| Owner | Filings | Most Recent |
|---|---|---|
| Belnord Partners | 804 | 07/08/2026 |
| 169 CH9 Owner | 210 | 08/26/2026 |
| Extell Development | 194 | 07/08/2026 |
| Westbrook Properties | 74 | 10/13/2026 |
| Thal Properties | 9 | 09/30/2026 |
| CPR Extell 99 West Side L P | 9 | 03/21/2026 |
| DW AW Belnord Owners | 7 | 03/21/2026 |
| Blockbuster Entertainment | 4 | 03/21/2026 |
| Charter | 1 | 03/22/2026 |
| Avacon Builders Group | 1 | 03/22/2026 |
| 150 Price Parkawy | 1 | 03/21/2026 |
| Representative | Filings | Most Recent |
|---|---|---|
| DVA Advisors | 78 | 03/21/2026 |
| William Vitacco Associates | 41 | 03/21/2026 |
| New York Design Architects | 10 | 03/21/2026 |
| Municipal Building Consultants | 13 | 03/21/2026 |
| National Maintenance | 4 | 03/21/2026 |
| Expedition NYC | 7 | 03/21/2026 |
| NYC Department of Housing Preservation and Development | 4 | 03/21/2026 |
| Rigid Structural Design | 1 | 03/21/2026 |
| Code | 6 | 03/21/2026 |
| Beam Living | 4 | 03/21/2026 |
| EA Design Group | 10 | 03/21/2026 |
| Louis Striar | 4 | 03/21/2026 |
| DJ Associates Architect | 4 | 03/21/2026 |
| Jenny Flores Expediting | 2 | 03/21/2026 |
| Kossar Garry Architects | 2 | 03/21/2026 |
| Vmarchdesign | 3 | 03/21/2026 |
| William Vittaco Associates | 3 | 03/21/2026 |
| Nyccode | 4 | 03/21/2026 |
| Clarke Construction Consultants | 1 | 03/21/2026 |
| City Expediting | 2 | 03/21/2026 |
| Lois Rosenberg Consultants | 2 | 03/21/2026 |
| Zenesis Group | 1 | 03/21/2026 |
| Patuxent Engineering | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Building Code Partners | General Contractor | 70 | 08/30/2026 |
| Cain Real Estate | General Contractor | 47 | 07/08/2026 |
| CBB Plumbing | Plumbing | 16 | 07/08/2026 |
| Orbit Plumbing & Heating | Plumbing | 14 | 07/08/2026 |
| A & M Warshaw Plumbing & Heating | Plumbing | 10 | 07/08/2026 |
| Orchid Construction | General Contractor | 7 | 07/08/2026 |
| Canido Basonas Construction Service | General Contractor | 4 | 04/09/2026 |
| Crafted Interiors Design | General Contractor | 4 | 07/08/2026 |
| Proto P & H Services | Plumbing | 3 | 07/08/2026 |
| Vlashava Electric Contracting | Electrical | 3 | 03/22/2026 |
| Quality Control Mechanical | General Contractor | 3 | 03/21/2026 |
| Andamio Scaffolding | Scaffold | 3 | 07/01/2026 |
| Jada Plumbing & Heating | Plumbing | 3 | 07/08/2026 |
| Singh Welding | specialty_contractor | 3 | 03/21/2026 |
| Peter Simon Restoration.c | specialty_contractor | 2 | 09/17/2026 |
| Sean Coakley P & H | Fire Protection | 2 | 07/08/2026 |
| The Renovated Home 1 | General Contractor | 2 | 07/08/2026 |
| Total Home Improvement SE | General Contractor | 2 | 07/08/2026 |
| Universal Management & Cont | General Contractor | 2 | 03/21/2026 |
| National Maintenance | Sign hanger | 2 | 07/08/2026 |
| DGC Capital Contracting | General Contractor | 2 | 04/09/2026 |
| Prime Electrical | Electrical | 2 | 03/22/2026 |
| Full Capacity Fire | Fire Protection | 2 | 06/02/2026 |
| Full Circle Plumbing | Plumbing | 2 | 10/06/2026 |
| Vlashava Electric Contracting | Electrical | 2 | 03/21/2026 |
| Ultimate Signs & Designs Co | Sign hanger | 2 | 07/08/2026 |
| Pipestylists | Plumbing | 2 | 07/08/2026 |
| Wawel Plumbing and Heating | Plumbing | 1 | 09/30/2026 |
| I.K.E. Electrical | Electrical | 1 | 03/22/2026 |
| V.R. Electrical | Electrical | 1 | 03/22/2026 |
| Afgo Mechanical Services | specialty_contractor | 1 | 07/08/2026 |
| Avacon Management | General Contractor | 1 | 07/08/2026 |
| Carleton Restoration | specialty_contractor | 1 | 07/08/2026 |
| Celtic Services NYC | General Contractor | 1 | 07/08/2026 |
| Empire Ecs | General Contractor | 1 | 07/08/2026 |
