← Back
Two family brick
32 WOODHULL STREET
💬 Discuss this project
1910Year Built
3Stories
B1Building Class
M1-1Zoning
2,106 sfGross Floor Area
2Units
Rent Stabilized7 Open Violations ▸
Two family brick · 1,875 sf lot · 1.12 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
Roof1p · 1 filing · 12 docs
Floor 3Under Construction13p · 3 filings · 20 docs
Floor 2Under Construction12p · 3 filings · 20 docs
Floor 1Under Construction13p · 3 filings · 20 docs
CellarUnder Construction20p · 3 filings · 20 docs
Site & exterior11p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/04/2022$1.9M—ROCCO FERRIGNO TRUST → Private party$926/sf building
02/10/2014$1.5M—— → —$700/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TWIGCON LLC103/01/2026
EAB ENGINEERING PC612/27/2024
CHRISTOPHER TEETER211/16/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METAMECHANICS ARCHITECTURE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
M. INT'L ENGINEERING PLLCGeneral Contractor1203/21/2026
MR. AIR NYC CORPGeneral Contractor303/21/2026
CROSSFIELD PLBG.&HTGPlumbing207/08/2026
JJAW SERVICE INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EAB ENGINEERING, PC2048812/27/2024
Building Lifecycle
All (130)Filed (9)Permit Issued (8)Violation (9)Inspection (7)Objection (67)Special Inspection (30)
08/10/2026
Objection raised — Admin
07/28/2026
Objection raised — Scope
07/28/2026
Objection raised — Scope
07/28/2026
Objection resolved — Addressed
07/28/2026
Objection raised — Zoning
07/28/2026
Objection resolved — Addressed
05/27/2026
Permit issued — Structural
B01019967-I1-GC-CX
05/06/2026
Violation issued (HPD, open)
A
04/14/2026
Objection resolved — Resolved
04/14/2026
Objection resolved — Resolved
04/14/2026
Objection resolved — Resolved
04/14/2026
Objection resolved — Resolved
04/14/2026
Objection resolved — Resolved
04/14/2026
Objection resolved — Resolved
04/14/2026
Objection resolved — Resolved
04/14/2026
Objection resolved — Resolved
04/14/2026
Objection resolved — Resolved
04/14/2026
Special inspection requirement — Tenant Protection Plan Compliance
04/09/2026
Inspection — Pass-Final PL Permit Withdrawal
Pass
View inspection ↗
04/06/2026
Objection raised — Admin
04/06/2026
Objection raised — Admin
04/06/2026
Objection raised — Scope
04/06/2026
Objection raised — Fire_Protection
04/06/2026
Objection raised — Fire_Protection
04/06/2026
Objection raised — Fire_Protection
04/06/2026
Objection raised — Fire_Protection
04/06/2026
Objection raised — Fire_Protection
04/06/2026
Objection raised — Fire_Protection
04/03/2026
Inspection — Fail-Final PL Permit Withdrawal
Fail
View inspection ↗
03/26/2026
Objection resolved — Addressed
03/13/2026
Objection raised — Admin
03/01/2026
Filed — Alteration CO
NEW COMBINED SERVICE AND SPRINKLER DISTRIBUTION IN CONNECTION WITH ALT CO FILING
B01019967-S1
11/20/2025
Violation issued (HPD, open)
I
09/26/2025
Special inspection requirement — Sprinkler Systems
07/29/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/11/2025
Violation issued (HPD, open)
A
05/01/2025
Permit issued — Plumbing
B00933402-S1-PL
02/11/2025
Permit issued — Mechanical Systems
B01159733-I1-MS
01/22/2025
Objection resolved — Addressed
01/17/2025
Objection resolved — Addressed
01/17/2025
Objection resolved — Addressed
01/17/2025
Objection resolved — Addressed
01/17/2025
Objection resolved — Addressed
01/03/2025
Objection raised — Scope
01/03/2025
Objection raised — Mechanical
01/03/2025
Objection raised — Admin
01/03/2025
Objection raised — Inspections
12/27/2024
Filed — Alteration
INSTALL MINI SPLIT DUCTLESS SYSTEM CONDENSERS OUTSIDE IN THE REAR YARD AND ASSOCIATED AIR HANDLERS INSIDE CELLAR, 1-3 FLOORS IN CONJUNCTION WITH THE CONSTRUCTION APPLICATION #B01019667. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01159733-I1
