← Back
Elevator apt, fireproof without stores
285 EAST 163 STREET
BRONX · Concourse-Concourse Village · BIN 2129676
💬 Discuss this project
2022Year Built
6Stories
D3Building Class
R7-1Zoning
24,502 sfGross Floor Area
36Units
Rent Stabilized0 Open Violations
Elevator apt, fireproof without stores · Owner of record: 285E163RDNY LLC · 7,125 sf lot · 3.44 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingFire Protection
Roof4p · 4 filings · 20 docs
Floor 64p · 3 filings · 19 docs
Floor 51p · 1 filing · 3 docs
Floor 41p · 1 filing · 3 docs
Floor 31p · 1 filing · 3 docs
Floor 22p · 2 filings · 14 docs
Floor 13p · 3 filings · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GP RESTORATION NYC INC.503/22/2026
285E163RDNY LLC503/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/16/2020$1.6M—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COBBLE COURT ENGINEERING105/28/2024
MOSTAFA204/11/2024
PAUL G. JONES, P.E.110/21/2022
ANTHONY CUCICH ARCHITECT611/16/2021
SYED ENGINEERING, P.C.106/02/2021
CNY ENGINEERING P.C205/27/2021
SD DESIGN STUDIO LLC102/01/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ANTHONY CUCICH ARCHITECT603/21/2026
CNY ENGINEERING PC203/21/2026
CONSOLIDATED SCAFFOLD BRIDGE403/21/2026
PEREXPERTS GMAIL COM203/21/2026
QUEST HOME IMPROVEMENT103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW LINE CONSTRUCTION LLCGeneral Contractor1107/08/2026
CONSOLIDATED SCAFFOLDINGGeneral Contractor907/08/2026
H20 LLCGeneral Contractor303/21/2026
QUEST HOME IMPROVEMENT INGeneral Contractor303/21/2026
PRIME PIPING & HEATING INFire Protection207/08/2026
LLOYD G DRUMMOND PLBG&GENPlumbing107/08/2026
MANUEL MEROElectrical103/21/2026
LLOYD G DRUMMOND PLBG&GENFire Protection107/08/2026
DENNISON ELECTRIC CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272105/28/2024
ANTHONY CUCICH ARCHITECT6081504/11/2024
CNY ENGINEERING P.C3304205/27/2021
Building Lifecycle
All (129)Filed (14)Permit Issued (18)Signed Off (11)Violation (8)Inspection (12)Objection (54)Special Inspection (12)
02/10/2026
Violation issued (HPD, closed)
C
02/10/2026
Violation issued (HPD, closed)
C
01/20/2026
Violation issued (HPD, closed)
A
06/16/2025
Violation issued (HPD, closed)
A
06/28/2024
Signed off — Alteration
X01055395-I1
05/30/2024
Permit issued — Solar
X01055395-I1-SL
05/28/2024
Filed — Alteration
X01055395-I1
05/03/2024
Signed off — Alteration
PROPOSED 10'-0'' CURB CUT.
X00458488-I1
05/02/2024
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
04/24/2024
Signed off — Alteration
Structural job in conjunction with NB BIS Job #240300535
X00579992-I1
04/19/2024
Special inspection requirement — Structural Cold-Formed Steel
ANTHONY CUCICH
04/19/2024
Special inspection requirement — Masonry
ANTHONY CUCICH
04/19/2024
Special inspection requirement — Footing and Foundation
ANTHONY CUCICH
04/19/2024
Special inspection requirement — Final
ANTHONY CUCICH
04/11/2024
Filed — Alteration
Structural job in conjunction with NB BIS Job #240300535
X00579992-P1
04/11/2024
Special inspection requirement — Footing and Foundation
ANTHONY CUCICH
04/11/2024
Special inspection requirement — Masonry
ANTHONY CUCICH
04/11/2024
Special inspection requirement — Structural Cold-Formed Steel
ANTHONY CUCICH
04/11/2024
Special inspection requirement — Final
ANTHONY CUCICH
04/01/2024
Signed off — Alteration
INSTALL NEW STANDPIPE SYSTEM FOR NEW 6-STORY BUILDING IN CONJUNCTION WITH NB JOB#240300535. SPRINKLER APPLICATION FILED SEPARATELY UNDER DOB NOW#X00458032.NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00498453-I1
04/01/2024
Signed off — Alteration
INSTALL NEW STANDPIPE SYSTEM FOR NEW 6-STORY BUILDING IN CONJUNCTION WITH NB JOB#240300535. SPRINKLER APPLICATION FILED SEPARATELY UNDER DOB NOW#X00458032.NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00498453-S1
03/28/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/12/2024
Inspection — Certified StandPipe-Fire Pump (SD)-Fire Pump Test
Certified
View inspection ↗
02/23/2024
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
02/20/2024
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
02/08/2024
Signed off — Alteration
X00463009-I1
01/26/2024
Signed off — Alteration
X00457427-I1
01/26/2024
Signed off — Alteration
PROPOSE TO INSTALL SPRINKLER SYSTEM AND SERVICE CONNECTION TO WATER MAIN AS PER PLAN. FILED IN CONJUNCTION WITH APPLICATION #240300535.
