← Back
Two family brick
2318 VALENTINE AVENUE
BRONX · Fordham Heights · BIN 2013430
💬 Discuss this project
1901Year Built
2Stories
B1Building Class
R7-1Zoning
2,886 sfGross Floor Area
2Units
5 Open Violations ▸
Two family brick · 3,487 sf lot · 0.83 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Filed — no permit issued54p · 2 filings · 11 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/31/2025$1.1M—— → —$381/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOHAMMAD AHEAD, PE107/08/2026
PRAMODRAY SHAH, P.E.112/09/2025
AG ENGINEERING PLLC311/27/2025
VASILIOS ARTEMIOU PE111/26/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
XPDITE GROUP LLC (104)503/21/2026
XPDITE GROUP LLC 104303/21/2026
XPDITE GROUP LLC 105203/21/2026
Building Lifecycle
All (92)Filed (6)Violation (10)Objection (46)Special Inspection (30)
09/17/2026
Objection resolved — Resolved
08/10/2026
Objection raised — Other
07/08/2026
Filed — New Building
Development hub Job by Default; As Project is Eight (8) stories, Per service notice Posted April 16, 2021 such Jobs shall be assigned to the Development Hub Unit - Subject building is a Eight Story Building
X01424193-I1
03/23/2026
Objection resolved — Resolved
03/10/2026
Objection resolved — Resolved
03/10/2026
Objection resolved — Resolved
03/10/2026
Objection resolved — Resolved
03/10/2026
Objection resolved — Resolved
03/10/2026
Objection resolved — Resolved
03/02/2026
Objection raised — Other
03/02/2026
Objection raised — Other
03/02/2026
Objection raised — Other
03/02/2026
Objection raised — Other
03/02/2026
Objection raised — Admin
02/17/2026
Objection resolved — Addressed
02/02/2026
Objection resolved — Addressed
01/31/2026
Objection raised — Zoning
01/09/2026
Objection resolved — Addressed
12/31/2025
Objection raised — Admin
12/31/2025
Objection raised — Other
12/31/2025
Objection resolved — Resolved
12/26/2025
Objection raised — Admin
12/22/2025
Objection raised — Other
12/22/2025
Objection resolved — Addressed
12/15/2025
Objection resolved — Addressed
12/09/2025
Filed — Alteration CO
PLUMBING APPLICATION FILED HEREWITH IN CONJUNCTION TO ALT-CO APPLICATION X01275391-I1
X01275391-S7
12/09/2025
Objection raised — Admin
12/09/2025
Objection raised — Fire_Protection
12/09/2025
Objection resolved — Addressed
12/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
12/08/2025
Special inspection requirement — Structural Wood Frame
12/08/2025
Special inspection requirement — Wood – Prefabricated I-Joists
12/05/2025
Objection raised — Energy
12/05/2025
Objection raised — Energy
11/27/2025
Filed — Alteration CO
PLUMBING APPLICATION FILED HEREWITH IN CONJUNCTION TO ALT-CO APPLICATION X01275391-I1
X01275391-S1
11/26/2025
Filed — Alteration CO
PLUMBING APPLICATION FILED HEREWITH IN CONJUNCTION TO ALT-CO APPLICATION X01275391-I1
X01275391-S3
11/26/2025
Objection resolved — Addressed
11/25/2025
Filed — Alteration CO
PLUMBING APPLICATION FILED HEREWITH IN CONJUNCTION TO ALT-CO APPLICATION X01275391-I1
X01275391-S2
11/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/24/2025
Special inspection requirement — Energy Code Compliance Inspections
11/24/2025
Special inspection requirement — HVAC-R and service water heating system controls
11/24/2025
Special inspection requirement — HVAC-R and service water heating equipment
11/24/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
11/24/2025
Special inspection requirement — Maintenance information
11/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/24/2025
Special inspection requirement — Post-installed Anchors
11/24/2025
Special inspection requirement — Energy Code Compliance Inspections
11/24/2025
Special inspection requirement — Ventilation and air distribution system
11/24/2025
Special inspection requirement — Permanent certificate
11/24/2025
Special inspection requirement — Duct leakage testing, insulation and design
11/24/2025
Special inspection requirement — Maintenance information
11/24/2025
Special inspection requirement — HVAC-R and service water heating equipment
11/24/2025
Special inspection requirement — HVAC-R and service water heating system controls
11/24/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
11/21/2025
Objection resolved — Addressed
10/31/2025
Objection resolved — Addressed
10/29/2025
Special inspection requirement — Final
10/28/2025
Objection resolved — Addressed
10/27/2025
Objection raised — Zoning
Latest 60 of 92 events.
Nothing on file for this building.
1 project · most recent 12/09/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
12/09/2025——Heating and Air Conditioning Systems
Heat / Cool
Daikin 2MXM18AVJU9 18,900 BTU · Split System ×8
3MXS24RMVJU 24,000 BTU · Split System ×2
1 project · most recent 12/09/2025
Sprinkler System
FiledStatusContractorScope
12/09/2025——Sprinkler System
1 project · most recent 12/09/2025
Storm Water/Sanitary
FiledStatusContractorScope
12/09/2025——Storm, Water/Sanitary
1 project · most recent 11/27/2025
General Wiring
FiledStatusContractorScope
11/27/2025Permit IssuedAG POWER ELECTRIC CORPGeneral Wiring
1 project · most recent 12/09/2025
Wood
FiledStatusContractorScope
12/09/2025——Wood
▾Special Inspection Requirements (DOB NOW) — 37
DateRequirementInspectorRole
12/08/2025Structural Stability – Alterations of existing buildings—special
12/08/2025Structural Wood Frame—progress
12/08/2025Wood – Prefabricated I-Joists—special
11/24/2025Fire-Resistant Penetrations and Joints—special
11/24/2025Energy Code Compliance Inspections—progress
11/24/2025HVAC-R and service water heating system controls—energy_progress
11/24/2025HVAC-R and service water heating equipment—energy_progress
11/24/2025HVAC-R and service water piping design and insulation—energy_progress
11/24/2025Maintenance information—energy_progress
11/24/2025Fire-Resistant Penetrations and Joints—special
11/24/2025Fire-Resistant Penetrations and Joints—special
11/24/2025Post-installed Anchors—special
11/24/2025Energy Code Compliance Inspections—progress
11/24/2025Ventilation and air distribution system—energy_progress
11/24/2025Permanent certificate—energy_progress
11/24/2025Duct leakage testing, insulation and design—energy_progress
11/24/2025Maintenance information—energy_progress
11/24/2025HVAC-R and service water heating equipment—energy_progress
11/24/2025HVAC-R and service water heating system controls—energy_progress
11/24/2025HVAC-R and service water piping design and insulation—energy_progress
10/29/2025Final—progress
09/22/2025Sprinkler Systems—special
09/22/2025Mechanical Systems—special
09/22/2025Final—progress
09/09/2025Metering—energy_progress
Latest 25 of 37.
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026X01275391-I1Request digital key ↗
08/15/2026X01424193-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/17/2026X01275391-I1Open ↗
08/15/2026X01424193-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026X01424193-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026X01275391-I1Open ↗
08/16/2026X01424193-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/17/2026X01275391-I1Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification2
08/17/2026X01275391-I1Open ↗
08/15/2026X01424193-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026X01424193-I1Open ↗