← Back
Five to six families
294 STANHOPE STREET
BROOKLYN · BIN 3074529
💬 Discuss this project
1931Year Built
3Stories
C2Building Class
R6Zoning
3,750 sfGross Floor Area
6Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Five to six families · Owner of record: JOSEPH COLLURA REALTY LLC · 2,500 sf lot · 1.5 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 11p · 1 filing · 20 docs
Cellar1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NAPOLITANO PROPERTIES1107/08/2026
JOSEPH COLLURA REALTY LLC203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOSEPH GIANNETTI ARCHITECT507/20/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CRF CONSTRUCTION INCGeneral Contractor1203/21/2026
SOUTH HEIGHTS ELECTRIC COElectrical203/22/2026
TOP DOG PLBG & HTG CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CITY-WIDE TESTING INC416307/20/2026
Building Lifecycle
All (30)Filed (5)Permit Issued (6)Violation (19)
07/20/2026
Filed — Alteration
INSTALL DUCTLESS AIR CONDITIONING AND HEATING SPLIT SYSTEM HEAT PUMPS AND EXHAUST FANS
B00952915-P2
07/22/2025
Permit issued — Mechanical Systems
B00952915-S2-MS
07/22/2025
Permit issued — Foundation
B00952915-I1-GC-CX
02/13/2025
Filed — Alteration
INSTALL DUCTLESS AIR CONDITIONING AND HEATING SPLIT SYSTEM HEAT PUMPS AND EXHAUST FANS
B00952915-P1
01/16/2025
Permit issued — Plumbing
B00952915-S1-PL
12/24/2024
Permit issued — Mechanical Systems
B00952915-S2-MS
10/25/2024
Filed — Alteration
INSTALL DUCTLESS AIR CONDITIONING AND HEATING SPLIT SYSTEM HEAT PUMPS AND EXHAUST FANS
B00952915-S2
04/11/2024
Violation issued (HPD, closed)
A
02/26/2024
Permit issued — Plumbing
B00952915-S1-PL
01/19/2024
Filed — Alteration
INSTALL DUCTLESS AIR CONDITIONING AND HEATING SPLIT SYSTEM HEAT PUMPS AND EXHAUST FANS
B00952915-S1
12/29/2023
Permit issued — Foundation
B00952915-I1-GC-CX
11/22/2023
Violation issued (HPD, closed)
I
10/30/2023
Filed — Alteration
INSTALL DUCTLESS AIR CONDITIONING AND HEATING SPLIT SYSTEM HEAT PUMPS AND EXHAUST FANS
B00952915-I1
03/27/2023
Violation issued (HPD, closed)
A
11/14/2022
Violation issued (HPD, closed)
I
03/02/2022
Violation issued (HPD, closed)
A
10/20/2021
Violation issued (HPD, closed)
B
10/20/2021
Violation issued (HPD, closed)
C
10/20/2021
Violation issued (HPD, closed)
B
10/20/2021
Violation issued (HPD, closed)
C
10/20/2021
Violation issued (HPD, closed)
B
10/20/2021
Violation issued (HPD, closed)
B
10/20/2021
Violation issued (HPD, closed)
C
10/18/2021
Violation issued (HPD, closed)
C
04/13/2021
Violation issued (HPD, closed)
A
08/04/2014
Violation issued (ECB, closed)
Construction
12/29/2013
Violation issued (HPD, closed)
B
03/01/2013
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/13/2011
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/25/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCRF CONSTRUCTION INC07/22/2025
DOB NOWFoundationSigned-offCRF CONSTRUCTION INC07/22/2025
DOB NOWPlumbingSigned-offTOP DOG PLBG & HTG CORP01/16/2025
DOB NOWMechanical SystemsSigned-offCRF CONSTRUCTION INC12/24/2024
DOB NOWPlumbingSigned-offTOP DOG PLBG & HTG CORP02/26/2024
DOB NOWFoundationSigned-offCRF CONSTRUCTION INC12/29/2023
1 project · most recent 07/20/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/20/2026Signed-offCRF CONSTRUCTION INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Gree GREE SPLIT TYPE AIR CONDITIONER 4LIV07HP230V1AH 7,000 BTU · Heat Pump Outdoor ×2
GREE SPLIT TYPE AIR CONDITIONER 4LIV12HP230V1AH 12,000 BTU ×1
GREE SPLIT TYPE AIR CONDITIONER 4LIV18HP230V1AH 17,600 BTU · Heat Pump Outdoor ×1
