← Back
Two family converted from one family
28 ST FELIX STREET
BROOKLYN · Fort Greene · BIN 3058673
💬 Discuss this project
1900Year Built
2Stories
B3Building Class
R6BZoning
1,890 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · Owner of record: THE FELIX STANDARD LLC · 1,188 sf lot · 1.59 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction21p · 1 filing · 16 docs
Floor 3Under Construction29p · 2 filings · 20 docs
Floor 2Under Construction28p · 2 filings · 20 docs
Floor 1Under Construction28p · 2 filings · 20 docs
CellarUnder Construction28p · 2 filings · 20 docs
Sub-BasementUnder Construction28p · 2 filings · 20 docs
Site & exteriorUnder Construction20p · 1 filing · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
28 SAINT FELIX208/28/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/29/2022$890K—Private party → THE FELIX STANDARD LLC$471/sf building
11/29/2022$583K—Private party → THE FELIX STANDARD LLC$309/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HAMANN ENGINEERING, PLLC506/11/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BIG ORANGE EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DLM CONTRACTORS INCGeneral Contractor403/21/2026
CEL SERVICES INCGeneral Contractor307/10/2026
NOPHIER PLUMBING & HTG INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HAMANN ENGINEERING, PLLC4949406/11/2026
Building Lifecycle
All (74)Filed (5)Permit Issued (6)Violation (1)Inspection (1)Objection (32)Special Inspection (29)
08/26/2026
Objection raised — Structural
08/26/2026
Objection raised — Fire_Protection
08/26/2026
Objection raised — Zoning
08/26/2026
Objection raised — Scope
08/26/2026
Objection raised — Other
08/26/2026
Objection raised — Other
08/26/2026
Objection raised — Scope
08/26/2026
Objection raised — Structural
08/05/2026
Objection resolved — Addressed
08/05/2026
Objection resolved — Addressed
08/05/2026
Objection resolved — Open
08/05/2026
Objection resolved — Open
08/05/2026
Objection resolved — Addressed
08/05/2026
Objection resolved — Open
08/05/2026
Objection resolved — Open
08/05/2026
Objection resolved — Open
07/09/2026
Permit issued — Mechanical Systems
B00827020-S2-MS
06/23/2026
Objection raised — Scope
06/23/2026
Objection raised — Admin
06/23/2026
Objection raised — Admin
06/23/2026
Objection raised — Scope
06/23/2026
Objection raised — Scope
06/23/2026
Objection raised — Other
06/23/2026
Objection raised — Cost
06/23/2026
Objection raised — Other
06/17/2026
Objection resolved — Addressed
06/17/2026
Objection resolved — Addressed
06/17/2026
Objection resolved — Addressed
06/17/2026
Objection resolved — Addressed
06/12/2026
Objection raised — Zoning
06/12/2026
Objection raised — Accessibility
06/12/2026
Objection raised — Inspections
06/12/2026
Objection raised — Scope
06/11/2026
Filed — Alteration
MECHANICAL WORK AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
B00827020-S2
06/04/2026
Filed — Alteration
MECHANICAL WORK AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
B00827020-S1
05/20/2026
Special inspection requirement — Concrete - Cast-In-Place
05/20/2026
Special inspection requirement — Lighting in dwelling units
05/20/2026
Special inspection requirement — Air barrier - visual inspection
05/20/2026
Special inspection requirement — Insulation placement and R values
05/20/2026
Special inspection requirement — Fenestration areas
05/20/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
05/20/2026
Special inspection requirement — Fenestration air leakage
05/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
05/20/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/20/2026
Special inspection requirement — Structural Cold-Formed Steel
05/13/2026
Special inspection requirement — Final
03/31/2026
Special inspection requirement — HVAC-R and service water heating system controls
CARL HAMANN
03/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CARL HAMANN
03/31/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CARL HAMANN
03/31/2026
Special inspection requirement — HVAC-R and service water heating equipment
CARL HAMANN
03/31/2026
Special inspection requirement — Maintenance information
CARL HAMANN
03/27/2026
Filed — Alteration
PLUMBING WORK AS PER PLAND FILED HEREWITH. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
