Whole building & multi-floor projects1 filing
RoofSidewalk shed and pipe scaffolding installation3p · 2 filings
BulkheadSuspended scaffolds installation1p · 1 filing
Floor 8Temporary platform installation1 filing
Floor 7Temporary platform installation1 filing
Floor 6Temporary platform installation1 filing
Floor 5Temporary platform installation1 filing
Floor 4Temporary platform installation1 filing
Floor 3Temporary platform installation1 filing
Floor 2Temporary platform installation1 filing
Floor 1
Site & exteriorSidewalk shed and pipe scaffolding installation2 filings
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Fourth Associates403/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Imc Architecture2803/18/2026
Skyline Rigging108/27/2024
FL&M Engineering Design & Inspection208/05/2024
Lombardo Professional Engineering106/25/2024
Ashraf204/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Core Consultants NYC2803/21/2026
KD Designs103/21/2026
Millennium Designs of New York203/21/2026
Lombardo Building Consultants203/21/2026
Millennium Designs203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
M.N.C. General ContractorsGeneral Contractor2507/08/2026
GWT EnterprisesScaffold1007/08/2026
Best Mechanical ServicesPlumbing807/08/2026
M.N.C. General ContractorsScaffold307/08/2026
Imc ArchitectureGeneral Contractor303/22/2026
Halcyon Construction ManagementGeneral Contractor303/21/2026
Solas ElectricalElectrical203/22/2026
Alba ServicesScaffold203/21/2026
Halcyon Construction ManagementScaffold107/08/2026
Edge Construction & ConcreteScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Regional Testing3941903/18/2026
Skyline Rigging7880108/27/2024
Fna Engineering Services7846403/14/2024
Building Lifecycle
All (139)Filed (34)Permit Issued (35)Signed Off (14)Violation (10)Inspection (13)Special Inspection (30)Tax Incentive (3)
07/15/2026
421-a(16) construction completed
03/18/2026
Filed — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-A9
01/26/2026
Filed — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-A8
01/23/2026
Special inspection requirement — Insulation placement and R values
Paul Raymond
01/23/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Paul Raymond
01/23/2026
Special inspection requirement — Energy Code Compliance Inspections
Paul Raymond
01/23/2026
Special inspection requirement — Vestibules
Paul Raymond
01/23/2026
Special inspection requirement — Protection of exposed foundation insulation
Paul Raymond
01/23/2026
Special inspection requirement — Air barrier continuity plan testing
Paul Raymond
01/23/2026
Special inspection requirement — Fire-Resistance Rated Construction
Paul Raymond
01/23/2026
Special inspection requirement — Air barrier - visual inspection
Paul Raymond
01/23/2026
Special inspection requirement — Fenestration air leakage
Paul Raymond
01/23/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
Paul Raymond
01/23/2026
Special inspection requirement — Fenestration areas
Paul Raymond
01/23/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Paul Raymond
01/23/2026
Special inspection requirement — Air barrier — testing
Paul Raymond
01/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
09/18/2025
Signed off — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-S6
09/03/2025
Permit issued — General Construction
B00668047-I1-GC
09/03/2025
Special inspection requirement — Sprinkler Systems
Paul Raymond
09/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
09/03/2025
Special inspection requirement — Standpipe Systems
Paul Raymond
08/28/2025
Signed off — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-S5
08/25/2025
Filed — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-A7
08/22/2025
Special inspection requirement — Fenestration areas
Paul Raymond
08/22/2025
Special inspection requirement — Fire-Resistance Rated Construction
Paul Raymond
08/22/2025
Special inspection requirement — Air barrier continuity plan testing
Paul Raymond
08/22/2025
Special inspection requirement — Energy Code Compliance Inspections
Paul Raymond
08/22/2025
Special inspection requirement — Insulation placement and R values
Paul Raymond
08/22/2025
Special inspection requirement — Vestibules
Paul Raymond
08/22/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Paul Raymond
08/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Paul Raymond
08/22/2025
Special inspection requirement — Protection of exposed foundation insulation
Paul Raymond
08/22/2025
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
Paul Raymond
08/22/2025
Special inspection requirement — Air barrier — testing
Paul Raymond
08/22/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Paul Raymond
08/22/2025
Special inspection requirement — Air barrier - visual inspection
Paul Raymond
08/12/2025
Filed — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-A6
08/07/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/04/2025
Signed off — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-S1
08/04/2025
Signed off — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-S4
08/04/2025
Signed off — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-S2
07/30/2025
Signed off — Alteration
INSTALLATION OF 300 PSF SIDEWALK SHED, PIPE SCAFFOLDING, AND ROOF PROTECTION AS PER PLANS. ALL EQUIPMENT SHALL COMPLY WITH CHAPTER #33 OF THE 2022 CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01064923-I1
07/25/2025
Signed off — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-Z4
07/24/2025
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
07/23/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION PLYWOOD FENCE AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. FENCE SHALL COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2022.
