← Back
BuildNYC
Three families
3301 BARKER AVENUE
BRONX · BIN 2056856
💬 Discuss this project
1910Year Built
2.75Stories
C0Building Class
R5AZoning
2,468 sfGross Floor Area
3Units
Rent Stabilized1 Active Violation ▸FDNY Report ↗
Three families · Owner of record: HR Barker · 2,000 sf lot · 1.23 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 31 filing · 5 docs
Floor 2
Floor 1
CellarPlumbing alteration4p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC Department of Housing Preservation and Development403/21/2026
HR Barker203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/14/2022$950K—Private party → HR BARKER LLC$385/sf building
02/09/2018$645K—BEST TO PURCHASE REALTY 2016,INC., → Private party$261/sf building
03/13/2017$280K—Private party → BEST TO PURCHASE REALTY 2016 INC$113/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Edward C. Hicks RA304/17/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Premium Expediting Services303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Elite GC NYGeneral Contractor303/21/2026
Gateway DemolitionGeneral Contractor203/21/2026
Austin Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP Concrete Testing and I6252103/30/2022
Building Lifecycle
11/16/2023
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · closed
06/21/2023
Signed off — Alteration
PROPOSED INSTALLATION OF 3 COMBINATION GAS BOILERS AND REMOVAL OF (1) OIL BOILER WITH STORAGE TANK AND (1) HOT WATER HEATER.
X00773890-I1
04/18/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/18/2023
Special inspection requirement — Energy Code Compliance Inspections
EDWARD HICKS
04/17/2023
Filed — Alteration
PROPOSED INSTALLATION OF 3 COMBINATION GAS BOILERS AND REMOVAL OF (1) OIL BOILER WITH STORAGE TANK AND (1) HOT WATER HEATER.
X00773890-P1
147 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAustin Plumbing & Heating08/05/2022
DOB NOWGeneral ConstructionSigned-offElite GC NY04/23/2022
BISEQISSUEDGateway Demo/Civil01/07/2013
BIS—ISSUEDGateway Demo/Civil01/07/2013
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
04/18/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/14/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/23/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/12/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/12/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/17/2022Pass-Final General Construction Non-Directive 14PassView ↗
05/12/2022Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/18/2023Energy Code Compliance InspectionsEDWARD HICKSprogress
04/15/2023Energy Code Compliance InspectionsEDWARD HICKSprogress
03/30/2022Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
03/30/2022Energy Code Compliance InspectionsEDWARD HICKSprogress
03/30/2022Fire-Resistance Rated ConstructionEDWARD HICKSprogress
33 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account