B00846011-P1
03/26/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/18/2026
Permit issued — Plumbing
B00846011-I1-PL
03/02/2026
Permit issued — Mechanical Systems
B00827020-I1-GC
02/12/2026
Permit issued — Mechanical Systems
B00827020-I1-GC
03/04/2025
Permit issued — General Construction
B00827020-I1-GC
08/02/2024
Permit issued — General Construction
B00827020-I1-GC
03/08/2024
Filed — Alteration
MECHANICAL WORK AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
B00827020-I1
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedCEL SERVICES INC07/09/2026
DOB NOWPlumbingPermit IssuedNOPHIER PLUMBING & HTG IN03/18/2026
DOB NOWMechanical SystemsPermit IssuedCEL SERVICES03/02/2026
DOB NOWMechanical SystemsPermit IssuedCEL SERVICES02/12/2026
DOB NOWGeneral ConstructionPermit IssuedDLM CONTRACTORS03/04/2025
DOB NOWGeneral ConstructionPermit IssuedDLM CONTRACTORS08/02/2024
1 project · most recent 06/11/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/11/2026Permit IssuedCEL SERVICES INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-5836NA 36,000 BTU · Condensing Unit ×1
MXZ-5842NA 42,000 BTU · Vrf Outdoor ×1
1 project · most recent 03/27/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/27/2026Permit IssuedNOPHIER PLUMBING & HTG INGas, Storm, Water/Sanitary
1 project · most recent 03/13/2023
General Wiring
FiledStatusContractorScope
03/13/2023Permit IssuedCEL SVCS INC DBA CEL ELECGeneral Wiring
1 project · most recent 06/11/2026
Concrete
FiledStatusContractorScope
06/11/2026Permit IssuedCEL SERVICES INCConcrete
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
03/26/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
05/20/2026Concrete - Cast-In-Place—special
05/20/2026Lighting in dwelling units—energy_progress
05/20/2026Air barrier - visual inspection—energy_progress
05/20/2026Insulation placement and R values—energy_progress
05/20/2026Fenestration areas—energy_progress
05/20/2026Fenestration and door U-factor and product ratings—energy_progress
05/20/2026Fenestration air leakage—energy_progress
05/20/2026Fire-Resistance Rated Construction—progress
05/20/2026Structural Stability – Alterations of existing buildings—special
05/20/2026Fire-Resistant Penetrations and Joints—special
05/20/2026Structural Cold-Formed Steel—special
05/13/2026Final—progress
03/31/2026HVAC-R and service water heating system controlsCARL HAMANNenergy_progress
03/31/2026Fire-Resistant Penetrations and JointsCARL HAMANNspecial
03/31/2026HVAC-R and service water piping design and insulationCARL HAMANNenergy_progress
03/31/2026HVAC-R and service water heating equipmentCARL HAMANNenergy_progress
03/31/2026Maintenance informationCARL HAMANNenergy_progress
03/08/2024Insulation placement and R valuesCARL HAMANNenergy_progress
08/03/2023Fenestration air leakageCARL HAMANNenergy_progress
08/03/2023Fire-Resistance Rated ConstructionCARL HAMANNprogress
08/03/2023Energy Code Compliance InspectionsCARL HAMANNprogress
08/03/2023Fire-Resistant Penetrations and JointsCARL HAMANNspecial
08/03/2023Concrete - Cast-In-PlaceCARL HAMANNspecial
08/03/2023Fenestration areasCARL HAMANNenergy_progress
08/03/2023Interior lighting powerCARL HAMANNenergy_progress
Latest 25 of 29.
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/17/2026B00846011-I1Request digital key ↗
08/17/2026B00846011-P1Request digital key ↗
08/16/2026B00827020-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 13
08/13/2026B00846011-I1Open ↗
08/13/2026B00827020-I1Open ↗
08/13/2026B00846011-P1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026B00827020-S1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026B00846011-P1Open ↗
08/17/2026B00846011-I1Open ↗
08/16/2026B00827020-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/30/2026B00846011-I1Open ↗
08/26/2026B00827020-I1Open ↗
08/26/2026B00827020-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026B00846011-I1Open ↗
08/26/2026B00827020-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/17/2026B00846011-P1Open ↗
08/17/2026B00846011-I1Open ↗
08/14/2026B00827020-S2Open ↗
Showing 3 of 5 on file for this type
▸Other Documents2
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/14/2026B00827020-S1Open ↗
▸DOB NOWSite Survey: Initial1