X00458032-I1
12/11/2023
Permit issued — General Construction
X00579992-I1-GC-CX
12/08/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
12/05/2023
Signed off — Alteration
TEMPORARY INSTALLATION OF A PIPE SCAFFOLD AS PER DRAWINGS DURING GENERAL CONSTRUCTION WORK . NO CHANGE IN USE, EGRESS, AND OCCUPANCY. PIPE SCAFFOLD TO COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE OF 2014.
X00531820-S1
12/05/2023
Signed off — Alteration
TEMPORARY INSTALLATION OF A PIPE SCAFFOLD AS PER DRAWINGS DURING GENERAL CONSTRUCTION WORK . NO CHANGE IN USE, EGRESS, AND OCCUPANCY. PIPE SCAFFOLD TO COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE OF 2014.
X00531820-I1
10/24/2023
Signed off — Alteration
X00497853-I1
09/15/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/11/2023
Permit issued — Supported Scaffold
X00531820-S1-SF
06/23/2023
Permit issued — Curb Cut
X00458488-I1-CC
06/06/2023
Permit issued — Sidewalk Shed
X00531820-I1-SH
05/08/2023
Inspection — Certified StandPipe - SD - Alarm Sys 64/09 - Finish
Certified
View inspection ↗
05/08/2023
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
04/28/2023
Permit issued — Standpipe
X00498453-S1-EW-SD
04/28/2023
Permit issued — Standpipe
X00498453-I1-EW-SD
04/13/2023
Violation issued (ECB, closed)
Construction
04/13/2023
Violation issued (ECB, closed)
Construction
04/13/2023
Violation issued (ECB, closed)
Construction
03/06/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/15/2022
Permit issued — Mechanical Systems
X00463009-I1-MS
11/03/2022
Permit issued — Sprinklers
X00458032-I1-EW-SP
11/01/2022
Permit issued — Construction Fence
X00497853-I1-FN
11/01/2022
Permit issued — Foundation
X00579992-I1-GC-CX
10/21/2022
Filed — Alteration
TEMPORARY INSTALLATION OF A PIPE SCAFFOLD AS PER DRAWINGS DURING GENERAL CONSTRUCTION WORK . NO CHANGE IN USE, EGRESS, AND OCCUPANCY. PIPE SCAFFOLD TO COMPLY WITH CHAPTER 33 OF THE NYC BUILDING CODE OF 2014.
X00531820-S1
10/21/2022
Permit issued — Supported Scaffold
X00531820-S1-SF
06/21/2022
Permit issued — Construction Fence
X00497853-I1-FN
06/08/2022
Permit issued — Sidewalk Shed
X00531820-I1-SH
06/06/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/06/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/04/2022
Permit issued — Plumbing
X00457427-I1-PL
04/04/2022
Permit issued — General Construction
X00579992-I1-GC-CX
11/16/2021
Filed — Alteration
PROPOSED 10'-0'' CURB CUT.