B00948596-I1
07/02/2025
Permit issued — Supported Scaffold
B01064923-I1-SH
07/02/2025
Permit issued — Sidewalk Shed
B01064923-I1-SF
06/18/2025
Signed off — New Building
Sprinkler/Standpipe application in conjunction with New Building JOB NO#B00668047-I1
B00668047-Z3
06/16/2025
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
06/13/2025
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
06/10/2025
Permit issued — Standpipe
B00668047-S6-EW-SD
06/10/2025
Inspection — Certified StandPipe-Fire Pump (SD)-Fire Pump Test
Certified
View inspection ↗
06/06/2025
Permit issued — Construction Fence
B00948596-I1-FN
06/04/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
05/30/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
05/22/2025
Permit issued — Plumbing
B00668047-S5-PL
05/22/2025
Permit issued — Sprinklers
B00668047-S6-EW-SP
05/21/2025
Permit issued — Curb Cut
B00668047-Z4-CC
05/20/2025
Permit issued — Standpipe
B00668047-Z3-EW-SD
Latest 60 of 139 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMNC General Contracting09/03/2025
DOB NOWSupported ScaffoldSigned-offGWT Enterprises07/02/2025
DOB NOWSidewalk ShedSigned-offGWT Enterprises07/02/2025
DOB NOWStandpipeSigned-offBest Mechanical Services06/10/2025
DOB NOWConstruction FenceSigned-offMNC General Contracting06/06/2025
DOB NOWPlumbingSigned-offBest Mechanical Services05/22/2025
DOB NOWSprinklersSigned-offBest Mechanical Services05/22/2025
DOB NOWCurb CutSigned-offMNC General Contracting05/21/2025
DOB NOWStandpipeSigned-offBest Mechanical Services05/20/2025
DOB NOWMechanical SystemsSigned-offMNC General Contracting03/03/2025
DOB NOWSuspended ScaffoldSigned-offDoria08/27/2024
DOB NOWFoundationSigned-offMNC General Contracting08/05/2024
DOB NOWGeneral ConstructionPermit IssuedMNC General Contracting08/05/2024
DOB NOWSupport of ExcavationSigned-offMNC General Contracting08/05/2024
DOB NOWStructuralSigned-offMNC General Contracting08/05/2024
DOB NOWFoundationSigned-offMNC General Contracting07/05/2024
DOB NOWSupport of ExcavationSigned-offMNC General Contracting07/05/2024
DOB NOWGeneral ConstructionPermit IssuedMNC General Contracting07/05/2024
DOB NOWSidewalk ShedSigned-offGWT Enterprises07/02/2024
DOB NOWSidewalk ShedSigned-offGWT Enterprises07/02/2024
DOB NOWStructuralSigned-offMNC General Contracting06/26/2024
DOB NOWProtection and Mechanical MethodsSigned-offEdge Construction & Concr06/25/2024
DOB NOWStandpipeSigned-offBest Mechanical Services06/07/2024
DOB NOWSprinklersSigned-offBest Mechanical Services05/09/2024
DOB NOWStandpipeSigned-offBest Mechanical Services05/09/2024
DOB NOWPlumbingSigned-offBest Mechanical Services05/09/2024
DOB NOWStructuralSigned-offMNC General Contracting04/09/2024
DOB NOWConstruction FenceSigned-offMNC General Contracting03/15/2024
DOB NOWFoundationSigned-offMNC General Contracting03/08/2024
DOB NOWMechanical SystemsSigned-offMNC General Contracting02/15/2024
DOB NOWGeneral ConstructionPermit IssuedMNC General Contracting02/14/2024
DOB NOWSupport of ExcavationSigned-offMNC General Contracting02/14/2024
DOB NOWConstruction FenceSigned-offAlba Services10/25/2023
DOB NOWEarth WorkSigned-offHalcyon Construction Management05/13/2022
DOB NOWConstruction FenceSigned-offHalcyon Construction Management05/13/2022
BISPLISSUEDR.v.s.plumbing & Heating10/16/1997
BISOTISSUEDH&H Laboratories06/23/1997
1 project · most recent 03/18/2026
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
03/18/2026Permit IssuedM.N.C. General ContractingAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric PUZ-A18NKA7 18,000 BTU · Condensing Unit ×19
MXZ-SM36NAM 36,000 BTU · Condensing Unit ×15
