← Back
Two family brick
283 CARROLL STREET
BROOKLYN · BIN 3007432
💬 Discuss this project
1874Year Built
3Stories
B1Building Class
R6BZoning
3,120 sfGross Floor Area
2Units
Rent Stabilized0 Open Violations
Two family brick · Owner of record: PATTERN HOUSE CARROLL STREET TRUST · 1,957 sf lot · 1.59 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction18p · 1 filing · 20 docs
Floor 2Under Construction5p · 2 filings · 20 docs
Floor 1Under Construction6p · 2 filings · 20 docs
Sub-BasementUnder Construction15p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/10/2024$5.2M—Private party → Private party$1,683/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CODE603/21/2026
B A INSPECTIONS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SP CONTRACTORS OF NY INCGeneral Contractor403/21/2026
GRANT DAVIS THOMPSON INCGeneral Contractor307/08/2026
SP CONTRACTORS OF NY, INCPlumbing307/08/2026
ASPECT PLBNG&HTNG CO LLCPlumbing208/14/2026
PALONE BROTHERS AIRGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BAALBAKI&ASSOCIATES ENGIN1858808/06/2026
STRUCTURAL CONSULTING SER1919105/26/2022
Building Lifecycle
All (94)Filed (11)Permit Issued (11)Signed Off (4)Violation (16)Inspection (8)Objection (28)Special Inspection (16)
08/21/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/13/2026
Permit issued — Plumbing
B01222981-S5-PL
08/12/2026
Special inspection requirement — Mechanical Systems
Mohammad Baalbaki
08/12/2026
Special inspection requirement — Final
Barry Berg
08/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/06/2026
Filed — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-S5
08/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Mohammad Baalbaki
07/28/2026
Objection resolved — Addressed
07/28/2026
Objection resolved — Addressed
07/28/2026
Objection resolved — Addressed
07/28/2026
Objection resolved — Addressed
07/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/27/2026
Objection raised — Inspection report required for
07/27/2026
Objection raised — Scope
07/27/2026
Objection raised — Scope
07/27/2026
Objection raised — Scope
07/15/2026
Objection resolved — Addressed
07/13/2026
Objection raised — Scope
07/08/2026
Filed — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-P3
07/08/2026
Special inspection requirement — Final
Barry Berg
07/08/2026
Special inspection requirement — Mechanical Systems
Mohammad Baalbaki
07/01/2026
Filed — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-P2
07/01/2026
Objection resolved — Resolved
06/23/2026
Permit issued — General Construction
B01222981-I1-GC
06/22/2026
Signed off — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-S3
06/18/2026
Objection resolved — Addressed
06/11/2026
Objection raised — Scope
06/11/2026
Objection raised — Scope
05/21/2026
Filed — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-P1
03/31/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/31/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/01/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/08/2025
Permit issued — Plumbing
B01222981-S2-PL
08/18/2025
Objection resolved — Addressed
08/11/2025
Objection raised — Admin
07/28/2025
Objection resolved — Addressed
07/24/2025
Objection raised — Other
07/23/2025
Permit issued — Mechanical Systems
B01222981-S4-MS
07/17/2025
Permit issued — Structural
B01222981-S3-ST
07/15/2025
Objection resolved — Addressed
07/14/2025
Objection raised — Cost
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
06/30/2025
Filed — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-S4
06/25/2025
Objection resolved — Addressed
06/24/2025
Objection raised — Scope
06/24/2025
Objection raised — Cost
06/23/2025
Permit issued — General Construction
B01222981-I1-GC
06/14/2025
Filed — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-S3
06/13/2025
Special inspection requirement — Structural Steel - Details
Mohammad Baalbaki
06/13/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Mohammad Baalbaki
06/13/2025
Special inspection requirement — Final
Barry Berg
06/11/2025
Objection raised — Plumbing
06/11/2025
Objection raised — Plumbing
05/31/2025
Filed — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-I1
05/31/2025
Filed — Alteration
INSTALL AND REPLACE SPLIT UNITS
B01222981-S2
04/09/2024
Violation issued (HPD, closed)
A
11/22/2023
Violation issued (HPD, closed)
I
10/13/2023
Signed off — Alteration
Installation and modification of plumbing fixtures at existing residence on floor 002. Plumbing work. There is to be no change of use, occupancy, or egress.
