumbing addressed under LAA # B01333127
B01334221-I1
12/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NORMAN LOK
12/15/2025
Special inspection requirement — Final
ADITYA DESAI
12/15/2025
Special inspection requirement — Fire-Resistance Rated Construction
MOHAMMAD AHEAD
10/03/2025
Violation issued (ECB, closed)
Unknown
10/03/2025
Violation issued (ECB, closed)
Construction
10/03/2025
Violation issued (ECB, closed)
Construction
10/03/2025
Violation issued (ECB, closed)
Construction
10/02/2025
Violation issued (ECB, open)
Unknown
10/02/2025
Violation issued (ECB, open)
Construction
10/02/2025
Violation issued (ECB, open)
Construction
10/02/2025
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedLV CONTRACTING SOLUTIONS10/01/2026
1 project · most recent 03/19/2026
FiledStatusContractorScope
03/19/2026CompleteAGIR ELEC'L LTD. D/B/A—
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
12/15/2025Fire-Resistant Penetrations and JointsNORMAN LOKspecial
12/15/2025FinalADITYA DESAIprogress
12/15/2025Fire-Resistance Rated ConstructionMOHAMMAD AHEADprogress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026B01334221-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026B01334221-I1Open ↗
08/25/2026B01334221-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/19/2026B01334221-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B01334221-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026B01334221-I1Open ↗