← Back
Condo, residential tower (mixed-use, multi-family elevator) [derived]
Whitney
311 EAST 38 STREET · Murray Hill-Kips Bay · BIN 1021933
💬 Discuss this project
1984Year Built
28Stories
RMBuilding Class
C1-9Zoning
88,135 sfGross Floor Area
119Units
LL97 CoveredRent Stabilized26 Open Violations 22 unresolved · 4 paperwork only ▸FISP: No Report Filed
Condo, residential tower (mixed-use, multi-family elevator) [derived] · 9,391 sf lot · 9.39 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentLandscapeGeneral
Penthouse9p · 1 filing · 6 docs
Floor 281 filing · 16 docs
Floor 27
Floor 26
Floor 254p · 2 filings · 9 docs
Floor 24
Floor 231p · 1 filing · 11 docs
Floor 22
Floor 21
Floor 20
Floor 19
Floor 18
Floor 17
Floor 16
Floor 15
Floor 142p · 1 filing · 16 docs
Floor 13
Floor 12
Floor 11
Floor 10
Floor 9
Floor 8
Floor 7
Floor 6
Floor 5
Floor 4
Floor 3
Floor 2
Floor 1
Site & exterior9p · 2 filings · 4 docs
Filed — no permit issued10p · 2 filings · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WHITNEY CONDOMINIUM4603/21/2026
WHITNEY CONDOMINIUM C O DOUGLA503/21/2026
PHOENIX BRIDGING INC DBA PHOENI203/21/2026
Charter Communications103/22/2026
ROCK GROUP NY CORP103/21/2026
WHITNEY103/21/2026
QUANTUM DESIGN103/21/2026
DOUGLAS ELLIMAN-WHITENY CONDO103/21/2026
HPD103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CQ&J CORPORATION208/31/2025
WEI STUDIO208/08/2024
HC ARCHITECT, PC404/05/2024
MG NEW YORK ARCHITECTS,PLLC207/24/2023
LOREN E CANNON ARCHITECT111/30/2021
FL&M ENGINEERING DESIGN &INSPECTION111/15/2021
ASIF JAMIL, RA111/01/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MJ EXPEDITNG SERVICE803/21/2026
CONVERSANO ASSOCIATES, INC.403/21/2026
FRANKLYN ESTRELLA ARCHITECT PLLC203/21/2026
GREEN STUDIO403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JSD CONSTRUCTION GROUP INGeneral Contractor407/08/2026
GG CONSTRUCTION CONTRACTGeneral Contractor303/21/2026
ROCK GROUP NY CORPGeneral Contractor303/21/2026
JOSEPH FERGUSONElectrical103/21/2026
JOSEPH WEINSTEIN ELECTRICElectrical103/22/2026
RICHARDS, REUBENElectrical103/21/2026
RIVIERA ELECTRIC CORPElectrical103/22/2026
ROBERT CHIMENTIElectrical103/22/2026
UNITED ELEC'L CONT'G CORPElectrical103/22/2026
WENKE, THOMASElectrical103/21/2026
JTONIC DESIGN & CONSTRUCTGeneral Contractor107/08/2026
LCS RESTORATION CORPGeneral Contractor107/08/2026
PSI CONSTRUCTION.LLCGeneral Contractor107/08/2026
ARANDA PLBG & HTG CORPPlumbing107/08/2026
BKNY PLUMBING & HEATING IPlumbing107/08/2026
GIL GLICKPlumbing107/08/2026
ENDRES, ROLFElectrical103/21/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
HENRY KHODOSHElectrical103/21/2026
HIGH RISE CONSTRUCTION INElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WEI STUDIO7998208/08/2024
BEYOND ARCH LLC3600304/05/2024
MG NEW YORK ARCHITECTS, P3444207/24/2023
Building Lifecycle
All (151)Filed (14)Permit Issued (11)Signed Off (5)Facade (FISP) (11)Violation (60)Inspection (7)Objection (18)Special Inspection (25)
05/20/2026
Filed — Alteration
IRA to assist with Condition Assessment
M01405013-I1
10/10/2025
Objection resolved — Addressed
10/10/2025
Objection resolved — Addressed
09/10/2025
Objection raised — Admin
09/10/2025
Objection raised — Admin
08/31/2025
Filed — Alteration
Plumbing work in conjucntion with Alt # M01176978-I1
M01176978-I1
08/31/2025
Filed — Alteration
Plumbing work in conjucntion with Alt # M01176978-I1
M01176978-S1
07/07/2025
Violation issued (ECB, open)
Zoning
02/05/2025
Special inspection requirement — Final
02/05/2025
Special inspection requirement — Mechanical Systems
10/16/2024
Signed off — Alteration
HEREWITH FILE PLANS FOR MINOR INTERIOR RENOVATION OF AN EXISTING APT UNIT 23A. INTERIOR PARTITION TO BE REMOVED TO CREATE AN OPEN KITCHEN. NO CHANGE IS USE, EGRESS AND OCCUPANCY.
