← Back
BROOKLYN
Montrose Gallery Condominium
27 MONTROSE AVENUE · East Williamsburg · BIN 3427461
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open ViolationsFDNY Report ↗
Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentLandscapeGeneralOther
Roof76p · 5 filings · 20 docs
Floor 677p · 4 filings · 20 docs
Floor 573p · 4 filings · 20 docs
Floor 475p · 4 filings · 20 docs
Floor 370p · 4 filings · 20 docs
Floor 273p · 4 filings · 20 docs
Floor 175p · 6 filings · 20 docs
Cellar67p · 3 filings · 20 docs
Site & exterior26p · 3 filings · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
UGB CONSTRUCTION807/08/2026
JASCO707/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHOSEN MEP, CORP.1012/11/2024
STRUCTURAL ENGINEERING TECHNOLOGIES201/16/2024
ASHRAF CORP408/02/2023
ASR ENGINEERING PC104/05/2023
MOHAMMAD AHEAD, PE105/18/2022
H & O ENGINEERING, DPC105/02/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CODE2403/21/2026
ADVANCED BUILDERS SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
UGB CONSTRUCTION INCGeneral Contractor807/08/2026
JASCO, INCGeneral Contractor207/08/2026
USMAN G. BHUTTAGeneral Contractor203/21/2026
AVESTA BUILDERS INCGeneral Contractor207/08/2026
DOUG'S PLBG & HTG SERV COFire Protection207/08/2026
ZONE PLUMBING & HEATING CPlumbing107/08/2026
T.M.T ELECTRIC INCElectrical103/22/2026
BEST FITOUTS, LLCGeneral Contractor107/08/2026
DONATO PLUMBING, INCPlumbing107/08/2026
RICHARD NEUElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616612/02/2024
Building Lifecycle
All (95)Filed (19)Permit Issued (13)Signed Off (9)Inspection (8)Objection (16)Special Inspection (30)
01/28/2025
Signed off — Alteration
B00264615-I1
01/27/2025
Signed off — Alteration
POST APPROVAL AMENDMENT FILED HEREWITH TO AMEND CODE COMPLIANCE PATH FROM NYCECC TO ASHRAE 90.1.
B00257999-I1
12/26/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
12/24/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/13/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
12/13/2024
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
12/13/2024
Special inspection requirement — HVAC and service water heating equipment
FAHAD FATEH
12/13/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
12/13/2024
Special inspection requirement — HVAC and service water heating system controls
FAHAD FATEH
12/13/2024
Special inspection requirement — HVAC insulation and sealing
FAHAD FATEH
12/13/2024
Special inspection requirement — Heating Systems
FAHAD FATEH
12/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
12/13/2024
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
12/13/2024
Special inspection requirement — Mechanical Systems
FAHAD FATEH
12/13/2024
Special inspection requirement — Final
FAHAD FATEH
12/12/2024
Signed off — Alteration
B00264599-I1
12/11/2024
Filed — Alteration
B00264615-P3
12/09/2024
Objection raised — Other
12/09/2024
Objection resolved — Addressed
12/02/2024
Filed — Alteration
POST APPROVAL AMENDMENT FILED HEREWITH TO AMEND CODE COMPLIANCE PATH FROM NYCECC TO ASHRAE 90.1.
B00257999-P3
11/22/2024
Inspection — Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve Test
Certified
View inspection ↗
11/21/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
11/21/2024
Special inspection requirement — HVAC and service water heating system controls
FAHAD FATEH
11/21/2024
Special inspection requirement — HVAC insulation and sealing
FAHAD FATEH
11/21/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
11/21/2024
Special inspection requirement — HVAC and service water heating equipment
FAHAD FATEH
11/21/2024
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
11/21/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
11/21/2024
Special inspection requirement — Heating Systems
FAHAD FATEH
11/21/2024
Special inspection requirement — Mechanical Systems
FAHAD FATEH
11/21/2024
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
11/21/2024
Special inspection requirement — Final
FAHAD FATEH
11/06/2024
Special inspection requirement — Sprinkler Systems
FAHAD FATEH
10/31/2024
Filed — Alteration
B00264599-P2
10/10/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/08/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/29/2024
Signed off — Alteration
B00310946-I1
03/26/2024
Signed off — Alteration
STRUCTURAL WORK IN CONJUNCTION WITH CONSTRUCTION OF A NEW 6 STORY MULTIPLE DWELLING BUILDING WITH COMMUNITY FACILITY ON FIRST FLOOR (BIS #321595458). CONCRETE SLAB AND COLUMNS BRACED WITH ORDINARY REINFORCED SHEAR WALLS.
