← Back
Primarily 1 family with 1 store or office
287 COURT STREET
💬 Discuss this project
1931Year Built
3Stories
S1Building Class
R6AZoning
2,100 sfGross Floor Area
2Units
0 Open Violations
Primarily 1 family with 1 store or office · Owner of record: SUNNY BAY, LLC · 1,552 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction32p · 2 filings · 20 docs
Floor 4Under Construction34p · 2 filings · 20 docs
Floor 3Under Construction25p · 2 filings · 20 docs
Floor 2Under Construction34p · 2 filings · 20 docs
Floor 1Under Construction35p · 2 filings · 20 docs
CellarUnder Construction38p · 3 filings · 20 docs
Site & exteriorUnder Construction24p · 2 filings · 14 docs
Filed — no permit issued24p · 2 filings · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MARPAT CONSTRUCTION103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/25/2022$2.0M—— → —$957/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHRIS KIM ENGINEERING PC105/14/2026
ALWAYS FAST SERVICES CORP404/27/2026
OLD STRUCTURES ENGINEERING311/18/2024
EP ENGINEERING LLC307/07/2023
CHOSHIELDS STUDIO101/20/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SATWIN ARCHITECT, PC1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MARPAT CONSTRUCTION CORPGeneral Contractor1209/16/2026
PHOENIX SUTTON STR INCGeneral Contractor204/09/2026
DV PLUMBING INCPlumbing207/08/2026
POWER SURGE ELECTRIC, INCElectrical103/22/2026
RICHARD NEUElectrical103/22/2026
BROOKLYN SOLARWORKS LLCGeneral Contractor106/07/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BARUN CORP8842105/14/2026
BILOW ENGINEERING LLC4095211/18/2024
SANDEEP GUNNALA ENGINEERI8482711/18/2024
STREET CONSULTING ENGINEE4259107/07/2023
Building Lifecycle
All (94)Filed (12)Permit Issued (15)Violation (1)Objection (36)Special Inspection (30)
09/15/2026
Permit issued — General Construction
B00802089-I1-GC
06/16/2026
Permit issued — Plumbing
B00859179-I1-PL
05/15/2026
Permit issued — Solar
B01397553-I1-SL
05/14/2026
Filed — Alteration
INSTALL SOLAR PV ON EXISTING ROOFTOP. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B01397553-I1
05/14/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
CHRIS KIM
05/14/2026
Special inspection requirement — Air barrier - visual inspection
CHRIS KIM
05/05/2026
Special inspection requirement — Final
CHRIS KIM
05/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRIS KIM
05/05/2026
Special inspection requirement — Energy Code Compliance Inspections
CHRIS KIM
04/27/2026
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE.LIVE LOAD 300PSF.
B01309443-P3
02/03/2026
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE.LIVE LOAD 300PSF.
B01309443-P2
01/26/2026
Permit issued — Foundation
B00802089-S3-FO
01/26/2026
Permit issued — General Construction
B00802089-I1-GC
01/23/2026
Permit issued — Structural
B00802089-S2-ST
12/19/2025
Permit issued — Structural
B00802089-S2-ST
12/19/2025
Permit issued — Foundation
B00802089-S3-FO
12/19/2025
Permit issued — General Construction
B00802089-I1-GC
12/12/2025
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE.LIVE LOAD 300PSF.
B01309443-P1
11/14/2025
Permit issued — Supported Scaffold
B01309443-I1-SH
11/14/2025
Permit issued — Sidewalk Shed
B01309443-I1-SF
11/13/2025
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AND PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE.LIVE LOAD 300PSF.
B01309443-I1
06/02/2025
Permit issued — Plumbing
B00859179-I1-PL
04/16/2025
Violation issued (ECB, closed)
Construction
01/24/2025
Permit issued — Foundation
B00802089-S3-FO
01/23/2025
Permit issued — Structural
B00802089-S2-ST
01/22/2025
Permit issued — General Construction
B00802089-I1-GC
11/18/2024
Filed — Alteration CO
Structural work for ALT-CO application on floor CEL, 001-005, bulkhead and roof.