X00458488-P1
09/16/2021
Objection raised — Energy
09/16/2021
Objection resolved — Addressed
Latest 60 of 129 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offQUEST HOME IMPROVEMENT IN05/30/2024
DOB NOWGeneral ConstructionSigned-offNEW LINE CONSTRUCTION LLC12/11/2023
DOB NOWSupported ScaffoldSigned-offCONSOLIDATED SCAFFOLDING07/11/2023
DOB NOWCurb CutSigned-offNEW LINE CONSTRUCTION LLC06/23/2023
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING06/06/2023
DOB NOWStandpipeSigned-offA M B MECHANICAL INC04/28/2023
DOB NOWStandpipeSigned-offA M B MECHANICAL INC04/28/2023
DOB NOWMechanical SystemsSigned-offNEW LINE CONSTRUCTION LLC12/15/2022
DOB NOWSprinklersSigned-offLLOYD G. DRUMMOND11/03/2022
DOB NOWConstruction FenceSigned-offNEW LINE CONSTRUCTION LLC11/01/2022
DOB NOWFoundationSigned-offNEW LINE CONSTRUCTION LLC11/01/2022
DOB NOWSupported ScaffoldSigned-offCONSOLIDATED SCAFFOLDING10/21/2022
DOB NOWConstruction FenceSigned-offNEW LINE CONSTRUCTION LLC06/21/2022
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING06/08/2022
DOB NOWPlumbingSigned-offLLOYD G DRUMMOND PLBG&GEN05/04/2022
DOB NOWGeneral ConstructionSigned-offNEW LINE CONSTRUCTION LLC04/04/2022
DOB NOWConstruction FenceSigned-offH20 LLC07/16/2021
DOB NOWSidewalk ShedSigned-offCONSOLIDATED SCAFFOLDING06/03/2021
4 projects · most recent 05/28/2024
General Wiring
FiledStatusContractorScope
05/28/2024CompleteLUNA NYC ELECTRIC CORP—
12/07/2023CompleteDENNISON ELECTRIC CORPGeneral Wiring
09/08/2022CompleteJAM ELECTRICAL CORP—
06/02/2021CompleteV. VASS ELECTRIC CORP—
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
05/02/2024Pass-Final Curb Cut Non-Directive 14PassView ↗
03/28/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/12/2024Certified StandPipe-Fire Pump (SD)-Fire Pump TestCertifiedView ↗
02/23/2024Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
02/20/2024Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
12/08/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/15/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/08/2023Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
05/08/2023Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
03/06/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/06/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/06/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
04/19/2024Structural Cold-Formed SteelANTHONY CUCICHspecial
04/19/2024MasonryANTHONY CUCICHspecial
04/19/2024Footing and FoundationANTHONY CUCICHprogress
04/19/2024FinalANTHONY CUCICHprogress
04/11/2024Footing and FoundationANTHONY CUCICHprogress
04/11/2024MasonryANTHONY CUCICHspecial
04/11/2024Structural Cold-Formed SteelANTHONY CUCICHspecial
04/11/2024FinalANTHONY CUCICHprogress
05/11/2021Standpipe SystemsYUE ZHOUspecial
02/08/2021Fire-Resistant Penetrations and JointsANTHONY CUCICHspecial
02/08/2021Energy Code Compliance InspectionsANTHONY CUCICHprogress
01/21/2021Sprinkler SystemsANTHONY CUCICHspecial
▾Documents — 129 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch8
08/25/2026X00497853-I1Request digital key ↗
08/25/2026X00531820-I1Request digital key ↗
08/25/2026X00531820-S1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Curb Cut2
08/25/2026X00458488-P1Request digital key ↗
08/14/2026X00458488-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/25/2026X00454305-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/25/2026X00457427-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/25/2026X00463009-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
08/25/2026X00458032-I1Request digital key ↗
▸Applications & Permits16
▸BISPLAN / WORK APPROVAL APPLICATION13
07/17/2024240300535Open ↗
05/29/2024240300535Open ↗
05/17/2024240300535Open ↗
Showing 3 of 13 on file for this type
▸BISWORK PERMIT APPLICATION2
02/16/2024240300535Open ↗
04/18/2022240300535Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
10/26/2023240300535Open ↗
▸Zoning, Tax Lot & Property Records6
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
04/07/2021240300535Open ↗
▸BISVERIFY TAX LOT1
01/30/2024240300535Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
08/16/2021240300535Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
05/01/2024240300535Open ↗
▸BISZONING DIAGRAM1
08/16/2021240300535Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
04/07/2021240300535Open ↗
▸Seals & Professional Certifications27