B00258517-I1
02/29/2024
Permit issued — Sprinklers
B00264599-I1-EW-SP
02/26/2024
Objection resolved — Addressed
02/26/2024
Special inspection requirement — Final
FAHAD FATEH
02/26/2024
Special inspection requirement — Concrete - Cast-In-Place
FAHAD FATEH
01/23/2024
Objection raised — Other
01/16/2024
Filed — Alteration
STRUCTURAL WORK IN CONJUNCTION WITH CONSTRUCTION OF A NEW 6 STORY MULTIPLE DWELLING BUILDING WITH COMMUNITY FACILITY ON FIRST FLOOR (BIS #321595458). CONCRETE SLAB AND COLUMNS BRACED WITH ORDINARY REINFORCED SHEAR WALLS.
B00258517-P1
01/10/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
01/10/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/28/2023
Special inspection requirement — Concrete - Cast-In-Place
FAHAD FATEH
12/28/2023
Special inspection requirement — Final
FAHAD FATEH
12/14/2023
Filed — Alteration
B00264615-P2
12/14/2023
Permit issued — Construction Fence
B00310946-I1-FN
12/13/2023
Permit issued — Mechanical Systems
B00257999-I1-MS
11/15/2023
Permit issued — Sprinklers
B00264599-I1-EW-SP
11/12/2023
Signed off — Alteration
INSTALLATION OF MEDIUM DUTY PIPE SCAFFOLD.
B00863137-I1
11/12/2023
Signed off — Alteration
INSTALLATION OF HEAVY DUTY SIDE WALK SHED.AS PER PLAN.
B00861665-I1
10/10/2023
Filed — Alteration
B00264599-P1
08/02/2023
Filed — Alteration
INSTALLATION OF MEDIUM DUTY PIPE SCAFFOLD.
B00863137-P1
05/18/2023
Permit issued — Plumbing
B00264615-I1-PL
05/07/2023
Filed — Alteration
INSTALLATION OF HEAVY DUTY SIDE WALK SHED.AS PER PLAN.
B00861665-P1
04/27/2023
Permit issued — Supported Scaffold
B00863137-I1-SF
04/22/2023
Filed — Alteration
INSTALLATION OF MEDIUM DUTY PIPE SCAFFOLD.
B00863137-I1
Latest 60 of 95 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offDOUG'S PLBG & HTG SERV CO02/29/2024
DOB NOWConstruction FenceSigned-offUGB CONSTRUCTION INC12/14/2023
DOB NOWMechanical SystemsSigned-offUGB CONSTRUCTION INC12/13/2023
DOB NOWSprinklersSigned-offDOUG'S PLBG & HTG SERV CO11/15/2023
DOB NOWPlumbingSigned-offZONE PLUMBING & HEATING C05/18/2023
DOB NOWSupported ScaffoldSigned-offUGB CONSTRUCTION INC04/27/2023
DOB NOWSidewalk ShedSigned-offUGB CONSTRUCTION INC04/21/2023
DOB NOWSidewalk ShedSigned-offJASCO, INC04/05/2023
DOB NOWStructuralSigned-offAVESTA BUILDERS INC03/24/2023
DOB NOWPlumbingSigned-offDONATO PLUMBING, INC01/18/2023
DOB NOWConstruction FenceSigned-offAVESTA BUILDERS INC12/09/2022
DOB NOWSidewalk ShedSigned-offJASCO, INC05/19/2022
DOB NOWConstruction FenceSigned-offBEST FITOUTS, LLC05/13/2022
5 projects · most recent 03/15/2024
General Wiring
FiledStatusContractorScope
03/15/2024CompleteT.M.T ELECTRIC INCGeneral Wiring
04/25/2023CompleteRICHARD NEU—
04/14/2023CompleteT.M.T ELECTRIC INC—
02/27/2023CompletePOWER DIRECT ELECTRIC INC—
05/30/2022CompleteRICHARD NEU—
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
12/26/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
12/24/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/22/2024Certified Sprinkler-Dry Pipe Valve (SP)-Dry Pipe Valve TestCertifiedView ↗
10/10/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/08/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/10/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
01/10/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/24/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 39
DateRequirementInspectorRole
12/13/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
12/13/2024Fire-Resistance Rated ConstructionFAHAD FATEHprogress
12/13/2024HVAC and service water heating equipment FAHAD FATEHenergy_progress
12/13/2024Maintenance informationFAHAD FATEHenergy_progress
12/13/2024HVAC and service water heating system controls FAHAD FATEHenergy_progress
12/13/2024HVAC insulation and sealing FAHAD FATEHenergy_progress