B00802089-P1
11/06/2024
Special inspection requirement — Lowest Floor Elevation
11/06/2024
Special inspection requirement — Final
Sandeep Gunnala
11/06/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Sandeep Gunnala
11/06/2024
Special inspection requirement — Helical Piles Foundation (BB # 2014-020)
11/06/2024
Special inspection requirement — Concrete - Cast-In-Place
Sandeep Gunnala
11/06/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
11/06/2024
Special inspection requirement — Subgrade Inspections
JONATHAN BILOW
11/06/2024
Special inspection requirement — Footing and Foundation
Sandeep Gunnala
11/10/2023
Filed — Alteration CO
Structural work for ALT-CO application on floor CEL, 001-005, bulkhead and roof.
B00802089-S3
08/01/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Sandeep Gunnala
08/01/2023
Special inspection requirement — HVAC-R and service water heating system controls
Sandeep Gunnala
08/01/2023
Special inspection requirement — Maintenance information
Sandeep Gunnala
08/01/2023
Special inspection requirement — HVAC-R and service water heating equipment
Sandeep Gunnala
07/19/2023
Special inspection requirement — Duct leakage testing, insulation and design
Sandeep Gunnala
07/17/2023
Objection raised — Energy
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Admin
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Scope
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Structural
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Structural
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Structural
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Admin
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Zoning
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Scope
07/17/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Scope
Latest 60 of 94 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMARPAT CONSTRUCTION CORP09/15/2026
DOB NOWPlumbingPermit IssuedDV PLUMBING INC06/16/2026
DOB NOWSolarPermit IssuedBROOKLYN SOLARWORKS LLC05/15/2026
DOB NOWFoundationPermit IssuedMARPAT CONSTRUCTION CORP01/26/2026
DOB NOWGeneral ConstructionPermit IssuedMARPAT CONSTRUCTION CORP01/26/2026
DOB NOWStructuralPermit IssuedMARPAT CONSTRUCTION CORP01/23/2026
DOB NOWStructuralPermit IssuedMARPAT CONSTRUCTION CORP12/19/2025
DOB NOWFoundationPermit IssuedMARPAT CONSTRUCTION CORP12/19/2025
DOB NOWGeneral ConstructionPermit IssuedMARPAT CONSTRUCTION CORP12/19/2025
DOB NOWSupported ScaffoldPermit IssuedPHOENIX SUTTON STR INC11/14/2025
DOB NOWSidewalk ShedPermit IssuedPHOENIX SUTTON STR INC11/14/2025
DOB NOWPlumbingPermit IssuedDV PLUMBING INC06/02/2025
DOB NOWFoundationPermit IssuedMARPAT CONSTRUCTION CORP01/24/2025
DOB NOWStructuralPermit IssuedMARPAT CONSTRUCTION CORP01/23/2025
DOB NOWGeneral ConstructionPermit IssuedMARPAT CONSTRUCTION CORP01/22/2025
1 project · most recent 07/07/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/07/2023——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MITSUBISHI - MXZ-SM60NAM 60,000 BTU · Heat Pump Outdoor ×2
MITSUBISHI - MXZ-SM60NAM 60,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 07/07/2023
FiledStatusContractorScope
07/07/2023———
1 project · most recent 07/07/2023
Storm Water/Sanitary
FiledStatusContractorScope
07/07/2023Permit IssuedDV PLUMBING INCStorm, Water/Sanitary
3 projects · most recent 05/14/2026
General Wiring
FiledStatusContractorScope
05/14/2026Permit IssuedBROOKYLN SOLARWORKS, LLC—
11/15/2025Permit IssuedRICHARD NEU—
07/15/2025Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
1 project · most recent 11/18/2024
Steel
FiledStatusContractorScope
11/18/2024Permit IssuedMARPAT CONSTRUCTION CORPSteel
1 project · most recent 05/14/2026
FiledStatusContractorScope
05/14/2026Permit IssuedBROOKLYN SOLARWORKS LLC12 panels, 5.28 kw, 1,954 roof_area_sqft
1 project · most recent 04/27/2026
Scaffold Sidewalk Shed
FiledStatusContractorScope
04/27/2026Permit IssuedPHOENIX SUTTON STR INCScaffold, Sidewalk Shed