B00712165-I1
Latest 60 of 94 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedASPECT PLBNG&HTNG CO LLC08/13/2026
DOB NOWGeneral ConstructionPermit IssuedGRANT DAVIS THOMPSON INC06/23/2026
DOB NOWPlumbingSigned-offASPECT PLBNG&HTNG CO LLC09/08/2025
DOB NOWMechanical SystemsPermit IssuedPALONE BROTHERS AIR07/23/2025
DOB NOWStructuralSigned-offGRANT DAVIS THOMPSON INC07/17/2025
DOB NOWGeneral ConstructionPermit IssuedGRANT DAVIS THOMPSON INC06/23/2025
DOB NOWPlumbingSigned-offSP CONTRACTORS OF NY, INC09/12/2023
DOB NOWPlumbingSigned-offSP CONTRACTORS OF NY, INC06/22/2023
DOB NOWStructuralSigned-offSP CONTRACTORS OF NY INC06/13/2022
DOB NOWGeneral ConstructionSigned-offSP CONTRACTORS OF NY INC06/13/2022
DOB NOWPlumbingSigned-offSP CONTRACTORS OF NY, INC06/13/2022
BIS—ISSUEDJ.MATURA ASSOCIATES INC02/05/2013
BISOTISSUEDJ.MATURA ASSOCIATES INC11/14/2012
BISMHISSUEDJ.MATURA ASSOCIATES INC03/15/2012
BISPLISSUEDBYPASS MECHANICAL CORP01/30/2012
BIS—ISSUEDJ.MATURA ASSOCIATES INC01/26/2012
BISOTISSUEDB & H RESTORATION INC11/03/2011
BISOTISSUEDB & H RESTORATION INC09/27/2011
1 job · most recent 08/06/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/06/2026Permit IssuedGRANT DAVIS THOMPSON INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-3C24NA4--Basement 24,000 BTU · Condensing Unit ×2
MXZ-4C36NA4--1st floor 36,000 BTU · Condensing Unit ×2
SM60NAM2--2&3 floors 60,000 BTU · Condensing Unit ×2
Ventilation
Ventilation Direct gbr-80 80 CFM ×2
1 job · most recent 08/06/2026
Gas Water/Sanitary
FiledStatusContractorScope
08/06/2026Permit IssuedASPECT PLBNG&HTNG CO LLCGas, Water/Sanitary
1 job · most recent 07/29/2025
General Wiring
FiledStatusContractorScope
07/29/2025Permit IssuedSTABILITY ELEC ENTERP INCGeneral Wiring
1 job · most recent 08/06/2026
Steel
FiledStatusContractorScope
08/06/2026Permit IssuedASPECT PLBNG&HTNG CO LLCSteel
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
08/21/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/31/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/31/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/01/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/02/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/21/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/25/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/24/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
08/12/2026Mechanical SystemsMohammad Baalbakispecial
08/12/2026FinalBarry Bergprogress
08/12/2026Fire-Resistant Penetrations and Joints—special
08/06/2026Fire-Resistant Penetrations and JointsMohammad Baalbakispecial
07/28/2026Fire-Resistant Penetrations and Joints—special
07/08/2026FinalBarry Bergprogress
07/08/2026Mechanical SystemsMohammad Baalbakispecial
06/13/2025Structural Steel - DetailsMohammad Baalbakispecial
06/13/2025Structural Stability – Alterations of existing buildingsMohammad Baalbakispecial
06/13/2025FinalBarry Bergprogress
05/03/2022Structural Stability – Alterations of existing buildingsAndrew McConnellspecial
05/03/2022Structural Steel - DetailsAndrew McConnellspecial
05/03/2022Concrete - Cast-In-PlaceAndrew McConnellspecial
04/21/2022Fire-Resistance Rated ConstructionGABRIELLE MARCOUXprogress
04/04/2022FinalAndrew McConnellprogress
04/04/2022FinalGABRIELLE MARCOUXprogress
▾Documents — 125 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/29/2026B00712162-I1Request digital key ↗