12/24/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Iraj Issapour
12/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Iraj Issapour
12/24/2024
Special inspection requirement — Maintenance information
Iraj Issapour
12/24/2024
Special inspection requirement — HVAC-R and service water heating system controls
Iraj Issapour
12/24/2024
Special inspection requirement — HVAC-R and service water heating equipment
Iraj Issapour
12/24/2024
Special inspection requirement — Energy Code Compliance Inspections
Iraj Issapour
12/23/2024
Special inspection requirement — Final
Iraj Issapour
12/23/2024
Special inspection requirement — Mechanical Systems
Iraj Issapour
12/02/2024
Objection resolved — Addressed
12/01/2024
Objection resolved — Addressed
12/01/2024
Objection resolved — Addressed
11/29/2024
Violation issued (HPD, open)
I
Latest 60 of 130 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedJJAW SERVICE INC05/27/2026
DOB NOWPlumbingPermit IssuedCROSSFIELD PLBG.&HTG05/01/2025
DOB NOWMechanical SystemsPermit IssuedMR. AIR NYC CORP02/11/2025
DOB NOWStructuralPermit IssuedM. INT'L ENGINEERING PLLC10/22/2024
DOB NOWStructuralPermit IssuedM. INT'L ENGINEERING PLLC10/18/2024
DOB NOWStructuralPermit IssuedM. INT'L ENGINEERING PLLC05/20/2024
DOB NOWGeneral ConstructionPermit IssuedM. INT'L ENGINEERING PLLC01/19/2024
DOB NOWPlumbingPermit IssuedCROSSFIELD PLBG.&HTG12/11/2023
BISMHISSUEDJOSHUA CONSTRUCTION CORP05/23/2019
1 project · most recent 12/27/2024
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
12/27/2024Permit IssuedMR. AIR NYC CORPAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric MODEL: MUZ-FS09NA-U1, MUZ-FS15NA-U1, MXZ-3C24NAHZ4-U1, MXZ-3C30NAHZ4-U1 78,000 BTU · Condensing Unit ×4
Heating
Mitsubishi Electric MODEL: MUZ-FS09NA-U1, MUZ-FS15NA-U1, MXZ-3C24NAHZ4-U1, MXZ-3C30NAHZ4-U1 84,000 BTU · Heat Pump Outdoor ×4
1 project · most recent 03/01/2026
FiledStatusContractorScope
03/01/2026——32 heads
2 projects · most recent 03/01/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/01/2026———
11/16/2024Permit IssuedCROSSFIELD PLBG.&HTGGas, Storm, Water/Sanitary
4 projects · most recent 09/19/2024
General Wiring
FiledStatusContractorScope
09/19/2024Permit IssuedJ Y ELECTRIC INCGeneral Wiring
04/03/2024Permit IssuedJ Y ELECTRIC INCGeneral Wiring
12/20/2022Permit IssuedJ Y ELECTRIC INC—
06/17/2019CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
04/09/2026Pass-Final PL Permit WithdrawalPassView ↗
04/03/2026Fail-Final PL Permit WithdrawalFailView ↗
07/29/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/27/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/25/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/25/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/23/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 45
DateRequirementInspectorRole
04/14/2026Tenant Protection Plan Compliance—special
09/26/2025Sprinkler Systems—special
12/24/2024HVAC-R and service water piping design and insulationIraj Issapourenergy_progress
12/24/2024Fire-Resistant Penetrations and JointsIraj Issapourspecial
12/24/2024Maintenance informationIraj Issapourenergy_progress
12/24/2024HVAC-R and service water heating system controlsIraj Issapourenergy_progress
12/24/2024HVAC-R and service water heating equipmentIraj Issapourenergy_progress
12/24/2024Energy Code Compliance InspectionsIraj Issapourprogress
12/23/2024FinalIraj Issapourprogress
12/23/2024Mechanical SystemsIraj Issapourspecial
11/22/2024HVAC-R and service water piping design and insulationIraj Issapourenergy_progress
