← Back
One story retail building
2616 OCEAN PARKWAY
BROOKLYN · BIN 3196063
💬 Discuss this project
1931Year Built
1Stories
K1Building Class
R5Zoning
1,626 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story retail building · Owner of record: 2616 OCEAN PARKWAY, · 2,600 sf lot · 0.63 FAR built · Flood zone X500
Locations of Work
Mechanical
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 5 docs
Floor 1Under Construction2p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2616 OCEAN PARKWAY,303/22/2026
NONA103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BITOPI CONSULTANTS LLC103/05/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUPERIOR FIRE CONTROL103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
METAL CRAFTS BY N BARSILYElectrical103/21/2026
SILVER, HUGHElectrical103/21/2026
SITRUK, MAURICEElectrical103/21/2026
TOUEY, CHRISTOPHERElectrical103/21/2026
AMC EXHAUST SYSTEM LLCGeneral Contractor106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036103/05/2026
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Violation (9)Special Inspection (2)
03/12/2026
Permit issued — Mechanical Systems
B01364961-I1-MS
03/05/2026
Filed — Alteration
Filing to install Deli Kitchen hood and ductwork as per plans. No change in use, egress or occupancy.
B01364961-I1
02/26/2026
Special inspection requirement — Mechanical Systems
KAMRUL AHSAN
02/26/2026
Special inspection requirement — Final
KAMRUL AHSAN
11/21/2025
Violation issued (ECB, closed)
Plumbing
08/01/2025
Violation issued (FDNY_ORDER, closed)
08/01/2025
Violation issued (FDNY_ORDER, closed)
08/01/2025
Violation issued (FDNY_ORDER, closed)
02/16/2024
Violation issued (ECB, closed)
Construction
10/05/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/27/2016
Violation issued (FDNY_ORDER, closed)
07/13/2016
Violation issued (ECB, closed)
Construction
03/07/1988
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedAMC EXHAUST SYSTEM LLC03/12/2026
BISOTISSUEDHV DRAFTING & DESIGN ASSO12/20/2016
BISOTISSUEDHV DRAFTING & DESIGN ASSO05/09/2016
BISOTISSUEDPALONE BROTHERS AIR01/28/2011
BISFPISSUEDN Y BUSINESS FIRE SYSTEM INC10/22/2001
BISFPISSUEDNY BUSINESS FIRE SYSTEM10/12/1999
BISOTISSUEDALGO CONSTRUCTION CORP01/23/1998
BISMHISSUEDALGO CONSTRUCTION CORP01/22/1998
BISFPISSUEDMASTER FIRE PREVENTION SYSTEMS10/10/1991
1 project · most recent 03/05/2026
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/05/2026Permit IssuedAMC EXHAUST SYSTEM LLCVentilation Systems
Ventilation
Dayton 56JN93 5,000 CFM · Kitchen Exhaust ×1
1 project · most recent 04/11/2024
General Wiring
FiledStatusContractorScope
04/11/2024Permit IssuedKWONG MING ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
02/26/2026Mechanical SystemsKAMRUL AHSANspecial
02/26/2026FinalKAMRUL AHSANprogress
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026B01364961-I1Request digital key ↗
▸Applications & Permits7
▸BISWORK PERMIT APPLICATION4
12/21/2016321495529Open ↗
05/10/2016321380732Open ↗
01/31/2011320242475Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
12/20/2016321495529Open ↗
05/10/2016321380732Open ↗
12/10/2010320242475Open ↗
▸Seals & Professional Certifications11
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
12/20/2016321495529Open ↗
05/10/2016321380732Open ↗
02/14/2011320242475Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
12/20/2016321495529Open ↗
05/10/2016321380732Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
12/20/2016321495529Open ↗
05/10/2016321380732Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026B01364961-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/23/2026B01364961-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/23/2026B01364961-I1Open ↗
▸Trade Schedules & Equipment2
▸BISEQUIPMENT USE APPLICATION/PERMIT2
12/10/2010320242475Open ↗
02/24/2011320242475Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
12/10/2010320242475Open ↗
▸Environmental & Asbestos3
▸BISTHIS IS NOT AN ASBESTOS PROJECT1
11/18/2010320242475Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/10/2016321380732Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026B01364961-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
12/20/2016321495529Open ↗
05/10/2016321380732Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
11/10/2016321380732Open ↗
02/14/2011320242475Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
12/10/2010320242475Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
12/20/2016321495529Open ↗
11/10/2016321380732Open ↗
05/10/2016321380732Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
12/15/2016321495529Open ↗
05/10/2016321380732Open ↗