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/25/2026X00454305-I1Open ↗
08/25/2026X00457427-I1Open ↗
08/25/2026X00458488-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026X00458032-I1Open ↗
09/01/2026X00458032-I1Open ↗
08/26/2026X00579992-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026X00458032-I1Open ↗
08/26/2026X00579992-I1Open ↗
08/26/2026X00579992-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
04/13/2022240300535Open ↗
04/11/2022240300535Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
02/19/2021240300535Open ↗
▸Trade Schedules & Equipment1
▸BISDEP STORMWATER SEWER CERTIFICATION (HCP/SCP)1
05/03/2021240300535Open ↗
▸Safety & Tenant Protection7
▸BISSTREET TREE CHECKLIST3
08/16/2021240300535Open ↗
08/16/2021240300535Open ↗
02/19/2021240300535Open ↗
▸BISEXCAVATION - SHEETING, SHORING, AND BRACING1
03/29/2024240300535Open ↗
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
04/11/2022240300535Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
08/16/2021240300535Open ↗
▸BISSTREET TREE SIGNOFF1
02/01/2024240300535Open ↗
▸Energy Compliance15
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026X00463009-I1Open ↗
08/13/2026X00457427-I1Open ↗
▸BISFENESTRATION AIR LEAKAGE1
03/29/2024240300535Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
03/29/2024240300535Open ↗
▸BISINTERIOR LIGHTING POWER1
03/29/2024240300535Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
03/29/2024240300535Open ↗
▸BISFENESTRATION AREAS1
03/29/2024240300535Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
02/19/2021240300535Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
03/29/2024240300535Open ↗
▸BISLIGHTING IN DWELLING UNITS1
03/29/2024240300535Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
03/29/2024240300535Open ↗
▸BISELECTRIC MOTORS1
03/29/2024240300535Open ↗
▸BISLIGHTING CONTROLS1
03/29/2024240300535Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
03/15/2024240300535Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/11/2022240300535Open ↗
▸Inspections & Test Reports19
▸BISTR2: CONCRETE FIELD TESTING TECHNICAL REPORT2
07/17/2024240300535Open ↗
04/19/2024240300535Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX2
04/11/2022240300535Open ↗
04/11/2022240300535Open ↗
▸BISDEMOLITION (DM) JOB SIGNOFF1
02/12/2024240300535Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
03/29/2024240300535Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
04/12/2024240300535Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
03/29/2024240300535Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
03/29/2024240300535Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
03/29/2024240300535Open ↗
▸BISMASONRY1
03/29/2024240300535Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/16/2021240300535Open ↗
▸BISSUBGRADE INSP / SOILS-SITE PREP1
01/30/2024240300535Open ↗
▸BISSOIL REPORT1
02/19/2021240300535Open ↗
▸BISSOIL PERC. TEST-PVT ON-SITE STORM WATER DRAINAGE DISPOSAL SYS & DET. FACL.1
03/29/2024240300535Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
04/11/2022240300535Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
02/19/2021240300535Open ↗
▸BISSOIL PERC. TEST-INDIVID ON-SITE PRIVATE SEWAGE DISP.(SEPTIC)1
03/29/2024240300535Open ↗
▸BISMECHANICAL SYSTEMS1
03/29/2024240300535Open ↗
▸Approvals, Objections & Sign-offs8
▸BISSCHEDULE A - OCCUPANCY / USE6
07/17/2024240300535Open ↗
08/18/2021240300535Open ↗
05/13/2021240300535Open ↗
Showing 3 of 6 on file for this type
▸BISFINAL CONSTRUCTION SIGNOFF1
08/12/2024240300535Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01055395-I1Open ↗
▸Cost, Insurance & Ownership2
▸BISPROJECT-SPECIFIC GL INSURANCE2
02/16/2024240300535Open ↗
04/11/2022240300535Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
08/30/2021240300535Open ↗
08/16/2021240300535Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
02/19/2021240300535Open ↗
▸Other Documents9
▸BISSITE SURVEY: FINAL1
—240300535Open ↗
▸BISSITE SURVEY: INITIAL1
—240300535Open ↗
▸BISLOCAL LAW - SUPPPORTING DOCUMENTATION1
08/12/2024240300535Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
02/19/2021240300535Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
08/30/2021240300535Open ↗
▸BISMAINTENANCE INFORMATION1
03/29/2024240300535Open ↗
▸BISPROTECTION OF EXPOSED FOUNDATION INSULATION1
03/29/2024240300535Open ↗
▸BISPLOT DIAGRAM1
08/16/2021240300535Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026X00579992-I1Open ↗