← Back
Five to six families
231 STANHOPE STREET
BROOKLYN · BIN 3074216
💬 Discuss this project
1931Year Built
3Stories
C2Building Class
R6Zoning
4,875 sfGross Floor Area
6Units
Rent Stabilized5 Open Violations 4 unresolved · 1 paperwork only ▸FDNY Report ↗
Five to six families · Owner of record: 231 STANHOPE 2016 LLC · 2,500 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Floor 22p · 1 filing · 20 docs
Floor 13p · 1 filing · 2 docs
Cellar6p · 2 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BILLY ENTERPRISES507/08/2026
231 STANHOPE 2016 LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/09/2017$1.5M—CAEDVA MANAGEMENT CORP → 231 STANHOPE 2016 LLC$306/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HAIDER ENGINEERING, P.E.103/21/2026
YOUBER DESIGN1003/21/2026
HAIDER ENGINEERING P E103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYC BEST REMODELING INCGeneral Contractor303/21/2026
BILLY ENTERPRISES INCGeneral Contractor207/08/2026
FALCO ELEC'L SERVICES INCElectrical103/22/2026
HOD PIPING & HEATING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SUSTAINABLE DESIGN ENGINE1404210/30/2024
Building Lifecycle
All (115)Filed (9)Permit Issued (4)Signed Off (2)Violation (46)Inspection (3)Objection (38)Special Inspection (13)
07/29/2026
Filed — Alteration
plumbing in cellar for new powder room
B01413879-I1
07/28/2026
Objection resolved — Resolved
07/28/2026
Objection resolved — Resolved
07/28/2026
Objection resolved — Resolved
07/28/2026
Objection resolved — Resolved
07/28/2026
Objection resolved — Resolved
07/22/2026
Objection raised — Other
07/22/2026
Objection raised — Cost
07/22/2026
Objection raised — Other
07/22/2026
Objection raised — Other
07/22/2026
Objection raised — Other
07/08/2026
Filed — Alteration
create accessory use in cellar (non living) for existing first floor apartment
B01413862-I1
06/30/2026
Special inspection requirement — Tenant Protection Plan Compliance
jon libasci
06/30/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/08/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
jon libasci
06/08/2026
Special inspection requirement — Interior lighting power
jon libasci
03/04/2025
Signed off — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 2L ON THE 2ND FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, NEW FLOORING, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B01067902-I1
02/25/2025
Signed off — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 2L ON THE 2ND FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, NEW FLOORING, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B01067902-S1
01/17/2025
Filed — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 2L ON THE 2ND FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, NEW FLOORING, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B01067902-P3
01/13/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/13/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/06/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/20/2024
Objection resolved — Addressed
11/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kenny Mak
11/19/2024
Special inspection requirement — Energy Code Compliance Inspections
Kenny Mak
11/19/2024
Special inspection requirement — Final
Kayan Tse
11/19/2024
Special inspection requirement — Lighting in dwelling units
Kenny Mak
11/12/2024
Objection raised — Other
10/30/2024
Filed — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 2L ON THE 2ND FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, NEW FLOORING, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B01067902-P1
10/30/2024
Filed — Alteration
GENERAL CONSTRUCTION TO RENOVATE APT 2L ON THE 2ND FLOOR. WORK WILL INCLUDE NEW PARTITIONS & FINISHES, NEW FLOORING, AND NEW PLUMBING FIXTURES. NO CHANGE IN USE, EGRESS, OR OCCUPANCY UNDER THIS FILING.