| Everest Scaffolding | Scaffold | 1 | 07/08/2026 |
| Exterior Wall & Building | Scaffold | 1 | 04/09/2026 |
| Intersystem Installation | Scaffold | 1 | 07/08/2026 |
| Urban Intelligence | Scaffold | 1 | 06/02/2026 |
| Ark-Pol Plumbing | Plumbing | 1 | 07/08/2026 |
| Bedrock Plumbing & Heating | Plumbing | 1 | 07/08/2026 |
| EH Plumbing & Heating | Plumbing | 1 | 07/08/2026 |
| Ethos Plumbing | Plumbing | 1 | 07/08/2026 |
| Gregg NY Plumbing | Plumbing | 1 | 07/08/2026 |
| P.S.I. Mechanical | Plumbing | 1 | 07/08/2026 |
| Safety Fire Sprinkler | Fire Protection | 1 | 07/08/2026 |
| Shaw Mechanical | Plumbing | 1 | 07/08/2026 |
| Gsa Electric | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Domani Inspection Service | 843 | 99 | 10/08/2026 |
| Outsource Special Inspection | 2827 | 3 | 07/13/2026 |
| Aks Architectural & Engineering | 1957 | 7 | 05/21/2026 |
| Ryan Special Engineering | 2018 | 7 | 08/21/2025 |
| BP Architects | 2712 | 4 | 06/18/2025 |
| NY Restoration Technology | 6187 | 3 | 05/27/2025 |
| George J. Xerakias, PE | 1658 | 1 | 04/24/2025 |
| Vincent J. Liotta P. E | 1974 | 1 | 01/21/2025 |
| Skyline Engineering | 267 | 4 | 03/25/2024 |
| Integrity Consulting Service | 666 | 1 | 09/18/2023 |
| Vibranalysis Inc., Dba VT | 6864 | 1 | 12/14/2022 |
| Michael Gray Architect | 4478 | 2 | 02/18/2022 |
| Crafted Architecture | 6642 | 3 | 02/17/2022 |
| Yorkos Engineering, Desig | 6991 | 1 | 11/24/2021 |
| TSS Engineers | 4492 | 1 | 10/07/2021 |
| SE Inspections | 7486 | 1 | 08/11/2021 |
| DJ Associates Architect | 2852 | 2 | 06/09/2021 |
| Structural Engineering | 5699 | 1 | 06/09/2021 |
| AK Engineering | 678 | 4 | 02/04/2021 |
| Prudigm Engineering Llcu | 4304 | 3 | 01/19/2021 |
| Bendix Engineering | 4293 | 3 | 11/06/2020 |
| Zenesis Engineering/Architects | 1473 | 2 | 10/27/2020 |
| Winton Group Architecture | 4343 | 1 | 05/05/2020 |
| O'Rourke Engineering | 5873 | 1 | 03/02/2020 |
| Katz Engineering | 238 | 1 | 11/08/2019 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | Full Circle Plumbing | 10/05/2026 |
| DOB NOW | Plumbing | Permit Issued | Wawel Plumbing and Heating | 09/29/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Peter Simon Restoration.c | 09/16/2026 |
| DOB NOW | General Construction | Permit Issued | Peter Simon Restoration.c | 09/16/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 08/27/2026 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 08/27/2026 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 08/26/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 08/26/2026 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 08/26/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 08/25/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 08/25/2026 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 08/25/2026 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 08/25/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 08/25/2026 |
| DOB NOW | Plumbing | Permit Issued | Full Circle Plumbing | 08/19/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 08/04/2026 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 07/31/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 07/29/2026 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 07/28/2026 |
| DOB NOW | Sidewalk Shed | Signed-off | Andamio Scaffolding | 06/29/2026 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 06/29/2026 |
| DOB NOW | General Construction | Signed-off | Building Code Partners | 06/15/2026 |
| DOB NOW | Sidewalk Shed | Permit Issued | Urban Intelligence | 05/20/2026 |
| DOB NOW | General Construction | Signed-off | Building Code Partners | 05/06/2026 |
