← Back
BuildNYC
Five to six families
248 HENRY STREET
BROOKLYN · Brooklyn Heights · BIN 3002436
💬 Discuss this project
1849Year Built
3.5Stories
C2Building Class
R6Zoning
5,085 sfGross Floor Area
6Units
Rent Stabilized14 Active Violations 3 likely answered ▸
Five to six families · Owner of record: 248 Henry · 2,174 sf lot · 2.34 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 4Cellar plumbing and gas riser9p · 3 filings · 20 docs
Floor 3Cellar plumbing and gas riser10p · 3 filings · 20 docs
Floor 2Cellar plumbing and gas riser11p · 4 filings · 20 docs
Floor 1Cellar plumbing and gas riser8p · 3 filings · 20 docs
CellarCellar plumbing and gas riser11p · 3 filings · 20 docs
BasementCellar plumbing and gas riser2p · 2 filings · 20 docs
Sub-BasementCellar plumbing and gas riser9p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
293 Henry3108/07/2026
248 Henry103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/15/2021$3.0M—HARBOUR VIEW ENTERPRISES, INC. → 248 HENRY LLC$590/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Hamann Engineering812/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Big Orange Expediting1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Orbit Plumbing & HeatingPlumbing708/07/2026
Big Orange Safety FirstGeneral Contractor407/08/2026
Rock Face ConstructionGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Hamann Engineering4949712/30/2025
Building Lifecycle
10/14/2026
Closed: Failure to file 2022 external low pressure inspection
DOB violation · closed on the city's record
09/29/2026
Boiler inspection report filed
Initial · no defects · Accepted
08/06/2026
Permit issued — Boiler Equipment
B00661143-S1-BE
08/05/2026
Permit issued — Boiler Equipment
B00661143-S2-BE
05/13/2026
Permit renewed — Plumbing
Renewed without changes
B00661143-I1-PL
169 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offOrbit Plumbing & Heating08/06/2026
DOB NOWBoiler EquipmentSigned-offOrbit Plumbing & Heating08/05/2026
DOB NOWPlumbingPermit IssuedOrbit Plumbing & Heating05/13/2026
DOB NOWPlumbingPermit IssuedOrbit Plumbing & Heating04/30/2025
DOB NOWPlumbingPermit IssuedOrbit Plumbing & Heating05/29/2024
DOB NOWGeneral ConstructionPermit IssuedRock Face Construction11/02/2023
DOB NOWGeneral ConstructionSigned-offRock Face Construction10/11/2023
DOB NOWPlumbingPermit IssuedOrbit Plumbing & Heating05/04/2023
DOB NOWGeneral ConstructionSigned-offBig Orange Safety First11/21/2022
DOB NOWGeneral ConstructionSigned-offBig Orange Safety First11/21/2022
DOB NOWPlumbingPermit IssuedOrbit Plumbing & Heating06/02/2022
DOB NOWMechanical SystemsSigned-offBig Orange Safety First05/28/2022
DOB NOWGeneral ConstructionSigned-offBig Orange Safety First01/26/2022
1 project · most recent 12/30/2025
Gas Water/Sanitary
FiledStatusContractorScope
12/30/2025Signed-offOrbit Plumbing & HeatingGas, Water/Sanitary
1 project · most recent 03/24/2022
General Wiring
FiledStatusContractorScope
03/24/2022Permit IssuedDennison ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
04/03/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/27/2026Fail-Final CND-Occupancy InspectionFailView ↗
01/27/2026Pass-Final CND-Occupancy InspectionPassView ↗
12/31/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/11/2025Fail-Final CND-Occupancy InspectionFailView ↗
10/28/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/23/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/23/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/29/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
12/30/2025Maintenance informationCARL HAMANNenergy_progress
12/23/2025HVAC-R and service water heating system controlsCARL HAMANNenergy_progress
12/23/2025Maintenance informationCARL HAMANNenergy_progress
12/23/2025HVAC-R and service water piping design and insulationCARL HAMANNenergy_progress
12/23/2025Tenant Protection Plan ComplianceCARL HAMANNspecial
12/23/2025HVAC-R and service water heating equipmentCARL HAMANNenergy_progress
12/23/2025HVAC-R and service water heating equipmentCARL HAMANNenergy_progress
12/23/2025Tenant Protection Plan ComplianceCARL HAMANNspecial
12/23/2025HVAC-R and service water piping design and insulationCARL HAMANNenergy_progress
12/23/2025HVAC-R and service water heating system controlsCARL HAMANNenergy_progress
05/30/2025Fire-Resistant Penetrations and JointsCARL HAMANNspecial
11/08/2023Fire-Resistant Penetrations and JointsCARL HAMANNspecial
02/15/2023Fire-Resistant Penetrations and JointsCARL HAMANNspecial
02/15/2023Tenant Protection Plan ComplianceCARL HAMANNspecial
05/18/2022Fire-Resistance Rated ConstructionCARL HAMANNprogress
05/04/2022Fire-Resistant Penetrations and JointsCARL HAMANNspecial
01/12/2022FinalCARL HAMANNprogress
01/12/2022Mechanical SystemsCARL HAMANNspecial
50 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account