M01018258-S1
09/26/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/26/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/09/2024
Signed off — Alteration
Filing herewith for modifications to existing plumbing system
M00888202-I1
09/04/2024
Signed off — Alteration
Filing herewith for modifications to existing plumbing system
M00888202-S1
08/21/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
08/20/2024
Signed off — Alteration
UNIT 14E MINOR INTERIOR RENOVATION. REMOVE INTERIOR NON LOAD BEARING PARTITIONS, INSTALL NEW NON LOAD BEARING PARTITIONS AND KITCHEN CABINETS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01053409-I1
08/20/2024
Special inspection requirement — Final
Ruoyu Wei
08/20/2024
Special inspection requirement — Tenant Protection Plan Compliance
Ruoyu Wei
08/20/2024
Special inspection requirement — Lighting in dwelling units
Ruoyu Wei
08/20/2024
Special inspection requirement — Lighting controls
Ruoyu Wei
08/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ruoyu Wei
08/14/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/14/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/12/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/08/2024
Filed — Alteration
UNIT 14E MINOR INTERIOR RENOVATION. REMOVE INTERIOR NON LOAD BEARING PARTITIONS, INSTALL NEW NON LOAD BEARING PARTITIONS AND KITCHEN CABINETS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01053409-P1
08/01/2024
Permit issued — Plumbing
M00888202-S1-PL
07/31/2024
Special inspection requirement — Lighting controls
Ruoyu Wei
07/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ruoyu Wei
07/31/2024
Special inspection requirement — Tenant Protection Plan Compliance
Ruoyu Wei
07/31/2024
Special inspection requirement — Final
Ruoyu Wei
07/31/2024
Special inspection requirement — Lighting in dwelling units
Ruoyu Wei
06/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/30/2024
Permit issued — General Construction
M01053409-I1-GC
05/21/2024
Filed — Alteration
UNIT 14E MINOR INTERIOR RENOVATION. REMOVE INTERIOR NON LOAD BEARING PARTITIONS, INSTALL NEW NON LOAD BEARING PARTITIONS AND KITCHEN CABINETS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01053409-I1
05/20/2024
Permit issued — Plumbing
M01018258-S1-PL
04/16/2024
Objection raised — Scope
04/16/2024
Objection resolved — Addressed
04/05/2024
Filed — Alteration
HEREWITH FILE PLANS FOR MINOR INTERIOR RENOVATION OF AN EXISTING APT UNIT 23A. INTERIOR PARTITION TO BE REMOVED TO CREATE AN OPEN KITCHEN. NO CHANGE IS USE, EGRESS AND OCCUPANCY.
M01018258-S1
04/05/2024
Filed — Alteration
HEREWITH FILE PLANS FOR MINOR INTERIOR RENOVATION OF AN EXISTING APT UNIT 23A. INTERIOR PARTITION TO BE REMOVED TO CREATE AN OPEN KITCHEN. NO CHANGE IS USE, EGRESS AND OCCUPANCY.
