← Back
Walk-up cooperative
23 BETHUNE STREET
MANHATTAN · BIN 1084968
💬 Discuss this project
1939Year Built
4Stories
C6Building Class
R6Zoning
6,924 sfGross Floor Area
8Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Walk-up cooperative · Owner of record: 21-23 BETHUNE ST TNTS · 3,401 sf lot · 2.04 FAR built · Flood zone X500
Locations of Work
Mechanical
Floor 15p · 1 filing · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CFA MANAGEMENT2107/08/2026
21-23 BETHUNE ST TENANTS CORP303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EDIFICE DRAFTING AND SERVICES101/06/2025
MURRAY ENGINEERING PC405/09/2022
ADAL ENGINEERING PLLC101/22/2021
HUNT ARCHITECTURE101/19/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A+ EXPEDITING1003/21/2026
DOMANI CONSULTING103/21/2026
4444 PPPP CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TOP HAT SOLUTIONS CORPGeneral Contractor603/21/2026
SHAI SHICLYElectrical503/21/2026
G&K CONSTRUCTION INCGeneral Contractor303/21/2026
VECTRA CONSTRUCTION CORPGeneral Contractor204/09/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AM ENGINEERING SERVICES P7975101/06/2025
MURRAY ENGINEERING PC1434105/09/2022
DELTA TESTING LABS687411/05/2021
Building Lifecycle
All (61)Filed (7)Permit Issued (6)Signed Off (3)Violation (3)Objection (12)Special Inspection (30)
04/29/2026
Violation issued (HPD, open)
A
01/07/2026
Signed off — Alteration
No change to building use, egress and occupancy under this application. Alteration type 2, minor interior renovation and HVAC work
M01157502-I1
06/04/2025
Violation issued (HPD, open)
A
01/14/2025
Permit issued — Mechanical Systems
M01157502-I1-GC
01/14/2025
Permit issued — Mechanical Systems
M01157502-I1-MS
01/06/2025
Filed — Alteration
No change to building use, egress and occupancy under this application. Alteration type 2, minor interior renovation and HVAC work
M01157502-I1
12/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Albert Munoz
12/18/2024
Special inspection requirement — Final
Albert Munoz
12/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Albert Munoz
12/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
Albert Munoz
12/18/2024
Special inspection requirement — HVAC-R and service water heating system controls
Albert Munoz
12/18/2024
Special inspection requirement — HVAC-R and service water heating equipment
Albert Munoz
12/18/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Albert Munoz
12/18/2024
Special inspection requirement — Lighting in dwelling units
Albert Munoz
12/18/2024
Special inspection requirement — Lighting controls
Albert Munoz
12/18/2024
Special inspection requirement — Maintenance information
Albert Munoz
12/18/2024
Special inspection requirement — Mechanical Systems
Albert Munoz
07/26/2024
Signed off — Alteration
Plumbing work type in conjunction with Alt 2 job 140983577 to include replacement and relocation of existing fixtures
M00437666-I1
09/12/2023
Signed off — Alteration
M00691909-I1
02/02/2023
Permit issued — General Construction
M00691909-I1-GC
10/11/2022
Permit issued — General Construction
M00691909-I1-GC
05/09/2022
Filed — Alteration
M00691909-I1
11/23/2021
Special inspection requirement — Structural Steel - Details
11/23/2021
Special inspection requirement — Structural Steel - High Strength Bolting
RICHARD GREENWALD
11/23/2021
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
RICHARD GREENWALD
11/23/2021
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
RICHARD GREENWALD
11/23/2021
Special inspection requirement — Concrete - Cast-In-Place
RICHARD GREENWALD
11/23/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
RICHARD GREENWALD
11/23/2021
Special inspection requirement — Footing and Foundation
11/23/2021
Special inspection requirement — Final
11/23/2021
Special inspection requirement — Structural Steel - Welding
RICHARD GREENWALD
11/05/2021
Filed — Alteration
Structural in conjunction with Alt 140983577 to create a new opening in the rear facade with window replacement, new concrete 27 lf retaining wall, footing & stair, Full interior gut, as per the plans filed herewith
M00459731-P3
10/25/2021
Special inspection requirement — Structural Steel - Details
10/18/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
RICHARD GREENWALD
10/18/2021
Special inspection requirement — Structural Steel - High Strength Bolting
RICHARD GREENWALD
10/18/2021
Special inspection requirement — Structural Steel - Welding
RICHARD GREENWALD
10/18/2021
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