| DOB NOW | General Construction | Signed-off | Building Code Partners | 05/06/2026 |
| DOB NOW | Sidewalk Shed | Signed-off | Andamio Scaffolding | 04/02/2026 |
| DOB NOW | Sprinklers | Signed-off | Full Capacity Fire | 03/31/2026 |
| DOB NOW | Plumbing | Signed-off | A & M Warshaw Plumbing & Heating | 03/09/2026 |
| DOB NOW | Plumbing | Signed-off | A & M Warshaw Plumbing & Heating | 02/18/2026 |
| DOB NOW | Plumbing | Signed-off | A & M Warshaw Plumbing & Heating | 02/18/2026 |
| DOB NOW | Suspended Scaffold | Permit Issued | Canido Basonas Construction | 02/12/2026 |
| DOB NOW | Plumbing | Permit Issued | A & M Warshaw Plumbing & Heating | 12/26/2025 |
| DOB NOW | General Construction | Signed-off | Building Code Partners | 12/23/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 12/05/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | Building Code Partners | 11/28/2025 |
| DOB NOW | General Construction | Permit Issued | Canido Basonas Construction Service | 11/17/2025 |
| DOB NOW | Plumbing | Signed-off | Jada Plumbing & Heating | 11/17/2025 |
| DOB NOW | Plumbing | Signed-off | Jada Plumbing & Heating | 11/17/2025 |
| DOB NOW | Mechanical Systems | Signed-off | Building Code Partners | 11/13/2025 |
| DOB NOW | General Construction | Permit Issued | Building Code Partners | 11/13/2025 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/08/2026 | Permit Issued | Building Code Partners | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Daikin FXNQ09MVJU9 9,500 BTU · Vrf Indoor ×8 FXMQ12PBVJU 12,000 BTU · Vrf Indoor ×6 FXMQ09PBVJU 9,500 BTU · Vrf Indoor ×4 BS12Q54TVJ 290,000 BTU · Vrf Indoor ×2 FXAQ07PVJU 7,500 BTU · Vrf Indoor ×2 FXMQ24PBVJU 24,000 BTU · Vrf Indoor ×2 FXMQ30PBVJU 30,000 BTU · Vrf Indoor ×2 RWEQ144TATJA 138,000 BTU · Vrf Outdoor ×2 Ventilation Greenheck CSP-A390 150 CFM · Exhaust Fan ×2 |
| 10/07/2026 | Permit Issued | Building Code Partners | Heating and Air Conditioning Systems | Heat / Cool Daikin FXNQ12MVJU9 12,000 BTU · Vrf Indoor ×2 FXSQ12TBVJU 12,000 BTU · Vrf Indoor ×2 BS8Q54TVJ 290,000 BTU · Vrf Outdoor ×1 FXAQ07PVJU 7,500 BTU · Vrf Indoor ×1 FXMQ15TBVJU 14,200 BTU · Vrf Indoor ×1 FXMQ18TBVJU 18,000 BTU · Vrf Indoor ×1 RWEYQ84PCTJ-HR 80,000 BTU · Vrf Outdoor ×1 |
| 07/20/2026 | Permit Issued | Building Code Partners | Heating and Air Conditioning Systems | Heat / Cool Daikin FXMQ18PBVJU 18,000 BTU · Vrf Indoor ×2 BS8Q54TVJ 290,000 BTU ×1 FXMQ09PBVJU 9,500 BTU · Vrf Indoor ×1 FXMQ12PBVJU 12,000 BTU · Vrf Indoor ×1 FXMQ24PBVJU 24,000 BTU · Vrf Indoor ×1 RWEYQ84PCIJ-HR 90,000 BTU · Vrf Outdoor ×1 |
| 07/13/2026 | Permit Issued | Building Code Partners | Air Conditioning Systems, Ventilation Systems | |
| 02/19/2026 | Signed-off | Building Code Partners | Air Conditioning Systems, Ventilation Systems | Cooling Daikin FXMQ18PBVJU 18,000 BTU · Vrf Indoor ×3 BSF8Q54TVJ 290,000 BTU · Controls ×1 FXAQ07PVJU 7,500 BTU · Vrf Indoor ×1 FXMQ07PBVJU 7,500 BTU · Vrf Indoor ×1 FXMQ09PBVJU 9,500 BTU · Vrf Indoor ×1 FXMQ24PBVJU 24,000 BTU · Vrf Indoor ×1 RWEYQ84PTJU-HR 80,000 BTU · Vrf Outdoor ×1 Ventilation Greenheck CSP-A390-VG 150 CFM · Exhaust Fan ×1 |
| 07/14/2025 | — | — | Heating and Air Conditioning Systems | Heat / Cool Daikin DAIKIN / FXDQ18MVJU 20,000 BTU · Vrf Indoor ×2 DAIKIN / FXDQ12MVJU 13,500 BTU · Fan Coil Indoor ×1 DAIKIN / FXNQ18MVJU9 20,000 BTU · Vrf Indoor ×1 DAIKIN / RWEQ96TBTJA-HR 8 tons · Vrf Outdoor ×1 DAIKIN/FXDQ12MVJU 13,500 BTU · Vrf Indoor ×1 DAIKIN/FXDQ18MVJU 20,000 BTU · Vrf Indoor ×1 |