M01018258-I1
03/11/2024
Special inspection requirement — Lighting in dwelling units
Hackjong Choi
03/11/2024
Special inspection requirement — Tenant Protection Plan Compliance
Hackjong Choi
03/11/2024
Special inspection requirement — Energy Code Compliance Inspections
Hackjong Choi
03/11/2024
Special inspection requirement — Tenant Protection Plan Compliance
Hackjong Choi
03/11/2024
Special inspection requirement — Final
Withdrawn
12/15/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/02/2023
Permit issued — Plumbing
M00888202-S1-PL
09/08/2023
Permit issued — General Construction
M00888202-I1-GC
07/24/2023
Filed — Alteration
Filing herewith for modifications to existing plumbing system
M00888202-S1
07/21/2023
Filed — Alteration
Filing herewith for modifications to existing plumbing system
M00888202-I1
04/22/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/16/2023
Cycle 9 facade inspection completed
12/21/2022
Violation issued (ECB, open)
Local Law
08/21/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/20/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/07/2022
Permit issued — Plumbing
M00758067-I1-PL
07/04/2022
Permit issued — General Construction
M00758049-I1-GC
06/16/2022
Filed — Alteration
HEREWITH FILE PLANS FOR INTERIOR RENOVATION OF AN EXISTING APT UNIT 25A LOCATED ON 25TH FLOOR. GENERAL CONSTRUCTION INCLUDES NON-LOAD BEARING PARTITIONS, NEW FLOOR, CEILING WITH NEW FINISHES THROUGHOUT ENTIRE UNIT. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
M00758049-I1
06/16/2022
Filed — Alteration
M00758067-I1
06/15/2022
Special inspection requirement — Lighting in dwelling units
Hackjong Choi
Latest 60 of 151 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBKNY PLUMBING & HEATING I08/01/2024
DOB NOWGeneral ConstructionSigned-offJTONIC DESIGN & CONSTRUCT05/30/2024
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR05/20/2024
DOB NOWPlumbingSigned-offGIL GLICK10/02/2023
DOB NOWGeneral ConstructionSigned-offPSI CONSTRUCTION.LLC09/08/2023
DOB NOWPlumbingPermit IssuedARANDA PLBG & HTG CORP07/07/2022
DOB NOWGeneral ConstructionPermit IssuedGG CONSTRUCTION CONTRACT07/04/2022
DOB NOWGeneral ConstructionSigned-offJSD CONSTRUCTION GROUP IN02/04/2022
DOB NOWGeneral ConstructionSigned-offJSD CONSTRUCTION GROUP IN12/30/2021
DOB NOWSidewalk ShedPermit IssuedLCS RESTORATION CORP11/15/2021
DOB NOWConstruction FencePermit IssuedROCK GROUP NY CORP11/02/2018
BISOTISSUEDSOHO CONTRACTING CORP06/26/2019
BISEQISSUEDROCK GROUP NY CORP02/14/2019
BISOTISSUEDSOHO CONTRACTING CORP06/26/2018
BISEQISSUEDROCK GROUP NY CORP02/07/2018
BISOTISSUEDSOHO CONTRACTING CORP01/25/2018
BISPLISSUEDCOCHRANE PLBG & HTG01/18/2018
BISPLISSUEDAUTHENTIC PLBG CORP01/16/2018
BISOTISSUEDGSK CONTRACTING CORP01/11/2018
BISOTISSUEDL & N CONSTRUCTION INTERI05/18/2017
BISPLISSUEDTOP PLUMBING GROUP,INC04/20/2017
BISOTISSUEDJA & JGENERAL CONSTRUCTIO04/12/2017
BISEQISSUEDROCK GROUP NY CORP02/13/2017
BISEQISSUEDPHOENIX SUTTON STR INC08/15/2013
BISOTISSUEDINTER CONSTRUCTION CORP04/15/2013
BISOTISSUEDINTER CONSTRUCTION CORP03/20/2013
BISEQISSUEDPHOENIX SUTTON STR INC03/19/2013
BISOTISSUEDPL-EURO CONSTRUCTION CORP03/15/2013
BISPLISSUEDA & C HTG SERVICES, INC01/28/2013
BISPLISSUEDPREMIER FLOW PLBG AND HTG12/24/2012
BISOTISSUEDPL-EURO CONSTRUCTION CORP12/20/2012
BISEQISSUEDPHOENIX BRIDGING INC06/22/2012
BISPLISSUEDMPC PLUMBING & HEATING INC06/01/2012
BISOTISSUEDCHAMPION CONTRUCTION CORP05/25/2012
BISBLISSUEDA&C HEATING SERVICES INC08/18/2011
BISPLISSUEDA & C HTG SERVICES, INC08/18/2011
BISOTISSUEDJ AND J ASSOCIATE NYINC07/25/2011
BISOTISSUEDJESUS CONSTRUCTION & GLAS02/15/2011
BISOTISSUEDOMNI CONSTRUCTION CORP10/05/2009
BISEQISSUEDPOWERS BRIDGING & SCAFFOLDING10/01/2009
+ 18 more permits on file
1 project · most recent 08/31/2025
Air Conditioning Systems
FiledStatusContractorScope
08/31/2025——Air Conditioning Systems
2 projects · most recent 08/31/2025
Water/Sanitary Gas
FiledStatusContractorScope
08/31/2025——Water/Sanitary
04/05/2024Signed-offINFINITI ESC PLUMBING CORGas, Water/Sanitary