RICHARD GREENWALD
10/18/2021
Special inspection requirement — Final
10/18/2021
Special inspection requirement — Footing and Foundation
10/18/2021
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
RICHARD GREENWALD
10/18/2021
Special inspection requirement — Concrete - Cast-In-Place
RICHARD GREENWALD
05/27/2021
Filed — Alteration
Structural in conjunction with Alt 140983577 to create a new opening in the rear facade with window replacement, new concrete 27 lf retaining wall, footing & stair, Full interior gut, as per the plans filed herewith
M00459731-P1
05/20/2021
Special inspection requirement — Structural Steel - Welding
RICHARD GREENWALD
03/10/2021
Filed — Alteration
Structural in conjunction with Alt 140983577 to create a new opening in the rear facade with window replacement, new concrete 27 lf retaining wall, footing & stair, Full interior gut, as per the plans filed herewith
M00459731-I1
03/10/2021
Permit issued — Plumbing
M00437666-I1-PL
02/26/2021
Permit issued — Mechanical Systems
M00440239-I1-MS
02/12/2021
Objection raised — Other
02/12/2021
Objection resolved — Addressed
02/12/2021
Objection raised — Other
02/12/2021
Objection resolved — Addressed
01/26/2021
Objection raised — Other
01/26/2021
Objection resolved — Addressed
01/26/2021
Objection raised — Other
01/26/2021
Objection resolved — Addressed
01/26/2021
Objection raised — Other
01/26/2021
Objection resolved — Addressed
01/26/2021
Objection raised — Other
01/26/2021
Objection resolved — Addressed
01/22/2021
Filed — Alteration
Mechanical work type in conjunction with job # 140983577-new split unit with duct work & air handler
M00440239-I1
01/19/2021
Filed — Alteration
Plumbing work type in conjunction with Alt 2 job 140983577 to include replacement and relocation of existing fixtures
M00437666-I1
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offVECTRA CONSTRUCTION CORP01/14/2025
DOB NOWMechanical SystemsSigned-offVECTRA CONSTRUCTION CORP01/14/2025
DOB NOWGeneral ConstructionSigned-offTOP HAT SOLUTIONS CORP02/02/2023
DOB NOWGeneral ConstructionSigned-offTOP HAT SOLUTIONS CORP10/11/2022
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.03/10/2021
DOB NOWMechanical SystemsPermit IssuedG&K CONSTRUCTION INC02/26/2021
BISOTISSUEDG&K CONSTRUCTION INC09/06/2021
BISOTISSUEDG&K CONSTRUCTION INC01/25/2021
1 job · most recent 01/22/2021
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
01/22/2021Permit IssuedG&K CONSTRUCTION INCAir Conditioning Systems
Cooling
Daikin RXTQ36TAVJU 3 tons · Vrf Outdoor ×1
Heating
Daikin RXTQ36TAVJU 3 tons · Vrf Outdoor ×1
2 jobs · most recent 05/14/2025
General Wiring
FiledStatusContractorScope
05/14/2025CompleteCITY ELECTRIC LLCGeneral Wiring
11/18/2021CompleteKRIS ELECTRICAL SOLUTIONSGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 48
DateRequirementInspectorRole
12/18/2024Fire-Resistant Penetrations and JointsAlbert Munozspecial
12/18/2024FinalAlbert Munozprogress
12/18/2024Energy Code Compliance InspectionsAlbert Munozprogress
12/18/2024Fire-Resistance Rated ConstructionAlbert Munozprogress
12/18/2024HVAC-R and service water heating system controlsAlbert Munozenergy_progress
12/18/2024HVAC-R and service water heating equipmentAlbert Munozenergy_progress
12/18/2024HVAC-R and service water piping design and insulationAlbert Munozenergy_progress
12/18/2024Lighting in dwelling unitsAlbert Munozenergy_progress
12/18/2024Lighting controlsAlbert Munozenergy_progress
12/18/2024Maintenance informationAlbert Munozenergy_progress
12/18/2024Mechanical SystemsAlbert Munozspecial
11/23/2021Structural Steel - Details—special
11/23/2021Structural Steel - High Strength BoltingRICHARD GREENWALDspecial
11/23/2021Excavations - Sheeting, Shoring, and BracingRICHARD GREENWALDspecial
11/23/2021Subsurface Conditions – Fill Placement & In-Place DensityRICHARD GREENWALDspecial
11/23/2021Concrete - Cast-In-PlaceRICHARD GREENWALDspecial
11/23/2021Structural Stability – Alterations of existing buildingsRICHARD GREENWALDspecial
11/23/2021Footing and Foundation—progress
11/23/2021Final—progress
11/23/2021Structural Steel - WeldingRICHARD GREENWALDspecial
10/25/2021Structural Steel - Details—special
10/18/2021Structural Stability – Alterations of existing buildingsRICHARD GREENWALDspecial
10/18/2021Structural Steel - High Strength BoltingRICHARD GREENWALDspecial
10/18/2021Structural Steel - WeldingRICHARD GREENWALDspecial
10/18/2021Subsurface Conditions – Fill Placement & In-Place DensityRICHARD GREENWALDspecial
Latest 25 of 48.
