| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 04/04/2022 | $1.9M | — | ROCCO FERRIGNO TRUST → Private party | $926/sf building |
| 02/10/2014 | $1.5M | — | — → — | $700/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| TWIGCON LLC | 1 | 03/01/2026 |
| EAB ENGINEERING PC | 6 | 12/27/2024 |
| CHRISTOPHER TEETER | 2 | 11/16/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| METAMECHANICS ARCHITECTURE | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| M. INT'L ENGINEERING PLLC | General Contractor | 12 | 03/21/2026 |
| MR. AIR NYC CORP | General Contractor | 3 | 03/21/2026 |
| CROSSFIELD PLBG.&HTG | Plumbing | 2 | 07/08/2026 |
| JJAW SERVICE INC | General Contractor | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| EAB ENGINEERING, PC | 2048 | 8 | 12/27/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Permit Issued | JJAW SERVICE INC | 05/27/2026 |
| DOB NOW | Plumbing | Permit Issued | CROSSFIELD PLBG.&HTG | 05/01/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | MR. AIR NYC CORP | 02/11/2025 |
| DOB NOW | Structural | Permit Issued | M. INT'L ENGINEERING PLLC | 10/22/2024 |
| DOB NOW | Structural | Permit Issued | M. INT'L ENGINEERING PLLC | 10/18/2024 |
| DOB NOW | Structural | Permit Issued | M. INT'L ENGINEERING PLLC | 05/20/2024 |
| DOB NOW | General Construction | Permit Issued | M. INT'L ENGINEERING PLLC | 01/19/2024 |
| DOB NOW | Plumbing | Permit Issued | CROSSFIELD PLBG.&HTG | 12/11/2023 |
| BIS | MH | ISSUED | JOSHUA CONSTRUCTION CORP | 05/23/2019 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 12/27/2024 | Permit Issued | MR. AIR NYC CORP | Air Conditioning Systems, Heating Systems | Cooling Mitsubishi Electric MODEL: MUZ-FS09NA-U1, MUZ-FS15NA-U1, MXZ-3C24NAHZ4-U1, MXZ-3C30NAHZ4-U1 78,000 BTU · Condensing Unit ×4 Heating Mitsubishi Electric MODEL: MUZ-FS09NA-U1, MUZ-FS15NA-U1, MXZ-3C24NAHZ4-U1, MXZ-3C30NAHZ4-U1 84,000 BTU · Heat Pump Outdoor ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/01/2026 | — | — | 32 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/01/2026 | — | — | — |
| 11/16/2024 | Permit Issued | CROSSFIELD PLBG.&HTG | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/19/2024 | Permit Issued | J Y ELECTRIC INC | General Wiring |
| 04/03/2024 | Permit Issued | J Y ELECTRIC INC | General Wiring |
| 12/20/2022 | Permit Issued | J Y ELECTRIC INC | — |
| 06/17/2019 | Complete | JOSEPH WEINSTEIN ELECTRIC | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 04/09/2026 | Pass-Final PL Permit Withdrawal | Pass | View ↗ |
| 04/03/2026 | Fail-Final PL Permit Withdrawal | Fail | View ↗ |
| 07/29/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 11/27/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 01/25/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 01/25/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 01/23/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/14/2026 | Tenant Protection Plan Compliance | — | special |
| 09/26/2025 | Sprinkler Systems | — | special |
| 12/24/2024 | HVAC-R and service water piping design and insulation | Iraj Issapour | energy_progress |
| 12/24/2024 | Fire-Resistant Penetrations and Joints | Iraj Issapour | special |
| 12/24/2024 | Maintenance information | Iraj Issapour | energy_progress |
| 12/24/2024 | HVAC-R and service water heating system controls | Iraj Issapour | energy_progress |
| 12/24/2024 | HVAC-R and service water heating equipment | Iraj Issapour | energy_progress |
| 12/24/2024 | Energy Code Compliance Inspections | Iraj Issapour | progress |
| 12/23/2024 | Final | Iraj Issapour | progress |
| 12/23/2024 | Mechanical Systems | Iraj Issapour | special |
| 11/22/2024 | HVAC-R and service water piping design and insulation | Iraj Issapour | energy_progress |
| 11/22/2024 | Fire-Resistant Penetrations and Joints | Iraj Issapour | special |
| 11/22/2024 | Energy Code Compliance Inspections | Iraj Issapour | progress |
| 11/22/2024 | HVAC-R and service water heating equipment | Iraj Issapour | energy_progress |
| 11/22/2024 | Maintenance information | Iraj Issapour | energy_progress |
| 11/22/2024 | HVAC-R and service water heating system controls | Iraj Issapour | energy_progress |
| 11/16/2024 | Air barrier - visual inspection | Christopher Teeter | energy_progress |
| 11/16/2024 | Fenestration air leakage | Christopher Teeter | energy_progress |
| 11/16/2024 | Fenestration and door U-factor and product ratings | Christopher Teeter | energy_progress |
| 11/16/2024 | Fenestration areas | Christopher Teeter | energy_progress |
| 10/09/2024 | Final | ROMAN MARDAREWICH | progress |
| 10/09/2024 | Fire-Resistance Rated Construction | Christopher Teeter | progress |
| 10/09/2024 | Metering | Christopher Teeter | energy_progress |
| 10/09/2024 | Fire-Resistant Penetrations and Joints | Iraj Issapour | special |
| 10/09/2024 | Structural Stability – Alterations of existing buildings | Iraj Issapour | special |