Rent Stabilized0 Active ViolationsFDNY Report ↗
Miscellaneous two family · 1,761 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 18p · 1 filing · 20 docs
Cellar7p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
251 45th Street103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/25/2022$990K—251 45TH STREET INC. → Private party$589/sf building
04/07/2017$838K—— → —$499/sf building
02/01/2016$600K—— → —$357/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Yang Engineering506/18/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SD Design Studio603/21/2026
JRL Skyline403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Acer ConstructionGeneral Contractor303/21/2026
American Standard P&H CororpPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Yang Engineering8376506/18/2023
Building Lifecycle
All (49)Filed (5)Permit Issued (2)Signed Off (2)Violation (9)Inspection (5)Objection (14)Special Inspection (12)
11/28/2023
Violation issued (HPD, closed)
I
09/18/2023
Signed off — Alteration
PROPOSED INTERIOR RENOVATION ON CEL. & 1ST FLOOR. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B00803431-I1
08/22/2023
Signed off — Alteration
PROPOSED INTERIOR RENOVATION ON CEL. & 1ST FLOOR. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B00803431-S1
08/08/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/03/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/17/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jian Yang
06/18/2023
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON CEL. & 1ST FLOOR. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B00803431-P3
06/14/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
05/19/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/19/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/24/2023
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON CEL. & 1ST FLOOR. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B00803431-P2
04/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jian Yang
04/21/2023
Special inspection requirement — Mechanical Systems
Jian Yang
04/21/2023
Special inspection requirement — Energy Code Compliance Inspections
Jian Yang
04/21/2023
Special inspection requirement — Final
Jian Yang
04/21/2023
Special inspection requirement — Fire-Resistance Rated Construction
Jian Yang
04/21/2023
Special inspection requirement — HVAC-R and service water heating equipment
Jian Yang
04/21/2023
Special inspection requirement — HVAC-R and service water heating system controls
Jian Yang
04/21/2023
Special inspection requirement — Interior lighting power
Jian Yang
04/21/2023
Special inspection requirement — Maintenance information
Jian Yang
04/21/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Jian Yang
04/13/2023
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON CEL. & 1ST FLOOR. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B00803431-P1
04/07/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jian Yang
02/17/2023
Permit issued — Plumbing
B00803431-S1-PL
02/10/2023
Permit issued — General Construction
B00803431-I1-GC-CX
01/25/2023
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON CEL. & 1ST FLOOR. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B00803431-S1
01/06/2023
Objection raised — Other
01/06/2023
Objection resolved — Addressed
01/06/2023
Objection raised — Other
01/06/2023
Objection resolved — Addressed
01/06/2023
Objection raised — Other
01/06/2023
Objection resolved — Addressed
01/06/2023
Objection raised — Other
01/06/2023
Objection resolved — Addressed
01/06/2023
Objection raised — Energy
01/06/2023
Objection resolved — Addressed
01/06/2023
Objection raised — Other
01/06/2023
Objection resolved — Addressed
01/06/2023
Objection raised — Other
01/06/2023
Objection resolved — Addressed
12/27/2022
Filed — Alteration
PROPOSED INTERIOR RENOVATION ON CEL. & 1ST FLOOR. CEILING, FLOORING & PARTITION WORKS AS PER PLAN. NO CHANGE IN USE, BULK, EGRESS OR OCCUPANCY.
B00803431-I1
11/17/2022
Violation issued (HPD, closed)
I
04/05/2022
Violation issued (HPD, closed)
B
04/05/2022
Violation issued (HPD, closed)
B
04/05/2022
Violation issued (HPD, closed)
B
06/27/2018
Violation issued (HPD, closed)
B
06/27/2018
Violation issued (HPD, closed)
C
06/27/2018
Violation issued (HPD, closed)
B
06/27/2018
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAmerican Standard P&H Cororp02/17/2023
DOB NOWGeneral ConstructionSigned-offAcer Construction02/10/2023
BISOTISSUEDLin's Associates05/10/2017
BISPLISSUEDCatman Plumbing05/10/2017
2 projects · most recent 07/13/2023
General Wiring
FiledStatusContractorScope
07/13/2023CompleteAll Around ElectricGeneral Wiring
11/15/2022CompleteJ Y Electric3 meters, 3 new_meters
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/08/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/03/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/14/2023Pass-Final General Construction Non-Directive 14PassView ↗
05/19/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/19/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
07/17/2023Fire-Resistant Penetrations and JointsJian Yangspecial
04/21/2023Fire-Resistant Penetrations and JointsJian Yangspecial
04/21/2023Mechanical SystemsJian Yangspecial
04/21/2023Energy Code Compliance InspectionsJian Yangprogress
04/21/2023FinalJian Yangprogress
04/21/2023Fire-Resistance Rated ConstructionJian Yangprogress
04/21/2023HVAC-R and service water heating equipmentJian Yangenergy_progress
04/21/2023HVAC-R and service water heating system controlsJian Yangenergy_progress
04/21/2023Interior lighting powerJian Yangenergy_progress
04/21/2023Maintenance informationJian Yangenergy_progress
04/21/2023HVAC-R and service water piping design and insulationJian Yangenergy_progress
04/07/2023Fire-Resistant Penetrations and JointsJian Yangspecial
▾Documents — 53 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/28/2026B00803431-S1Request digital key ↗
08/28/2026B00803431-P3Request digital key ↗
08/28/2026B00803431-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION3
07/11/2017340497386Open ↗
07/11/2017340497386Open ↗
04/27/2017340497386Open ↗
▸BISWORK PERMIT APPLICATION2
05/10/2017340497386Open ↗
05/10/2017340497386Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
05/03/2017340497386Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWRestrictive Declaration/Easement 15
08/28/2026B00803431-S1Open ↗
08/15/2026B00803431-I1Open ↗
08/13/2026B00803431-P1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/28/2026B00803431-I1Open ↗
08/13/2026B00803431-P2Open ↗
08/13/2026B00803431-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/31/2026B00803431-P2Open ↗
08/27/2026B00803431-S1Open ↗
08/25/2026B00803431-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/31/2026B00803431-P2Open ↗
08/31/2026B00803431-P2Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/27/2017340497386Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/27/2017340497386Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/16/2017340497386Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/27/2017340497386Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING1
04/27/2017340497386Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
06/09/2017340497386Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/28/2026B00803431-S1Open ↗
08/15/2026B00803431-I1Open ↗
08/13/2026B00803431-P3Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/27/2017340497386Open ↗
▸Energy Compliance4
▸BISAS-BUILT ENERGY ANALYSIS1
08/16/2017340497386Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
04/27/2017340497386Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/16/2017340497386Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
04/27/2017340497386Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/27/2017340497386Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
08/16/2017340497386Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/16/2017340497386Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
08/16/2017340497386Open ↗
05/03/2017340497386Open ↗
04/27/2017340497386Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION5
08/07/2017340497386Open ↗
07/11/2017340497386Open ↗
05/11/2017340497386Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
04/27/2017340497386Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
08/16/2017340497386Open ↗