11 projects · most recent 10/02/2026
General Wiring
FiledStatusContractorScope
10/02/2026Permit IssuedLENS ELECTRIC, INCGeneral Wiring
09/09/2025CompleteUNITED ELEC'L CONT'G CORPGeneral Wiring
10/28/2024CompleteRIVIERA ELECTRIC CORPGeneral Wiring
05/29/2024CompleteGOODALL ELECTRIC CORP—
05/13/2024CompleteSUPREME ELECTRIC CORPGeneral Wiring
07/12/2022CompleteBIG CITY ELECL SOLUTIONSGeneral Wiring
05/03/2022CompleteROBERT CHIMENTI2 meters, 1 new_meters
01/18/2022CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
11/16/2021Permit IssuedRICHARD NEU—
09/14/2021Permit IssuedCITY LIGHTS ELECTRIC INC.General Wiring
12/11/2017CompleteALTEC E & M, INC. ELEC'L—
1 project · most recent 11/15/2021
Sidewalk Shed
FiledStatusContractorScope
11/15/2021Permit IssuedLCS RESTORATION CORPSidewalk Shed
1 project · most recent 05/20/2026
FiledStatusContractorScope
05/20/2026———
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
09/26/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/21/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/14/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/14/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/12/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/15/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
02/05/2025Final—progress
02/05/2025Mechanical Systems—special
08/20/2024FinalRuoyu Weiprogress
08/20/2024Tenant Protection Plan ComplianceRuoyu Weispecial
08/20/2024Lighting in dwelling unitsRuoyu Weienergy_progress
08/20/2024Lighting controlsRuoyu Weienergy_progress
08/20/2024Fire-Resistant Penetrations and JointsRuoyu Weispecial
07/31/2024Lighting controlsRuoyu Weienergy_progress
07/31/2024Fire-Resistant Penetrations and JointsRuoyu Weispecial
07/31/2024Tenant Protection Plan ComplianceRuoyu Weispecial
07/31/2024FinalRuoyu Weiprogress
07/31/2024Lighting in dwelling unitsRuoyu Weienergy_progress
03/11/2024Lighting in dwelling unitsHackjong Choienergy_progress
03/11/2024Tenant Protection Plan ComplianceHackjong Choispecial
03/11/2024Energy Code Compliance InspectionsHackjong Choiprogress
03/11/2024Tenant Protection Plan ComplianceHackjong Choispecial
03/11/2024FinalWithdrawnprogress
06/15/2022Lighting in dwelling unitsHackjong Choienergy_progress
06/15/2022Fire-Resistant Penetrations and JointsHackjong Choispecial
06/15/2022Energy Code Compliance InspectionsHackjong Choiprogress
06/15/2022FinalHackjong Choiprogress
11/30/2021Fire-Resistance Rated ConstructionLOREN CANNONprogress
11/30/2021Lighting in dwelling unitsLOREN CANNONenergy_progress
11/23/2021Energy Code Compliance InspectionsLOREN CANNONprogress
11/23/2021FinalLOREN CANNONprogress
▾Documents — 355 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch14
09/06/2026M00087320-I1Request digital key ↗
09/03/2026M00626406-I1Request digital key ↗
09/02/2026M00758067-I1Request digital key ↗
Showing 3 of 14 on file for this type
▸Applications & Permits67
▸BISPLAN / WORK APPROVAL APPLICATION35
04/18/2019123487351Open ↗
04/11/2019123487351Open ↗
03/29/2019123487351Open ↗
Showing 3 of 35 on file for this type
▸BISWORK PERMIT APPLICATION32
06/26/2019123274777Open ↗
02/15/2019140601800Open ↗
07/12/2018123274777Open ↗
Showing 3 of 32 on file for this type
▸Seals & Professional Certifications99
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION33
08/02/2019123487351Open ↗
08/02/2019123487351Open ↗
03/29/2019123525943Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWProgress Inspector Seal & Signature23
08/30/2026M01053409-P1Open ↗
08/30/2026M01053409-P1Open ↗
08/30/2026M01053409-P1Open ↗
Showing 3 of 23 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature13
09/06/2026M00087320-I1Open ↗
09/02/2026M00758067-I1Open ↗
09/02/2026M00758049-I1Open ↗
Showing 3 of 13 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST10
03/29/2019123525943Open ↗
04/10/2018123440188Open ↗
11/17/2017123109661Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
08/30/2026M01053409-P1Open ↗
08/30/2026M01053409-P1Open ↗
08/28/2026M01018258-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