08/29/2026B00712165-I1Request digital key ↗
08/29/2026B00712169-I1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits25
▸DOB NOWLPC Approval/Permit11
08/16/2026B01222981-S5Open ↗
08/15/2026B01222981-P3Open ↗
08/15/2026B01222981-P2Open ↗
Showing 3 of 11 on file for this type
▸BISWORK PERMIT APPLICATION8
02/06/2013320378088Open ↗
11/15/2012320350124Open ↗
03/19/2012320428845Open ↗
Showing 3 of 8 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
12/18/2013320378088Open ↗
02/13/2012320428845Open ↗
01/17/2012320378088Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY APPLICATION2
12/13/2013320378088Open ↗
05/21/2012320378088Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISADDRESS - NEW HOUSE NUMBER APPROVED1
01/26/2012320378088Open ↗
▸Seals & Professional Certifications32
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/16/2026B01222981-S3Open ↗
08/16/2026B01222981-S5Open ↗
08/16/2026B01222981-P3Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/23/2026B01222981-S4Open ↗
09/04/2026B01222981-S3Open ↗
09/04/2026B01222981-S3Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
06/21/2014320350124Open ↗
08/15/2012320428845Open ↗
03/19/2012320428845Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026B01222981-S4Open ↗
09/04/2026B01222981-S3Open ↗
08/31/2026B01222981-P3Open ↗
Showing 3 of 6 on file for this type
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING2
01/26/2012320378088Open ↗
10/15/2011320378088Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
10/15/2011320378088Open ↗
▸Environmental & Asbestos15
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/16/2026B01222981-S3Open ↗
08/16/2026B01222981-S5Open ↗
08/16/2026B01222981-S4Open ↗
Showing 3 of 11 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'4
02/13/2012320428845Open ↗
10/15/2011320378088Open ↗
09/12/2011320350124Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance6
▸BISTR8: Energy Code Progress Inspections2
12/30/2013320378088Open ↗
01/26/2012320378088Open ↗
▸BISTECHNICAL REPORT: ENERGY2
02/13/2012320428845Open ↗
10/15/2011320378088Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/15/2012320428845Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
08/15/2012320428845Open ↗
▸Approvals, Objections & Sign-offs16
▸BISLETTERS - SUPPORTING DOCUMENTATION8
06/05/2014320378088Open ↗
12/18/2013320378088Open ↗
12/13/2013320378088Open ↗
Showing 3 of 8 on file for this type
▸BISLANDMARKS APPROVAL3
06/21/2014320350124Open ↗
02/13/2012320428845Open ↗
01/26/2012320378088Open ↗
▸BISADMINISTRATIVE OBJECTIONS3
02/13/2012320428845Open ↗
10/15/2011320378088Open ↗
09/12/2011320350124Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/15/2012320428845Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
01/17/2012320378088Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
08/15/2012320428845Open ↗
02/13/2012320428845Open ↗
10/15/2011320378088Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms9
▸BISADDITIONAL INFORMATION6
06/05/2014320378088Open ↗
06/05/2014320378088Open ↗
12/27/2013320378088Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET3
02/13/2012320428845Open ↗
10/15/2011320378088Open ↗
09/12/2011320350124Open ↗
▸Other Documents3
▸DOB NOWProof of Historic Building2
08/13/2026B00712162-I1Open ↗
08/13/2026B00712165-I1Open ↗
▸BISPlot Diagram1
10/15/2011320378088Open ↗