▾Documents — 96 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch - Foundation3
09/04/2026M00459731-P1Request digital key ↗
09/04/2026M00459731-I1Request digital key ↗
09/04/2026M00459731-P3Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction3
09/04/2026M00459731-P3Request digital key ↗
09/04/2026M00459731-I1Request digital key ↗
09/04/2026M00459731-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural3
09/04/2026M00459731-P1Request digital key ↗
09/04/2026M00459731-I1Request digital key ↗
09/04/2026M00459731-P3Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems2
08/15/2026M00440239-I1Request digital key ↗
08/15/2026M00440239-P1Request digital key ↗
▸DOB NOWPlans/Sketch2
09/02/2026M00691909-I1Request digital key ↗
08/25/2026M01157502-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/04/2026M00437666-I1Request digital key ↗
▸Applications & Permits10
▸DOB NOWLPC Approval/Permit8
09/04/2026M00437666-I1Open ↗
09/04/2026M00459731-P1Open ↗
09/04/2026M00459731-I1Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION1
01/25/2021140983577Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
07/05/2019123823247Open ↗
▸Seals & Professional Certifications38
▸DOB NOWProgress Inspector Seal & Signature14
08/28/2026M00440239-I1Open ↗
08/28/2026M00440239-I1Open ↗
08/26/2026M00440239-P1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
08/28/2026M00459731-I1Open ↗
08/28/2026M00459731-I1Open ↗
08/28/2026M00440239-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/04/2026M00437666-I1Open ↗
09/04/2026M00440239-I1Open ↗
09/04/2026M00440239-P1Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/05/2019123823247Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
12/03/2020140983577Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/05/2019123823247Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
07/05/2019123823247Open ↗
▸Safety & Tenant Protection5
▸DOB NOWTenant Protection Plan3
09/04/2026M00437666-I1Open ↗
08/13/2026M00440239-P1Open ↗
08/13/2026M00440239-I1Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
01/25/2021140983577Open ↗
▸BISTenant Protection Plan and Notes1
07/05/2019123823247Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/04/2026M00437666-I1Open ↗
09/04/2026M00440239-P1Open ↗
09/04/2026M00459731-I1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
12/03/2020140983577Open ↗
07/05/2019123823247Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
01/18/2022140983577Open ↗
01/25/2021140983577Open ↗
12/03/2020140983577Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
01/18/2022140983577Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
07/05/2019123823247Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
01/18/2022140983577Open ↗
01/25/2021140983577Open ↗
12/03/2020140983577Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLANDMARKS APPROVAL2
12/03/2020140983577Open ↗
06/28/2019123823247Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
01/19/2022140983577Open ↗
▸BISLANDMARKS SIGNOFF1
01/19/2022140983577Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT3
01/18/2022140983577Open ↗
12/03/2020140983577Open ↗
07/05/2019123823247Open ↗
▸BISHIC LICENSE OR AFFIDAVIT1
01/25/2021140983577Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION1
12/13/2020140983577Open ↗
▸BISEFILING COVER SHEET1
07/05/2019123823247Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
12/03/2020140983577Open ↗