09/04/2012121353490Open ↗
06/25/2012121122132Open ↗
Showing 2 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
03/29/2019123525943Open ↗
04/10/2018123440188Open ↗
11/17/2017123109661Open ↗
Showing 3 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
03/31/2017140623822Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/11/2017140601800Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
02/11/2017140601800Open ↗
▸Trade Schedules & Equipment20
▸BISSELF-CERT PLUMBING NOTICE6
07/23/2013121167904Open ↗
04/01/2013120795265Open ↗
03/26/2013121167904Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING6
06/01/2017140623822Open ↗
04/05/2017140623822Open ↗
10/15/2012121167904Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
03/29/2019123525943Open ↗
11/29/2018123487351Open ↗
11/29/2018123487351Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISBOILERS - SUPPORTING DOCUMENTATION1
01/09/2013120795265Open ↗
▸Safety & Tenant Protection10
▸BISTenant Protection Plan and Notes7
06/20/2019123487351Open ↗
03/29/2019123525943Open ↗
11/29/2018123487351Open ↗
Showing 3 of 7 on file for this type
▸BISSTREET TREE CHECKLIST3
11/29/2018123487351Open ↗
Showing 1 of 3 on file for this type
▸Environmental & Asbestos23
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/02/2026M00758067-I1Open ↗
09/02/2026M00758049-I1Open ↗
08/29/2026M00888202-I1Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
03/29/2019123525943Open ↗
11/29/2018123487351Open ↗
11/06/2017123274777Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)2
09/04/2012121353490Open ↗
09/04/2012121353490Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Energy Compliance22
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS14
08/02/2019123487351Open ↗
08/02/2019123487351Open ↗
11/29/2018123487351Open ↗
Showing 3 of 14 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS5
01/26/2018123226794Open ↗
06/21/2017140623822Open ↗
01/13/2014121353490Open ↗
Showing 3 of 5 on file for this type
▸BISTR8: Energy Code Progress Inspections1
09/04/2012121353490Open ↗
▸BISTECHNICAL REPORT: ENERGY1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026M00636550-I1Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
04/05/2017140623822Open ↗
02/11/2017140601800Open ↗
▸Approvals, Objections & Sign-offs28
▸BISADMINISTRATIVE OBJECTIONS10
08/29/2012121353490Open ↗
07/27/2012121167904Open ↗
06/22/2012121122132Open ↗
Showing 3 of 10 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST10
01/26/2018123226794Open ↗
06/21/2017140623822Open ↗
07/02/2014120095495Open ↗
Showing 3 of 10 on file for this type
▸BISSHED LETTER2
02/15/2019140601800Open ↗
09/05/2013121122132Open ↗
▸BISCONSTRUCTION CODE DETERMINATION2
11/16/2015121353490Open ↗
01/29/2013121353490Open ↗
▸BISLETTERS - APPROVED FABRICATION CERTIFICATIONS1
03/25/2013121122132Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
08/01/2019123487351Open ↗
▸BISSUPERSEDING LETTER1
07/12/2018123274777Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/14/2014121122132Open ↗
▸Cost, Insurance & Ownership26
▸BISCOST AFFIDAVIT26
08/02/2019123487351Open ↗
07/31/2019123487351Open ↗
03/29/2019123525943Open ↗
Showing 3 of 26 on file for this type
▸Filing & Intake Forms39
▸BISEFILING COVER SHEET20
03/29/2019123525943Open ↗
03/28/2019123487351Open ↗
11/29/2018123487351Open ↗
Showing 3 of 20 on file for this type
▸BISADDITIONAL INFORMATION13
10/31/2018140601800Open ↗
07/18/2018123274777Open ↗
05/23/2018140601800Open ↗
Showing 3 of 13 on file for this type
▸BISBOROUGH INTAKE FORM4
04/11/2019123487351Open ↗
05/22/2018140601800Open ↗
01/26/2018123226794Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
03/31/2017140623822Open ↗
02/11/2017140601800Open ↗
▸Other Documents5
▸BISPLOT DIAGRAM2
07/31/2019123487351Open ↗
11/29/2018123487351Open ↗
▸BISSEPTIC - SUPPORTING DOCUMENTATION1
02/11/2017140601800Open ↗
▸BISDepartment of Consumer Affairs (DCA) Form1
12/21/2012121167904Open ↗
▸DOB NOWIRA Certification1
08/17/2026M01405013-I1Open ↗