12/13/2024Heating SystemsFAHAD FATEHspecial
12/13/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
12/13/2024Post-installed AnchorsFAHAD FATEHspecial
12/13/2024Mechanical SystemsFAHAD FATEHspecial
12/13/2024FinalFAHAD FATEHprogress
11/21/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
11/21/2024HVAC and service water heating system controls FAHAD FATEHenergy_progress
11/21/2024HVAC insulation and sealing FAHAD FATEHenergy_progress
11/21/2024Maintenance informationFAHAD FATEHenergy_progress
11/21/2024HVAC and service water heating equipment FAHAD FATEHenergy_progress
11/21/2024Fire-Resistance Rated ConstructionFAHAD FATEHprogress
11/21/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
11/21/2024Heating SystemsFAHAD FATEHspecial
11/21/2024Mechanical SystemsFAHAD FATEHspecial
11/21/2024Post-installed AnchorsFAHAD FATEHspecial
11/21/2024FinalFAHAD FATEHprogress
11/06/2024Sprinkler SystemsFAHAD FATEHspecial
02/26/2024FinalFAHAD FATEHprogress
02/26/2024Concrete - Cast-In-PlaceFAHAD FATEHspecial
Latest 25 of 39.
▾Documents — 170 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch6
08/29/2026B00739458-I1Request digital key ↗
08/27/2026B00855134-I1Request digital key ↗
08/27/2026B00863137-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Plumbing4
08/23/2026B00264615-I1Request digital key ↗
08/23/2026B00264615-P3Request digital key ↗
08/15/2026B00264615-P2Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems3
09/02/2026B00257999-I1Request digital key ↗
08/15/2026B00257999-P3Request digital key ↗
08/15/2026B00257999-P2Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler3
09/02/2026B00264599-P1Request digital key ↗
09/02/2026B00264599-I1Request digital key ↗
08/15/2026B00264599-P2Request digital key ↗
▸DOB NOWPlans/Sketch - Structural2
08/15/2026B00258517-P1Request digital key ↗
08/15/2026B00258517-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/29/2026B00310946-I1Request digital key ↗
▸Applications & Permits32
▸BISPLAN / WORK APPROVAL APPLICATION17
12/03/2024321595458Open ↗
11/15/2024321595458Open ↗
06/05/2023322160326Open ↗
Showing 3 of 17 on file for this type
▸BISWORK PERMIT APPLICATION13
02/08/2024321595458Open ↗
08/08/2023321595458Open ↗
08/08/2023321595458Open ↗
Showing 3 of 13 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
11/06/2024321595458Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
04/08/2020322034847Open ↗
▸Zoning, Tax Lot & Property Records7
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
06/20/2023322160326Open ↗
▸BISTAX LOT: FINAL LOT NUMBER ISSUED1
04/07/2025321595458Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
10/08/2020321595458Open ↗
▸BISVERIFY TAX LOT1
04/07/2025321595458Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
11/06/2024321595458Open ↗
▸BISZONING DIAGRAM1
10/08/2020321595458Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
10/08/2020321595458Open ↗
▸Seals & Professional Certifications35
▸DOB NOWDPL-1: Design Professional Seal & Signature19
08/27/2026B00863137-P1Open ↗
08/27/2026B00863137-I1Open ↗
08/27/2026B00861665-I1Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B00258517-P1Open ↗
08/29/2026B00257999-P3Open ↗
08/29/2026B00257999-P3Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
08/08/2023321595458Open ↗
06/14/2023321595458Open ↗
09/22/2022321595458Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026B00258517-P1Open ↗
08/29/2026B00257999-P3Open ↗
08/28/2026B00258517-I1Open ↗
Showing 3 of 5 on file for this type
▸Trade Schedules & Equipment9
▸DOB NOWFDNY: Letter of No Objection7
08/13/2026B00264599-I1Open ↗
08/13/2026B00264615-P3Open ↗
08/13/2026B00264615-P2Open ↗
Showing 3 of 7 on file for this type
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