SUZ-KA18NAHZ 21,600 BTU · Condensing Unit ×15
MXZ-SM36NAM2 36,000 BTU · Condensing Unit ×9
PUZ-A12NKA7 14,000 BTU · Condensing Unit ×7
MXZ-3C30NAHZ4 28,600 BTU · Condensing Unit ×6
SUZ-KA09NAHZ 12,500 BTU · Condensing Unit ×3
SUZ-KA15NAHZ 20,140 BTU · Heat Pump Outdoor ×3
MUZ-FS09NA 9,600 BTU · Condensing Unit ×2
MUZ-FS12NA 12,300 BTU · Condensing Unit ×1
MUZ-GS12NAHZ 18,100 BTU · Heat Pump Outdoor ×1
MXZ-2C20NAHZ4 25,500 BTU · Heat Pump Outdoor ×1
Heating
Aaon RNA-025-C-A-8-AJBOC-B06ND 307,400 BTU · Ahu ×1
1 project · most recent 03/18/2026
Sprinkler System
FiledStatusContractorScope
03/18/2026——Sprinkler System
1 project · most recent 03/18/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/18/2026Signed-offBest Mechanical ServicesGas, Storm, Water/Sanitary
6 projects · most recent 04/24/2026
General Wiring
FiledStatusContractorScope
04/24/2026CompleteContact ElectricGeneral Wiring
02/12/2026CompleteContact Electric84 meters, 84 new_meters
10/23/2024CompleteKJK Electric—
07/11/2024CompleteSolas Electrical—
04/12/2024CompleteContact Electric—
12/07/2023CompleteSolas Electrical—
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
08/07/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/24/2025Pass-Final Curb Cut Non-Directive 14PassView ↗
06/16/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
06/13/2025Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
06/10/2025Certified StandPipe-Fire Pump (SD)-Fire Pump TestCertifiedView ↗
06/04/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/30/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/04/2024Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
08/12/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/28/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/28/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/22/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/17/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 111
DateRequirementInspectorRole
01/23/2026Protection of exposed foundation insulationPaul Raymondenergy_progress
01/23/2026Fenestration air leakagePaul Raymondenergy_progress
01/23/2026Air barrier - visual inspectionPaul Raymondenergy_progress
01/23/2026Fenestration and door U-factor and product ratingsPaul Raymondenergy_progress
01/23/2026Exterior Insulation and Finish Systems (EIFS)Paul Raymondspecial
01/23/2026Fire-Resistant Penetrations and JointsPaul Raymondspecial
01/23/2026Wall Panels, Curtain Walls, and VeneersPaul Raymondspecial
01/23/2026Energy Code Compliance InspectionsPaul Raymondprogress
01/23/2026Fire-Resistance Rated ConstructionPaul Raymondprogress
01/23/2026Insulation placement and R valuesPaul Raymondenergy_progress
01/23/2026Air barrier continuity plan testingPaul Raymondenergy_progress
01/23/2026Air barrier — testing Paul Raymondenergy_progress
01/23/2026VestibulesPaul Raymondenergy_progress
01/23/2026Fenestration areasPaul Raymondenergy_progress
09/03/2025Standpipe SystemsPaul Raymondspecial
09/03/2025Sprinkler SystemsPaul Raymondspecial
09/03/2025Fire-Resistant Penetrations and JointsPaul Raymondspecial
08/22/2025Insulation placement and R valuesPaul Raymondenergy_progress
08/22/2025Fenestration air leakagePaul Raymondenergy_progress
08/22/2025Air barrier - visual inspectionPaul Raymondenergy_progress
08/22/2025Fenestration and door U-factor and product ratingsPaul Raymondenergy_progress
08/22/2025Protection of exposed foundation insulationPaul Raymondenergy_progress
08/22/2025VestibulesPaul Raymondenergy_progress
08/22/2025Exterior Insulation and Finish Systems (EIFS)Paul Raymondspecial
08/22/2025Fire-Resistant Penetrations and JointsPaul Raymondspecial
Latest 25 of 111.