B01067902-P2
10/29/2024
Special inspection requirement — Lighting in dwelling units
Kenny Mak
10/29/2024
Special inspection requirement — Final
Kayan Tse
10/29/2024
Special inspection requirement — Energy Code Compliance Inspections
Kenny Mak
10/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kenny Mak
10/22/2024
Permit issued — Plumbing
B01067902-S1-PL
10/04/2024
Permit issued — General Construction
B01067902-I1-GC
10/02/2024
Objection raised — Scope
10/02/2024
Objection resolved — Addressed
10/02/2024
Objection raised — Other
10/02/2024
Objection resolved — Addressed
10/02/2024
Objection raised — Scope
10/02/2024
Objection resolved — Addressed
09/26/2024
Filed — Alteration
B01115947-I1
09/26/2024
Special inspection requirement — Tenant Protection Plan Compliance
08/06/2024
Objection resolved — Addressed
07/31/2024
Objection resolved — Addressed
07/31/2024
Objection resolved — Addressed
07/30/2024
Objection raised — Other
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/26/2024
Objection resolved — Addressed
07/26/2024
Objection resolved — Addressed
07/26/2024
Objection resolved — Addressed
07/25/2024
Objection raised — Other
07/25/2024
Objection raised — Other
07/25/2024
Objection raised — Other
07/12/2024
Objection raised — Other
07/11/2024
Objection raised — Other
Latest 60 of 115 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offHOD PIPING & HEATING CORP10/22/2024
DOB NOWGeneral ConstructionSigned-offNYC BEST REMODELING INC10/04/2024
DOB NOWSidewalk ShedPermit IssuedBILLY ENTERPRISES INC01/15/2019
DOB NOWSidewalk ShedPermit IssuedBILLY ENTERPRISES INC10/30/2018
BISOTISSUEDSTEEL TONE CONSTRUCTION11/29/2017
BISPLISSUEDTOP PLUMBING GROUP,INC11/29/2017
BISOTISSUEDMD. ASHRAF ALI11/28/2011
1 project · most recent 07/29/2026
Water/Sanitary
FiledStatusContractorScope
07/29/2026——Water/Sanitary
3 projects · most recent 05/26/2026
General Wiring
FiledStatusContractorScope
05/26/2026Permit IssuedFALCO ELEC'L SERVICES INCGeneral Wiring
10/29/2018Permit IssuedRICHARD NEU—
03/07/2018CompleteB.P. ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
01/13/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/13/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/06/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
06/30/2026Tenant Protection Plan Compliancejon libascispecial
06/30/2026Tenant Protection Plan Compliance—special
06/08/2026Fenestration and door U-factor and product ratingsjon libascienergy_progress
06/08/2026Interior lighting powerjon libascienergy_progress
11/19/2024Fire-Resistant Penetrations and JointsKenny Makspecial
11/19/2024Energy Code Compliance InspectionsKenny Makprogress
11/19/2024FinalKayan Tseprogress
11/19/2024Lighting in dwelling unitsKenny Makenergy_progress
10/29/2024Lighting in dwelling unitsKenny Makenergy_progress
10/29/2024FinalKayan Tseprogress
10/29/2024Energy Code Compliance InspectionsKenny Makprogress
10/29/2024Fire-Resistant Penetrations and JointsKenny Makspecial
09/26/2024Tenant Protection Plan Compliance—special
▾Documents — 71 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/02/2026B00084867-I1Request digital key ↗
08/23/2026B01067902-S1Request digital key ↗
08/23/2026B01067902-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION5
05/11/2018321674434Open ↗
05/02/2018321674434Open ↗
12/20/2017321674434Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
11/30/2017321674434Open ↗
11/30/2017321674434Open ↗
11/30/2017321674434Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION4
05/10/2018321674434Open ↗
04/24/2018321674434Open ↗
02/07/2018321674434Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/02/2026B00084867-I1Open ↗
08/23/2026B01067902-S1Open ↗
08/23/2026B01067902-P3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B01067902-P1Open ↗
09/01/2026B01067902-P1Open ↗
09/01/2026B01067902-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B01067902-P1Open ↗
09/01/2026B01413862-I1Open ↗
08/23/2026B01067902-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
11/30/2017321674434Open ↗
11/29/2011320406404Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
11/30/2017321674434Open ↗
11/29/2011320406404Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/30/2017321674434Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
11/29/2011320406404Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
05/11/2018321674434Open ↗
05/02/2018321674434Open ↗
12/20/2017321674434Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
11/30/2017321674434Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/23/2026B01067902-S1Open ↗
08/23/2026B01067902-P3Open ↗
08/23/2026B01067902-P1Open ↗
Showing 3 of 7 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
11/29/2011320406404Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/30/2017321674434Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/30/2017321674434Open ↗
▸BISTECHNICAL REPORT: ENERGY1
11/29/2011320406404Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
11/29/2011320406404Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/30/2017321674434Open ↗
11/29/2011320406404Open ↗
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION3
01/16/2019321674434Open ↗
04/27/2018321674434Open ↗
02/09/2018321674434Open ↗
▸BISEFILING COVER SHEET2
11/30/2017321674434Open ↗
11/29/2011320406404Open ↗
▸Other Documents1
▸DOB NOWBSA Meeting Minutes/BSA Resolution1
08/13/2026B00084867-I1Open ↗