11/07/2024321595458Open ↗
▸BIS* SEWER CONNECTION: DEP SD1 & SD21
08/14/2020321595458Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST2
03/26/2025321595458Open ↗
07/07/2020321595458Open ↗
▸BISSTREET TREE SIGNOFF1
03/25/2025321595458Open ↗
▸BISSTREET TREES SITE PLAN1
09/30/2020322034847Open ↗
▸Energy Compliance14
▸BISAIR SEALING AND INSULATION - VISUAL1
12/18/2024321595458Open ↗
▸BISINTERIOR LIGHTING POWER1
12/18/2024321595458Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
12/18/2024321595458Open ↗
▸BISFENESTRATION AREAS1
12/18/2024321595458Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/04/2020321595458Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
12/18/2024321595458Open ↗
▸BISLIGHTING IN DWELLING UNITS1
12/18/2024321595458Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
12/20/2024321595458Open ↗
▸BISLIGHTING CONTROLS1
12/18/2024321595458Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
12/20/2024321595458Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/09/2022321595458Open ↗
▸BISELECTRICAL ENERGY CONSUMPTION1
12/18/2024321595458Open ↗
▸BISEXTERIOR LIGHTING POWER1
12/18/2024321595458Open ↗
▸BISFENESTRATION AIR LEAKAGE1
12/18/2024321595458Open ↗
▸Inspections & Test Reports21
▸BISTECHNICAL REPORT: RESPONSIBILITY6
01/05/2025321595458Open ↗
01/02/2025321595458Open ↗
01/02/2025321595458Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: SOIL INSPECTION2
10/08/2020321595458Open ↗
09/04/2020321595458Open ↗
▸BISSUBSURFACE / SOILS-FILL PLACEMENT IN-PLACE DENSITY1
05/01/2023321595458Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
05/01/2023321595458Open ↗
▸BISTR2: CONCRETE FIELD TESTING TECHNICAL REPORT1
04/10/2025321595458Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
01/03/2025321595458Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
12/20/2024321595458Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
12/20/2024321595458Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
05/01/2023321595458Open ↗
▸BISSPRAYED FIRE-RESISTANT MATERIALS1
12/20/2024321595458Open ↗
▸BISSUBGRADE INSP / SOILS-SITE PREP1
05/01/2023321595458Open ↗
▸BISSOIL REPORT1
10/08/2020321595458Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
06/09/2022321595458Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
06/09/2022321595458Open ↗
▸BISDEMOLITION (DM) JOB SIGNOFF1
11/06/2024321595458Open ↗
▸Approvals, Objections & Sign-offs9
▸BISSCHEDULE A - OCCUPANCY / USE3
11/15/2024321595458Open ↗
11/14/2022321595458Open ↗
07/07/2020321595458Open ↗
▸BISSUPERSEDING LETTER3
08/08/2023321595458Open ↗
06/14/2023321595458Open ↗
09/22/2022321595458Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
02/08/2024321595458Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM (SIGNOFF)1
02/19/2025321595458Open ↗
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
12/09/2024322034847Open ↗
▸Cost, Insurance & Ownership6
▸BISPROJECT-SPECIFIC GL INSURANCE5
02/08/2024321595458Open ↗
06/14/2023321595458Open ↗
12/29/2022321595458Open ↗
Showing 3 of 5 on file for this type
▸BISAcord 25 (Acord Certificate of Liability Insurance)1
09/22/2022321595458Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET4
06/05/2023322160326Open ↗
06/24/2020321595458Open ↗
06/24/2020321595458Open ↗
Showing 3 of 4 on file for this type
▸Other Documents9
▸BISBPP - SUPPORTING DOCUMENTATION2
11/05/2020322034847Open ↗
04/08/2020322034847Open ↗
▸BISPLOT DIAGRAM2
10/08/2020321595458Open ↗
09/04/2020321595458Open ↗
▸BISUNDERPINNING (2014)2
12/20/2024321595458Open ↗
12/20/2024321595458Open ↗
▸BISLOCAL LAW - SUPPPORTING DOCUMENTATION1
10/08/2020321595458Open ↗
▸BISPROTECTION OF EXPOSED FOUNDATION INSULATION1
10/02/2024321595458Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
04/07/2025321595458Open ↗