ECB02/09/2026VACATED ORDER ISN'T VISIBLE AND WAS REMOVED, COMPLY WITH CODE; COMPLY WITH CODE$5K due
ECB02/05/2026UNLAWFUL ACTS.FAILURE TO COMPLY WITH A VACATE ORDER OF THE COMMISSIONER'S ORDER.AS NOTED:AT THE TIME OF INSPECTION THERE WERE NO VACATE ORDER POSTED ON DOOR TO AREA THAT NEEDED VACATING OR ON MAIN ENTRANCE DOOR$2K due
DOB02/05/2026EWO DUE TO IMMINENT HAZARDOUS CONDITION ON EXP1 SW END OF PARAPET WALL WHERE COPING STONE IS DISINTEGRATING & INADEQUATE PROTECTION IS PROVID ADDITIONAL PROTECTION IS REQUIRED THAT SHOULD EXTEND BEYOND PROPERTY LINE BY 5' BULGING & LOOSE BRICKS ON EXP3 N ELEV,EXP4 E ELEV.REMEDY: OWNER TO PROVIDE ADDITIONAL PROTECTION SAFE MEAS TO SECURE PUBLIC.+
DOB02/05/2026FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AS NOTED AT TH E TIME OF INSPECTION,I OBSERVED ON EXP1 SOUTH ELEV,SPALLING,DISINTERGR ATING COPING STONE ON PARAPET.EXP3&4 NORTH & WEST ELEV:BULGING,LOOSE B RICKS AT MULTIPLE LOCATIONS & PARAPET.ROOF:CRACKS IN BULKHEAD MASONRY WORK.REMEDY:REPAIR AND/OR REPLACE ALL DAMAGE,DEFECTIVE MASONRY FACADE
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
DOB02/21/2025PARTIAL VACATE ORDER DUE TO MULTIPLE HAZARDOUS CONDITIONS SUCH AS BULG CRACKED & SPALLING MASONRY BRICK AT PARAPET BUILDING FACADE. THESE CONDITIONS HAVE THEREFORE MADE 4FL TERRACE EXP#2 W & 3 NORTH AND REAR YARD THE 2FL ROOF SET BACK N EXP#3 UNABLE TO OCCUPY.REMEDY: VACATE 4FL TERRACES @ EXPS 2 W & NORTH REAR YARD THE 2FL ROOF SETBACK S EXP#3
DOB10/30/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/12/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED @ EXP#S (3&4) NORTH/EAST ELEV DETERIORATING MASONRY; SPALLED/SPALLING STUCCO; DAMAGED MORTAR JOINTS;CRACKS @MASONRY&DAMAGED WINDOWS. ALSO OBSERVED BULGING MASONRON SECTION @ PARAPET LEVEL ON EXP#4(E.ELEV) REMEDY: FIX AND/OR REPLACE
ECB08/29/2024FAILURE TO MAINTAIN BUILDING FACADE AND APPURTENANCES. OBSERVED DETERIORATING MASONRY AND SPALLING/SPALLED STUCCO AT EXPOSURES 3 AND 4(NORTHAND EAST ELEVATION). ALSO SPALLING STUCCO ON BULKHEAD. REMEDY: MAINTAI$12K due
ECB02/01/2024FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #803250.AGG2 HISTORY OF NONCOMPLIANCE ON 370221$6K due
ECB09/12/2023AT THE TIME OF MY INSPECTION I OBSERVED SIDEWALK SHED IN-PLACE AT EXPOSURE 1 WITH NO INFORMATION SIGN / OR CONTACT INFORMATION POSTED AS REQUIRED BC 3301.9. ECB VIOLATION ISSUED.$6K due
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
ECB12/22/2022FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#903250.REMEDY:SUBMIT ACCEPTABLE REQUIRE$1K due
DOB02/22/2022FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
DOB11/14/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB10/17/2018V-DOB VIOLATION - ACTIVE
DOB05/31/2018FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
DOB01/26/2018VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
DOB11/14/2016VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
DOB06/10/2015VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB10/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
DOB01/31/2013FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
ECB12/29/2011FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT.REM: 36016912N FILE AN AMENDED RPT FOLLOWING REMEDIAL$-2,000 due
DOB03/31/2008V-DOB VIOLATION - ACTIVE
DOB11/19/2004V-DOB VIOLATION - ACTIVE
DOB04/21/2004V-DOB VIOLATION - ACTIVE
DOB02/13/2004V-DOB VIOLATION - ACTIVE
DOB03/21/2003V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
DOB08/08/2002V-DOB VIOLATION - ACTIVE
DOB03/26/2002V-DOB VIOLATION - ACTIVE
DOB02/19/2002V-DOB VIOLATION - ACTIVE
DOB03/08/2001V-DOB VIOLATION - ACTIVE
DOB02/27/2001V-DOB VIOLATION - ACTIVE
DOB03/10/2000V-DOB VIOLATION - ACTIVE
DOB02/07/2000V-DOB VIOLATION - ACTIVE
DOB03/16/1999V-DOB VIOLATION - ACTIVE
DOB01/06/1998V-DOB VIOLATION - ACTIVE
DOB09/16/1997V-DOB VIOLATION - ACTIVE
DOB07/01/1997V-DOB VIOLATION - ACTIVE
DOB02/10/1997V-DOB VIOLATION - ACTIVE
DOB07/01/1992V-DOB VIOLATION - ACTIVE
HPD07/25/1990D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WATCHMAN CLOCK.