| 05/20/2025 | Signed-off | Building Code Partners | Heating and Air Conditioning Systems | Heat / Cool Daikin FXMQ18TBVJU 18,000 BTU · Vrf Indoor ×2 BS6Q54TVJ 216,000 BTU · Vrf Outdoor ×1 FXAQ07PVJU 7,500 BTU · Vrf Indoor ×1 FXSQ07TBVJU 7,500 BTU · Vrf Indoor ×1 FXSQ09TBVJU 9,500 BTU · Vrf Indoor ×1 FXSQ12TBVJU 12,000 BTU · Vrf Indoor ×1 RWEYQ72PCTJ 69,000 BTU · Vrf Outdoor ×1 |
| 03/25/2024 | Signed-off | Building Code Partners | Heating and Air Conditioning Systems | Heat / Cool Daikin FXSQ09TBVJU 9,500 BTU · Vrf Indoor ×2 FXSQ12TBVJU 12,000 BTU · Vrf Indoor ×2 FXSQ07TBVJU 7,500 BTU · Vrf Indoor ×1 FXSQ07TMVJU 7,500 BTU · Vrf Indoor ×1 FXSQ18TBVJU 18,000 BTU · Vrf Indoor ×1 RWEYQ72PCTJ 86,110 BTU · Vrf Outdoor ×1 |
| 11/24/2021 | — | — | Air Conditioning Systems, Associated Ducts and Piping, Ventilation Systems | Cooling Water Furnace USH012SR000CANNA8D42SSD 12,370 BTU · Wshp ×2 USH015SR001CANNA8N42SSD 13,480 BTU · Wshp ×2 USH023SR001CANNA8N00SSD 22,320 BTU · Wshp ×2 Ventilation Panasonic FV-0511VK2 51 CFM · Exhaust Fan ×4 Ducts & Piping N/A n/a Ductwork ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/21/2026 | Signed-off | Full Capacity Fire | 44 heads |
| 10/25/2022 | — | — | 18 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/08/2026 | Permit Issued | A & M Warshaw Plumbing & Heating | Gas, Water/Sanitary |
| 10/07/2026 | Permit Issued | Full Circle Plumbing | Gas, Water/Sanitary |
| 09/28/2026 | — | — | Gas, Water/Sanitary |
| 07/20/2026 | — | — | Gas, Water/Sanitary |
| 07/13/2026 | Permit Issued | Full Circle Plumbing | Water/Sanitary |
| 05/21/2026 | Signed-off | Shaw Mechanical | Water/Sanitary |
| 02/19/2026 | Signed-off | A & M Warshaw Plumbing & Heating | Gas, Water/Sanitary |
| 02/19/2026 | Signed-off | A & M Warshaw Plumbing & Heating | Gas, Water/Sanitary |
| 07/14/2025 | — | — | Gas, Water/Sanitary |
| 05/20/2025 | Signed-off | A & M Warshaw Plumbing & Heating | Gas, Water/Sanitary |
| 03/25/2024 | Signed-off | A & M Warshaw Plumbing & Heating | Gas, Water/Sanitary |
| 03/16/2023 | Signed-off | A & M Warshaw Plumbing & Heating | Water/Sanitary |
| 10/25/2022 | — | — | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/16/2026 | Permit Issued | I.K.E. Electrical | General Wiring |
| 08/20/2026 | Permit Issued | Vlashava Electric Contracting | General Wiring |
| 12/23/2025 | Complete | Vlashava Electric Contracting | — |
| 12/16/2025 | Permit Issued | Cresco Electrical | General Wiring |
| 08/12/2025 | Complete | Vlashava Electric Contracting | — |
| 06/14/2025 | Complete | 5 J'S Electl Conts | — |
| 04/22/2025 | Complete | Borowide Elect'l Contractors | — |
| 02/11/2025 | Complete | Vlashava Electric Contracting | — |
| 02/11/2025 | Complete | Vlashava Electric Contracting | — |
| 01/30/2025 | Complete | Vlashava Electric Contracting | — |
| 05/14/2024 | Complete | Vlashava Electric Contracting | — |
| 04/16/2024 | Complete | Iconic Electric | General Wiring |
| 03/05/2024 | Complete | Vlashava Electric Contracting | — |
| 08/03/2023 | Complete | Conde Electric | General Wiring |
| 07/29/2023 | Complete | MLB Electrical | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/05/2025 | Permit Issued | Urban Intelligence | Sidewalk Shed |
