ECB08/06/2026ATOI OBSERVED WORKERS DEMOLISHING CONCRETE SLAB IN VIOLATION OF PARTIAL STOP WORK ORDER 1719912 ISSUED ON 04/03/2026., COMPLY WITH STOP WORK ORDER$10K due
DOB04/03/2026FAILURE TO MAINTAIN BLDG IN CODE COMPLAINCE MANNER.2 STORY PARKING GAR AGE CONSISTING OF BSMT AND 1 FL HAS A PARTIAL COLLAPSE OCCURED ON 3/16 /26
DOB04/03/2026FAILURE TOMAINTAIN BLDG IN CODE COMPLIANT MANNER. A TWO STORIES PARKIN G GARAGE CONSISTING OF BSMT 1FL LEVEL HAS A PARTIAL COLLAPSE OCURRED ON 3/16/26 AS ONE STEEL FILLER BEAM ON THE FIRST LEVEL COLLAPSED ALONG WITH A PORTION OG THE ADJOINING SLAB ON THE BSMT SLAB ON GRADE. REMED Y OWNER TO RETAIN NYSPE TO EVALUATE THE ENTIRE P.S. AND FILE DRAWING
ECB03/18/2026FAILURE TO SAFEGUARD THIS PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. AS NOTED AT TIME OF INSPECTION BASE ON COMPLAINT #1719698 SAYS BUILDING PARTIALLY COLLAPSED AND REVEAL BEAMS SHOWN SIGNS OF COLA$25K due
ECB03/18/2026FAILURE TO MAINTAIN/DISPLAY SITE DOCUMENTS REQUIRED CHAPTER 33: AS NOTED AT TIME OF INSPECTION ON A COMPLAINT #1719698 OBSERVED ON ENQUIRINGFOR RESHORING DOCUMENTS AND FOR THE DEMOLISHING SEQUENCE FOR REMOVING$12K due
DOB05/02/2024FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB06/01/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/02/2022FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB12/01/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB11/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB06/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB04/29/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB02/02/2021FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB11/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB02/02/2020FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB11/02/2019FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB08/02/2019FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2019FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
ECB01/13/2024FAILURE TO MAINTAIN BUILDING CODE COMPLIANT. NOTED: THERE IS SPALLING AND MISSING CONCRETE EXPOSING RE-BAR AND STEEL I-BEAMS AT VARIOUS AREAS OF THE FIRST FLOOR GARAGE CEILING., REPAIR AND/OR REPLACE; COMPLY WINothing owed — awaiting certificate of correction
ECB03/24/2014FAILURE TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS ENCLOSURES/CABLE ARMOUR.SEAL TIGHT FEEDING MOTOR FOR ROLL DOWN GATE NOT PROPERLY TERMINATED.REM:PROVIDE EFFECTIVE ELECTRICAL CONTINUITYNothing owed — awaiting certificate of correction
ECB11/28/2005FAILURE TO POST THE "C OF O" REMEDY: POST THE "C OF O" AT THE SITE.Nothing owed — awaiting certificate of correction
ECB07/29/1997WORK WITHOUT A PERMIT: UPON INSPECTION AT ABOVE PREMISES PLUMBING WORKWAS DONE CONSIST OF REMOVING BATHROOM FIXTURES DEPT. RECORD SHOW NO PERMIT WAS ISSUED FOR SAID WORK. REMEDY: OBTAIN PERMIT FOR SAID WORK FRONothing owed — awaiting certificate of correction
ECB07/29/1997WORK WITHOUT PERMIT. ALTERATION WORK WAS DONE AT SAID LOCATION PARTITIONS WALLS HAS BEEN REMOVED FROM BATH ROOM AREA ENCLOSING CHASE WALL. DEPT. RECORD SHOW NO PERMIT WAS ISSUED FOR SAID WORK. REMEDY: OBTAINNothing owed — awaiting certificate of correction