| Owner | Filings | Most Recent |
|---|---|---|
| Fourth Associates | 4 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Imc Architecture | 28 | 03/18/2026 |
| Skyline Rigging | 1 | 08/27/2024 |
| FL&M Engineering Design & Inspection | 2 | 08/05/2024 |
| Lombardo Professional Engineering | 1 | 06/25/2024 |
| Ashraf | 2 | 04/08/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| Core Consultants NYC | 28 | 03/21/2026 |
| KD Designs | 1 | 03/21/2026 |
| Millennium Designs of New York | 2 | 03/21/2026 |
| Lombardo Building Consultants | 2 | 03/21/2026 |
| Millennium Designs | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| M.N.C. General Contractors | General Contractor | 25 | 07/08/2026 |
| GWT Enterprises | Scaffold | 10 | 07/08/2026 |
| Best Mechanical Services | Plumbing | 8 | 07/08/2026 |
| M.N.C. General Contractors | Scaffold | 3 | 07/08/2026 |
| Imc Architecture | General Contractor | 3 | 03/22/2026 |
| Halcyon Construction Management | General Contractor | 3 | 03/21/2026 |
| Solas Electrical | Electrical | 2 | 03/22/2026 |
| Alba Services | Scaffold | 2 | 03/21/2026 |
| Halcyon Construction Management | Scaffold | 1 | 07/08/2026 |
| Edge Construction & Concrete | Scaffold | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Regional Testing | 394 | 19 | 03/18/2026 |
| Skyline Rigging | 7880 | 1 | 08/27/2024 |
| Fna Engineering Services | 7846 | 4 | 03/14/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | MNC General Contracting | 09/03/2025 |
| DOB NOW | Supported Scaffold | Signed-off | GWT Enterprises | 07/02/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | GWT Enterprises | 07/02/2025 |
| DOB NOW | Standpipe | Signed-off | Best Mechanical Services | 06/10/2025 |
| DOB NOW | Construction Fence | Signed-off | MNC General Contracting | 06/06/2025 |
| DOB NOW | Plumbing | Signed-off | Best Mechanical Services | 05/22/2025 |
| DOB NOW | Sprinklers | Signed-off | Best Mechanical Services | 05/22/2025 |
| DOB NOW | Curb Cut | Signed-off | MNC General Contracting | 05/21/2025 |
| DOB NOW | Standpipe | Signed-off | Best Mechanical Services | 05/20/2025 |
| DOB NOW | Mechanical Systems | Signed-off | MNC General Contracting | 03/03/2025 |
| DOB NOW | Suspended Scaffold | Signed-off | Doria | 08/27/2024 |
| DOB NOW | Foundation | Signed-off | MNC General Contracting | 08/05/2024 |
| DOB NOW | General Construction | Permit Issued | MNC General Contracting | 08/05/2024 |
| DOB NOW | Support of Excavation | Signed-off | MNC General Contracting | 08/05/2024 |
| DOB NOW | Structural | Signed-off | MNC General Contracting | 08/05/2024 |
| DOB NOW | Foundation | Signed-off | MNC General Contracting | 07/05/2024 |
| DOB NOW | Support of Excavation | Signed-off | MNC General Contracting | 07/05/2024 |
| DOB NOW | General Construction | Permit Issued | MNC General Contracting | 07/05/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | GWT Enterprises | 07/02/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | GWT Enterprises | 07/02/2024 |
| DOB NOW | Structural | Signed-off | MNC General Contracting | 06/26/2024 |
| DOB NOW | Protection and Mechanical Methods | Signed-off | Edge Construction & Concr | 06/25/2024 |
| DOB NOW | Standpipe | Signed-off | Best Mechanical Services | 06/07/2024 |
| DOB NOW | Sprinklers | Signed-off | Best Mechanical Services | 05/09/2024 |
| DOB NOW | Standpipe | Signed-off | Best Mechanical Services | 05/09/2024 |
| DOB NOW | Plumbing | Signed-off | Best Mechanical Services | 05/09/2024 |
| DOB NOW | Structural | Signed-off | MNC General Contracting | 04/09/2024 |
| DOB NOW | Construction Fence | Signed-off | MNC General Contracting | 03/15/2024 |
| DOB NOW | Foundation | Signed-off | MNC General Contracting | 03/08/2024 |
| DOB NOW | Mechanical Systems | Signed-off | MNC General Contracting | 02/15/2024 |
| DOB NOW | General Construction | Permit Issued | MNC General Contracting | 02/14/2024 |
| DOB NOW | Support of Excavation | Signed-off | MNC General Contracting | 02/14/2024 |
| DOB NOW | Construction Fence | Signed-off | Alba Services | 10/25/2023 |
| DOB NOW | Earth Work | Signed-off | Halcyon Construction Management | 05/13/2022 |
| DOB NOW | Construction Fence | Signed-off | Halcyon Construction Management | 05/13/2022 |
| BIS | PL | ISSUED | R.v.s.plumbing & Heating | 10/16/1997 |
