← Back
Two family frame
286 17 STREET
BROOKLYN · BIN 3016756
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R6BZoning
1,710 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two family frame · 1,903 sf lot · 0.9 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TO THE OWNERS OF 286 17ST103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/14/2015$900K—Private party → Private party$526/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LAM ENGINEER PC209/30/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L2 CONSTRUCTION INCGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CHENG-SHENG HUANG3540209/30/2020
LAM ENGINEER PC1180209/30/2020
Building Lifecycle
All (14)Filed (2)Permit Issued (1)Signed Off (1)Violation (2)Special Inspection (8)
10/15/2020
Signed off — Alteration
PROPOSED TO REPLACE BRICK WALL AT EXPOSURE#4. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00382542-I1
10/01/2020
Special inspection requirement — Final
YUK LAM
10/01/2020
Special inspection requirement — Structural Stability – Alterations of existing buildings
YUK LAM
10/01/2020
Special inspection requirement — Masonry
YUK LAM
10/01/2020
Special inspection requirement — Post-installed Anchors
CHENG-SHENG HUANG
09/30/2020
Filed — Alteration
PROPOSED TO REPLACE BRICK WALL AT EXPOSURE#4. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00382542-P1
09/16/2020
Special inspection requirement — Masonry
YUK LAM
09/16/2020
Special inspection requirement — Structural Stability – Alterations of existing buildings
YUK LAM
09/16/2020
Special inspection requirement — Post-installed Anchors
CHENG-SHENG HUANG
09/16/2020
Special inspection requirement — Final
YUK LAM
08/21/2020
Permit issued — Structural
B00382542-I1-ST
08/12/2020
Filed — Alteration
PROPOSED TO REPLACE BRICK WALL AT EXPOSURE#4. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00382542-I1
07/17/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/29/1990
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offL2 CONSTRUCTION INC08/21/2020
BISPLISSUEDCATMAN PLUMBING INC02/19/2015
BISOTISSUEDLIN CONSTRUCTION INC02/13/2015
BISPLISSUEDNEKA GENERAL CONTRACTING CORP.03/22/1991
BISOTISSUEDG.R.J. HUB HOME IMPROV CENTER02/13/1991
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
10/01/2020FinalYUK LAMprogress
10/01/2020Structural Stability – Alterations of existing buildingsYUK LAMspecial
10/01/2020MasonryYUK LAMspecial
10/01/2020Post-installed AnchorsCHENG-SHENG HUANGspecial
09/16/2020MasonryYUK LAMspecial
09/16/2020Structural Stability – Alterations of existing buildingsYUK LAMspecial
09/16/2020Post-installed AnchorsCHENG-SHENG HUANGspecial
09/16/2020FinalYUK LAMprogress
▾Documents — 39 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Structural2
09/02/2026B00382542-I1Request digital key ↗
08/15/2026B00382542-P1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
05/05/2015340230761Open ↗
02/12/2015340230761Open ↗
▸BISWORK PERMIT APPLICATION1
02/12/2015340230761Open ↗
▸Seals & Professional Certifications14
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026B00382542-P1Open ↗
09/01/2026B00382542-P1Open ↗
09/01/2026B00382542-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00382542-P1Open ↗
08/13/2026B00382542-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00382542-P1Open ↗
08/24/2026B00382542-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/12/2015340230761Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/12/2015340230761Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/03/2015340230761Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
02/12/2015340230761Open ↗
▸Trade Schedules & Equipment5
▸BISSELF-CERT PLUMBING NOTICE2
08/17/2015340230761Open ↗
08/04/2015340230761Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
05/18/2015340230761Open ↗
05/05/2015340230761Open ↗
▸BISSCHEDULE B - PLUMBING1
02/12/2015340230761Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B00382542-I1Open ↗
08/13/2026B00382542-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/12/2015340230761Open ↗
▸Energy Compliance4
▸BISAS-BUILT ENERGY ANALYSIS1
08/03/2015340230761Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
02/12/2015340230761Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/03/2015340230761Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
02/12/2015340230761Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/12/2015340230761Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/03/2015340230761Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
08/03/2015340230761Open ↗
02/12/2015340230761Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
07/22/2015340230761Open ↗
05/18/2015340230761Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
02/12/2015340230761Open ↗
▸Other Documents1
▸BISOP-4 - Special Report1
08/03/2015340230761Open ↗