HPD07/25/1990§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD PARTITION AND DOOR INSTALLED 1 STY NORTH ROOM TO EAST FIRE STAIR TO CELLAR.
HPD07/25/1990§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER 4 STY WEST BULKHEAD CEILING.
HPD07/25/1990§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR 6 TY FRONT EAST FIRE STAIRS.
HPD07/25/1990§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING 1 STY PUBLIC HALL.
HPD07/25/1990D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS 3 STY WEST FIRE STAIRS.
ECB04/20/2026FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #803250. AGG2 HISTORY OF NONCOMPLIANCE ON 37026Hearing held — result not yet published$6K proposed
ECB11/22/2023PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. SWS ERECTED AT EXP 1 IN UNSAFE CONDITION (3307.6.5.1), ROTTEN MUDSILLS AT FRONT OF SHED ADJACENT TO CURB. ALSO MISSING PROJECT INFO PANEL CONSTRUCTION SINothing owed — awaiting certificate of correction
ECB11/24/2021FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #803250.REMEDY:FILE ACCEPTABLE REPORT.Nothing owed — awaiting certificate of correction
ECB10/17/2018FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE. NOTED AT TIME OF INSPEC TION NORTH ELEVATION EXP#3 DISPLACED/BULGING MASONRY BRICK ON EXTERIOROF PARAPET ABOVE 7TH FLOOR WINDOW ON WEST SIDE EAST ELEVATION EXPOSURENothing owed — awaiting certificate of correction
ECB08/23/2018FAILURE TO MAINTAIN BLDG EXTERIOR WALLS/FACADES & APPURTENANCES. SOUTH ELEVATION EXP#1: BROKEN GLASS WINDOW @ 5TH & 6TH FLR, VERTICAL CRACK @ SOUTH EAST CORNER 1ST FLR, MISSING STONE & CRACK OVER ENTRANCE DOOR.Nothing owed — awaiting certificate of correction
ECB07/27/2018FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#803250. REMEDY: SUBMIT REQUIRED TECHNICAL REPORTNothing owed — awaiting certificate of correction
ECB11/28/2011LOCAL LAW 6TH CYCLE REPORT FAILED AS UNSAFE BY ARCHITECT/ENGINEER NO AMENDED REPORT WAS FILED AS PER 27-129D & 1RCNY 32-03B5I NO SIDEWALK SHED FENCE NETTING OR STREET CLOSURE WAS OBSERVED REM: PROVIDE FOR SAFETNothing owed — awaiting certificate of correction
ECB08/15/2011FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. 36015507P. REMEDY: FILE AN AMENDED REPORT FOLLNothing owed — awaiting certificate of correction
ECB03/29/2011FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT.INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. REMEDY: FILE AN AMENDED REPORT FOLLOWING REMEDIAL RENothing owed — awaiting certificate of correction
ECB01/06/2011FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. 36010365X. REMEDY: FILE AN AMENDED REPORT FOLLOWINGNothing owed — awaiting certificate of correction
ECB07/22/2010FAILURE TO FILE AN ARCHITECT ENGINEER REPORT CERTIFYING EXIT DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURCE STORAGE BATTERY EQUIPMENT REM: FILE ARCHITECT/ENGINEER REPORTNothing owed — awaiting certificate of correction
ECB02/12/2010FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT.INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT REMEDY:FILE AN AMENDED REPORT FOLLOWING REMEDIAL REPANothing owed — awaiting certificate of correction
ECB06/30/2009FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPARTMETN INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. REM: FILE AN AMENDED REPORT FOLLOWING REMEDIALNothing owed — awaiting certificate of correction
ECB02/20/2009FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. REMEDY: FILE AN AMENDED REPORT FOLLOWING REMEDIANothing owed — awaiting certificate of correction
ECB05/28/2008FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. REMEDY: FILE AN AMENDED REPORT FOLLOWING REMEDIANothing owed — awaiting certificate of correction
ECB06/21/2004FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPRURTENANCES AS REQUIRED BY LOCAL LAW 11 OF 1998 AND THE DEPARTMENT OF BUILDINGS RULES AND REGULATIONS.REMEDY:FILE THNothing owed — awaiting certificate of correction
ECB03/09/2004FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY LOCAL LAW 11 OF 1998AND THE DEPARTMENT OF BUILDINGS RULES AND REGULATIONS.REMEDY:FILE THENothing owed — awaiting certificate of correction
ECB07/11/200073X11-RETURN DEVICE #1P3013 BACK TO SERVICESO PROPER INSPECTION CAN BEPERFORMED BY THIS DEPARTMENT.Nothing owed — awaiting certificate of correction
ECB10/13/199973I. ENTIRE DEVICE IS NOT WORKABLE, REPAIR OR FILE DISMANTLE.Nothing owed — awaiting certificate of correction
ECB05/20/199846H39H 49 H-HOIST CABLES EXCESSIVE CROWN WEAR.Nothing owed — awaiting certificate of correction