| BIS | OT | ISSUED | H&H Laboratories | 06/23/1997 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 03/18/2026 | Permit Issued | M.N.C. General Contracting | Air Conditioning Systems, Heating Systems | Cooling Mitsubishi Electric PUZ-A18NKA7 18,000 BTU · Condensing Unit ×19 MXZ-SM36NAM 36,000 BTU · Condensing Unit ×15 SUZ-KA18NAHZ 21,600 BTU · Condensing Unit ×15 MXZ-SM36NAM2 36,000 BTU · Condensing Unit ×9 PUZ-A12NKA7 14,000 BTU · Condensing Unit ×7 MXZ-3C30NAHZ4 28,600 BTU · Condensing Unit ×6 SUZ-KA09NAHZ 12,500 BTU · Condensing Unit ×3 SUZ-KA15NAHZ 20,140 BTU · Heat Pump Outdoor ×3 MUZ-FS09NA 9,600 BTU · Condensing Unit ×2 MUZ-FS12NA 12,300 BTU · Condensing Unit ×1 MUZ-GS12NAHZ 18,100 BTU · Heat Pump Outdoor ×1 MXZ-2C20NAHZ4 25,500 BTU · Heat Pump Outdoor ×1 Heating Aaon RNA-025-C-A-8-AJBOC-B06ND 307,400 BTU · Ahu ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/18/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/18/2026 | Signed-off | Best Mechanical Services | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/24/2026 | Complete | Contact Electric | General Wiring |
| 02/12/2026 | Complete | Contact Electric | 84 meters, 84 new_meters |
| 10/23/2024 | Complete | KJK Electric | — |
| 07/11/2024 | Complete | Solas Electrical | — |
| 04/12/2024 | Complete | Contact Electric | — |
| 12/07/2023 | Complete | Solas Electrical | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/07/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 07/24/2025 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 06/16/2025 | Certified StandPipe-SD-Piping-Hydrostatic Test | Certified | View ↗ |
| 06/13/2025 | Certified StandPipe-SD-Fixtures-Finish-SD | Certified | View ↗ |
| 06/10/2025 | Certified StandPipe-Fire Pump (SD)-Fire Pump Test | Certified | View ↗ |
| 06/04/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 05/30/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 09/04/2024 | Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet) | Certified | View ↗ |
| 08/12/2024 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 06/28/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 06/28/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 05/22/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 05/17/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/23/2026 | Protection of exposed foundation insulation | Paul Raymond | energy_progress |
| 01/23/2026 | Fenestration air leakage | Paul Raymond | energy_progress |
| 01/23/2026 | Air barrier - visual inspection | Paul Raymond | energy_progress |
| 01/23/2026 | Fenestration and door U-factor and product ratings | Paul Raymond | energy_progress |
| 01/23/2026 | Exterior Insulation and Finish Systems (EIFS) | Paul Raymond | special |
| 01/23/2026 | Fire-Resistant Penetrations and Joints | Paul Raymond | special |
| 01/23/2026 | Wall Panels, Curtain Walls, and Veneers | Paul Raymond | special |
| 01/23/2026 | Energy Code Compliance Inspections | Paul Raymond | progress |
| 01/23/2026 | Fire-Resistance Rated Construction | Paul Raymond | progress |
| 01/23/2026 | Insulation placement and R values | Paul Raymond | energy_progress |
| 01/23/2026 | Air barrier continuity plan testing | Paul Raymond | energy_progress |
| 01/23/2026 | Air barrier — testing | Paul Raymond | energy_progress |
| 01/23/2026 | Vestibules | Paul Raymond | energy_progress |
| 01/23/2026 | Fenestration areas | Paul Raymond | energy_progress |
| 09/03/2025 | Standpipe Systems | Paul Raymond | special |
| 09/03/2025 | Sprinkler Systems | Paul Raymond | special |
| 09/03/2025 | Fire-Resistant Penetrations and Joints | Paul Raymond | special |
| 08/22/2025 | Insulation placement and R values | Paul Raymond | energy_progress |
| 08/22/2025 | Fenestration air leakage | Paul Raymond | energy_progress |
| 08/22/2025 | Air barrier - visual inspection | Paul Raymond | energy_progress |
| 08/22/2025 | Fenestration and door U-factor and product ratings | Paul Raymond | energy_progress |
| 08/22/2025 | Protection of exposed foundation insulation | Paul Raymond | energy_progress |
| 08/22/2025 | Vestibules | Paul Raymond | energy_progress |
| 08/22/2025 | Exterior Insulation and Finish Systems (EIFS) | Paul Raymond | special |
| 08/22/2025 | Fire-Resistant Penetrations and Joints | Paul Raymond | special |