▾Special Inspection Requirements (DOB NOW) — 59
DateRequirementInspectorRole
05/14/2026Structural Stability – Alterations of existing buildingsCHRIS KIMspecial
05/14/2026Air barrier - visual inspectionCHRIS KIMenergy_progress
05/05/2026FinalCHRIS KIMprogress
05/05/2026Fire-Resistant Penetrations and JointsCHRIS KIMspecial
05/05/2026Energy Code Compliance InspectionsCHRIS KIMprogress
11/06/2024Lowest Floor Elevation—progress
11/06/2024FinalSandeep Gunnalaprogress
11/06/2024Structural Stability – Alterations of existing buildingsSandeep Gunnalaspecial
11/06/2024Helical Piles Foundation (BB # 2014-020)—special
11/06/2024Concrete - Cast-In-PlaceSandeep Gunnalaspecial
11/06/2024Subsurface Investigations (Borings/Test Pits)—special
11/06/2024Subgrade InspectionsJONATHAN BILOWspecial
11/06/2024Footing and FoundationSandeep Gunnalaprogress
08/01/2023HVAC-R and service water piping design and insulationSandeep Gunnalaenergy_progress
08/01/2023HVAC-R and service water heating system controlsSandeep Gunnalaenergy_progress
08/01/2023Maintenance informationSandeep Gunnalaenergy_progress
08/01/2023HVAC-R and service water heating equipmentSandeep Gunnalaenergy_progress
07/19/2023Duct leakage testing, insulation and designSandeep Gunnalaenergy_progress
06/21/2023Structural Stability – Alterations of existing buildingsSandeep Gunnalaspecial
06/08/2023HVAC-R and service water piping design and insulationSandeep Gunnalaenergy_progress
06/08/2023Fire-Resistant Penetrations and JointsSandeep Gunnalaspecial
06/08/2023Post-installed AnchorsSandeep Gunnalaspecial
06/08/2023Maintenance informationSandeep Gunnalaenergy_progress
06/08/2023HVAC-R and service water heating equipmentSandeep Gunnalaenergy_progress
06/08/2023Shutoff dampersSandeep Gunnalaenergy_progress
Latest 25 of 59.
▾Documents — 69 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/27/2026B00802089-I1Request digital key ↗
08/27/2026B00802089-P1Request digital key ↗
08/27/2026B00802089-S3Request digital key ↗
Showing 3 of 12 on file for this type
▸Applications & Permits1
▸BISBPP-5 - Authorization to the Department of Transportation1
01/25/2024340898005Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B00802089-I1Open ↗
▸Seals & Professional Certifications32
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/27/2026B00859179-I1Open ↗
08/27/2026B00859192-I1Open ↗
08/17/2026B01309443-P3Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/02/2026B00859192-I1Open ↗
09/02/2026B00859192-I1Open ↗
08/28/2026B00802089-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/02/2026B00859192-I1Open ↗
08/28/2026B00802089-I1Open ↗
08/28/2026B00802089-I1Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
08/29/2023340898005Open ↗
▸Safety & Tenant Protection4
▸BISBPP: STREET TREES SITE PLAN1
08/29/2023340898005Open ↗
▸BISSTREET TREE CHECKLIST1
01/25/2024340898005Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026B00802089-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00802089-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form5
08/17/2026B01397553-I1Open ↗
08/14/2026B00859179-I1Open ↗
08/13/2026B00802089-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B00802089-S3Open ↗
08/13/2026B00802089-P1Open ↗
▸Inspections & Test Reports3
▸DOB NOWSOIL REPORT2
08/13/2026B00802089-S3Open ↗
08/13/2026B00802089-P1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00802089-S3Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
01/05/2024340898005Open ↗
10/27/2023340898005Open ↗
10/27/2023340898005Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
08/29/2023340898005Open ↗
▸Other Documents5
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
08/29/2023340898005Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B00802089-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00802089-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026B00802089-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026B00802089-I1Open ↗