| 04/24/2025 | Signed-off | Andamio Scaffolding | Sidewalk Shed |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/24/2025 | Permit Issued | Canido Basonas Construction | Suspended Scaffold (SC) |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/24/2026 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 05/08/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 05/08/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 05/06/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 03/12/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 01/15/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 01/14/2026 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 01/14/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 01/12/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 01/08/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 01/08/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 12/24/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 11/21/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/21/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 11/20/2025 | Fail-Final General Construction Non-Directive 14 | Fail | View ↗ |
| 11/13/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 11/13/2025 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 10/03/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 10/01/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 06/25/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/12/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/14/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 10/03/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/05/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 08/05/2024 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/07/2026 | Fire-Resistant Penetrations and Joints | JOHN MCMONAGLE | special |
| 10/05/2026 | HVAC-R and service water piping design and insulation | JOHN MCMONAGLE | energy_progress |
| 10/05/2026 | HVAC-R and service water heating system controls | JOHN MCMONAGLE | energy_progress |
| 10/05/2026 | Fire-Resistant Penetrations and Joints | JOHN MCMONAGLE | special |
| 10/05/2026 | Maintenance information | JOHN MCMONAGLE | energy_progress |
| 07/07/2026 | Tenant Protection Plan Compliance | JONAR MADRIAGA | special |
| 07/07/2026 | Tenant Protection Plan Compliance | JONAR MADRIAGA | special |
| 07/06/2026 | Air barrier - visual inspection | JONAR MADRIAGA | energy_progress |
| 07/06/2026 | Insulation placement and R values | JONAR MADRIAGA | energy_progress |
| 07/06/2026 | Lighting controls | JONAR MADRIAGA | energy_progress |
| 07/02/2026 | Lighting in dwelling units | JONAR MADRIAGA | energy_progress |
| 07/02/2026 | Energy Code Compliance Inspections | JONAR MADRIAGA | progress |
| 07/02/2026 | Energy Code Compliance Inspections | JONAR MADRIAGA | progress |
| 07/02/2026 | Energy Code Compliance Inspections | JONAR MADRIAGA | progress |
| 07/02/2026 | Interior lighting power | JONAR MADRIAGA | energy_progress |
| 06/18/2026 | Energy Code Compliance Inspections | JOHN MCMONAGLE | progress |
| 06/18/2026 | Energy Code Compliance Inspections | JOHN MCMONAGLE | progress |
| 06/16/2026 | Energy Code Compliance Inspections | JOHN MCMONAGLE | progress |
| 06/16/2026 | Metering | JOHN MCMONAGLE | energy_progress |
| 06/16/2026 | HVAC-R and service water heating equipment | JOHN MCMONAGLE | energy_progress |
| 06/16/2026 | Maintenance information | JOHN MCMONAGLE | energy_progress |
| 06/16/2026 | HVAC-R and service water piping design and insulation | JOHN MCMONAGLE | energy_progress |
| 06/16/2026 | Duct leakage testing, insulation and design | JOHN MCMONAGLE | energy_progress |
| 06/16/2026 | HVAC-R and service water heating system controls | JOHN MCMONAGLE | energy_progress |
| 06/09/2026 | HVAC-R and service water heating equipment | JOHN MCMONAGLE | energy_progress |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| CVS Pharmacy | Retail | Sub-basement | Project M01100330 |
| Starbucks | Restaurant / Food Service | Cellar, Floor 1 | Project M08050406 Project M08050454 |
| The Belnord Retail Store | Retail | Floors 1, 10 | Project M00327806 Project M00588734 |