GREE SPLIT TYPE AIR CONDITIONER MULTI42HP230V1EO 36,000 BTU · Heat Pump Outdoor ×1
Ventilation
Panasonic FV-0510VS1 80 CFM · Exhaust Fan ×2
General Electric JVX5305EJES 270 CFM · Kitchen Exhaust ×1
1 project · most recent 07/20/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/20/2026Signed-offTOP DOG PLBG & HTG CORPGas, Water/Sanitary
2 projects · most recent 08/13/2025
General Wiring
FiledStatusContractorScope
08/13/2025Permit IssuedSOUTH HEIGHTS ELECTRIC COGeneral Wiring
07/07/2025CompleteSOUTH HEIGHTS ELECTRIC CO7 meters, 1 new_meters
1 project · most recent 07/20/2026
Steel Wood
FiledStatusContractorScope
07/20/2026Signed-offCRF CONSTRUCTION INCSteel, Wood
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
08/03/2026Fail-Final General Construction Non-Directive 14FailView ↗
09/22/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
03/01/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/01/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/01/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/07/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/07/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/02/2023Pass-Final PL - UndergroundPassView ↗
02/21/2023Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
07/20/2026Lighting in dwelling unitsJOSEPH GIANNETTIenergy_progress
07/20/2026Wood – Seismic Resistance—special
07/20/2026Fenestration areasJOSEPH GIANNETTIenergy_progress
07/20/2026Fire-Resistant Penetrations and JointsELIAS RASABIspecial
07/20/2026Structural Steel - DetailsELIAS RASABIspecial
07/20/2026Subgrade InspectionsELIAS RASABIspecial
07/20/2026Structural Stability – Alterations of existing buildingsELIAS RASABIspecial
07/20/2026Structural Steel - WeldingELIAS RASABIspecial
07/20/2026Tenant Protection Plan ComplianceELIAS RASABIspecial
07/20/2026Wood – Seismic Resistance—special
07/20/2026Concrete - Cast-In-PlaceELIAS RASABIspecial
07/20/2026Fire-Resistance Rated ConstructionELIAS RASABIprogress
07/20/2026Energy Code Compliance InspectionsJOSEPH GIANNETTIprogress
07/20/2026Structural Wood FrameELIAS RASABIprogress
07/20/2026Footing and FoundationELIAS RASABIprogress
07/20/2026FinalELIAS RASABIprogress
07/20/2026Insulation placement and R valuesJOSEPH GIANNETTIenergy_progress
07/20/2026Fenestration and door U-factor and product ratingsJOSEPH GIANNETTIenergy_progress
07/20/2026Fenestration air leakageJOSEPH GIANNETTIenergy_progress
07/20/2026Air barrier - visual inspectionJOSEPH GIANNETTIenergy_progress
07/19/2026Fenestration areasJOSEPH GIANNETTIenergy_progress
07/19/2026Structural Wood FrameELIAS RASABIprogress
07/19/2026Insulation placement and R valuesJOSEPH GIANNETTIenergy_progress
07/19/2026Fenestration air leakageJOSEPH GIANNETTIenergy_progress
07/19/2026Fenestration and door U-factor and product ratingsJOSEPH GIANNETTIenergy_progress
Latest 25 of 44.
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/23/2026B00952915-I1Request digital key ↗
08/23/2026B00952915-P2Request digital key ↗
08/23/2026B00952915-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications27
▸DOB NOWProgress Inspector Seal & Signature20
09/26/2026B00952915-P2Open ↗
09/26/2026B00952915-P2Open ↗
09/26/2026B00952915-P2Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/23/2026B00952915-P2Open ↗
08/13/2026B00952915-I1Open ↗
08/13/2026B00952915-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/26/2026B00952915-P2Open ↗
09/02/2026B00952915-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/23/2026B00952915-P2Open ↗
08/13/2026B00952915-I1Open ↗
08/13/2026B00952915-S1Open ↗
Showing 3 of 5 on file for this type