▾Documents — 294 on file (BIS + DOB NOW)
▸Plans & Drawings34
▸DOB NOWPlans/Sketch34
08/29/2026B00668047-A9Request digital key ↗
08/29/2026B00668047-A8Request digital key ↗
08/29/2026B00668047-A7Request digital key ↗
Showing 3 of 34 on file for this type
▸Applications & Permits8
▸DOB NOWHPD - Permit Notice5
08/29/2026B00668047-I1Open ↗
08/13/2026B00668047-A4Open ↗
08/13/2026B00668047-P4Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
09/05/2025340839748Open ↗
07/11/2024300647147Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
06/07/2024340839748Open ↗
▸Zoning, Tax Lot & Property Records15
▸DOB NOWZD1: DOB Zoning Diagram7
08/13/2026B00668047-P4Open ↗
08/13/2026B00668047-I1Open ↗
08/13/2026B00668047-P8Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWZoning Exhibit form (1-5)7
08/13/2026B00668047-P4Open ↗
08/13/2026B00668047-I1Open ↗
08/13/2026B00668047-A9Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications138
▸DOB NOWProgress Inspector Seal & Signature75
09/02/2026B00668047-A4Open ↗
09/02/2026B00668047-A4Open ↗
09/02/2026B00668047-A4Open ↗
Showing 3 of 75 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature34
08/29/2026B00668047-P1Open ↗
08/29/2026B00668047-A8Open ↗
08/29/2026B00668047-A7Open ↗
Showing 3 of 34 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature28
09/23/2026B00668047-A2Open ↗
09/23/2026B00668047-A2Open ↗
09/02/2026B00668047-A4Open ↗
Showing 3 of 28 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
04/12/2022340839748Open ↗
▸Trade Schedules & Equipment7
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸Safety & Tenant Protection14
▸DOB NOWStreet Tree Checklist7
08/29/2026B00668047-A8Open ↗
08/29/2026B00668047-A7Open ↗
08/29/2026B00668047-I1Open ↗
Showing 3 of 7 on file for this type
▸BISSTREET TREE CHECKLIST2
06/07/2024340839748Open ↗
04/12/2022340839748Open ↗
▸BISSTREET TREE SUPPORTING DOCUMENT1
06/07/2024340839748Open ↗
▸BISBPP: STREET TREES SITE PLAN1
04/12/2022340839748Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWStreet Trees Site Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWStreet Tree Sign Off1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos43
▸DOB NOWOER: Notice to Proceed31
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 31 on file for this type
▸DOB NOWOER: Notice of Satisfaction11
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 11 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
06/07/2024340839748Open ↗
▸Energy Compliance3
▸DOB NOWPreliminary Commissioning Report Certification2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWEN2: As Built Energy Analysis1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
07/21/2025340839748Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/12/2022340839748Open ↗
▸Other Documents30
▸DOB NOWProperty Ownership Certification9
08/29/2026B00668047-A8Open ↗
08/29/2026B00668047-A4Open ↗
08/29/2026B00668047-A7Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸DOB NOWSite Survey: Initial7
08/13/2026B00668047-P8Open ↗
08/13/2026B00668047-P4Open ↗
08/13/2026B00668047-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWAdjoining Owners Notification3
08/13/2026B00668047-S9Open ↗
08/13/2026B00668047-S1Open ↗
08/13/2026B00668047-S3Open ↗
▸DOB NOWFinal Survey1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸DOB NOWCalculations1
08/13/2026B01102353-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026B00668047-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026B01102353-I1Open ↗