11/22/2024Fire-Resistant Penetrations and JointsIraj Issapourspecial
11/22/2024Energy Code Compliance InspectionsIraj Issapourprogress
11/22/2024HVAC-R and service water heating equipmentIraj Issapourenergy_progress
11/22/2024Maintenance informationIraj Issapourenergy_progress
11/22/2024HVAC-R and service water heating system controlsIraj Issapourenergy_progress
11/16/2024Air barrier - visual inspectionChristopher Teeterenergy_progress
11/16/2024Fenestration air leakageChristopher Teeterenergy_progress
11/16/2024Fenestration and door U-factor and product ratingsChristopher Teeterenergy_progress
11/16/2024Fenestration areasChristopher Teeterenergy_progress
10/09/2024FinalROMAN MARDAREWICHprogress
10/09/2024Fire-Resistance Rated ConstructionChristopher Teeterprogress
10/09/2024MeteringChristopher Teeterenergy_progress
10/09/2024Fire-Resistant Penetrations and JointsIraj Issapourspecial
10/09/2024Structural Stability – Alterations of existing buildingsIraj Issapourspecial
Latest 25 of 45.
▾Documents — 111 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/25/2026B00933402-I1Request digital key ↗
08/25/2026B00933402-S1Request digital key ↗
08/25/2026B00933402-P2Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION5
03/02/2022321925342Open ↗
01/27/2022321925342Open ↗
12/27/2021321925342Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
12/02/2019321925342Open ↗
12/02/2019321925342Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWRestrictive Declaration/Easement 16
08/25/2026B00933402-P2Open ↗
08/25/2026B00933402-S1Open ↗
08/14/2026B01019967-S1Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications55
▸DOB NOWProgress Inspector Seal & Signature33
09/14/2026B01019967-I1Open ↗
09/14/2026B01019967-I1Open ↗
09/14/2026B01019967-I1Open ↗
Showing 3 of 33 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/14/2026B01019967-I1Open ↗
09/14/2026B01019967-I1Open ↗
08/30/2026B00933402-P1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/25/2026B00933402-S1Open ↗
08/25/2026B00933402-P1Open ↗
08/23/2026B01159733-I1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
05/30/2019321925342Open ↗
05/15/2019321925342Open ↗
05/08/2019321925342Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
05/08/2019321925342Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/13/2026B01019967-I1Open ↗
08/13/2026B01019967-P1Open ↗
▸BISTenant Protection Plan and Notes1
04/16/2019321925342Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/25/2026B00933402-P2Open ↗
08/25/2026B00933402-S1Open ↗
08/23/2026B01159733-I1Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/08/2019321925342Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
05/30/2019321925342Open ↗
05/08/2019321925342Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
01/17/2022321925342Open ↗
01/17/2022321925342Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/17/2022321925342Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY2
02/06/2022321925342Open ↗
01/18/2022321925342Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
02/06/2022321925342Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/03/2022321925342Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT5
03/02/2022321925342Open ↗
02/28/2022321925342Open ↗
02/28/2022321925342Open ↗
Showing 3 of 5 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
02/06/2022321925342Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
05/08/2019321925342Open ↗
▸BISADDITIONAL INFORMATION1
09/25/2019321925342Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification2
08/18/2026B01019967-I1Open ↗
08/18/2026B01019967-P1Open ↗
▸DOB NOWWaiver Document1
08/13/2026B01019967-I1Open ↗