| Owner | Filings | Most Recent |
|---|---|---|
| USA INC BUILDERS GROUP | 1 | 03/22/2026 |
| 3537 BAINBRIDGE REALTY LL | 1 | 03/22/2026 |
| AFS SYSTEMS | 6 | 03/21/2026 |
| SHG EQUITIES | 2 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 01/05/2023 | $2.1M | — | ROMAN CATHOLIC CHURCH OF SAINT BRENDAN AND SAINT → 3537 BAINBRIDGE REALTY LLC | $246/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| CHUN ENGINEERING CONSULTANT PLLC | 15 | 07/01/2026 |
| M.INT'L ENGINEERING PLLC | 10 | 03/15/2024 |
| MOHAMMAD AHEAD, PE | 1 | 09/08/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| EXPRESS FILING INC | 36 | 03/21/2026 |
| EMPIRE EXPEDITING | 10 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| JSB WORKS INC | General Contractor | 15 | 07/08/2026 |
| BUILDERS GROUP USA INC | General Contractor | 8 | 07/08/2026 |
| PRIME PIPING & HEATING IN | Fire Protection | 1 | 07/08/2026 |
| DYNAMIX SCAFFOLD GROUP LL | General Contractor | 1 | 07/08/2026 |
| A. M. PLUMBING COMPANY | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HRF SERVICES CORP | 5616 | 20 | 07/01/2026 |
| M. INT'L ENGINEERING PLLC | 3129 | 4 | 09/11/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Signed-off | BUILDERS GROUP USA | 02/08/2024 |
| DOB NOW | General Construction | Permit Issued | BUILDERS GROUP USA | 01/02/2024 |
| DOB NOW | Construction Fence | Signed-off | BUILDERS GROUP USA | 11/29/2023 |
| DOB NOW | General Construction | Permit Issued | BUILDERS GROUP USA | 11/28/2023 |
| DOB NOW | Mechanical Systems | Signed-off | BUILDERS GROUP USA | 11/28/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | DYNAMIX SCAFFOLD GROUP LL | 09/11/2023 |
| DOB NOW | General Construction | Permit Issued | JSB WORKS INC | 07/18/2023 |
| DOB NOW | General Construction | Permit Issued | JSB WORKS INC | 05/16/2023 |
| DOB NOW | Structural | Signed-off | JSB WORKS INC | 05/16/2023 |
| DOB NOW | Foundation | Signed-off | JSB WORKS INC | 05/10/2023 |
| DOB NOW | Sprinklers | Signed-off | A M B MECHANICAL INC | 05/03/2023 |
| DOB NOW | Plumbing | Signed-off | A. M. PLUMBING COMPANY | 04/24/2023 |
| DOB NOW | Mechanical Systems | Signed-off | JSB WORKS INC | 04/18/2023 |
| DOB NOW | Construction Fence | Signed-off | JSB WORKS INC | 12/27/2022 |
| DOB NOW | Foundation | Signed-off | JSB WORKS INC | 05/31/2022 |
| BIS | EQ | ISSUED | CHESAKL ENTERPRISES INC | 07/14/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/01/2026 | Signed-off | BUILDERS GROUP USA INC | Heating and Air Conditioning Systems | Heat / Cool Daikin FTXS12LVJU 12,000 BTU · Fan Coil Indoor ×88 RX12BXVJU 11,300 BTU · Fan Coil Indoor ×84 2MXS18WMVJU9 25,000 BTU · Fan Coil Indoor ×2 4MXS36WMVJU9 43,000 BTU · Fan Coil Indoor ×2 CTXS07LVJU 7,000 BTU · Fan Coil Indoor ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/01/2026 | Signed-off | PRIME PIPING & HEATING IN | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/01/2026 | Signed-off | A. M. PLUMBING COMPANY | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/14/2025 | Complete | S&R ELECTRICAL & MECHANIC | General Wiring |
| 06/24/2025 | Complete | S&R ELECTRICAL & MECHANIC | General Wiring |
| 01/27/2025 | Complete | FRIED ELECTRIC CO. | General Wiring |
| 12/25/2024 | Complete | PLATINUM PWR ELECTL CONT | General Wiring |
| 09/13/2023 | Complete | HIGH QUALITY ELECTRIC OF | — |
| 07/12/2018 | Complete | POWERONE ELECT'L CONTRG | 1 meters, 1 new_meters |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/01/2026 | Signed-off | BUILDERS GROUP USA INC | Steel |
| 09/11/2023 | Signed-off | JSB WORKS INC | 3 scope_items |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/01/2026 | Signed-off | BUILDERS GROUP USA INC | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/29/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/18/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 04/16/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 04/04/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/28/2024 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 03/15/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 01/31/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 01/08/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/29/2023 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 11/01/2023 | Pass-Final PL - Underground | Pass | View ↗ |
| 07/07/2023 | Pass-Final PL - Underground | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/17/2026 | Metering | FAHAD FATEH | energy_progress |
| 07/17/2026 | Lighting in dwelling units | FAHAD FATEH | energy_progress |
| 07/17/2026 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 07/17/2026 | Exterior lighting power | FAHAD FATEH | energy_progress |
| 07/17/2026 | Lighting controls | FAHAD FATEH | energy_progress |
| 07/17/2026 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 07/17/2026 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 07/17/2026 | Fenestration areas | FAHAD FATEH | energy_progress |
| 07/17/2026 | Structural Stability – Alterations of existing buildings | FAHAD FATEH | special |
| 07/17/2026 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 07/17/2026 | Interior lighting power | FAHAD FATEH | energy_progress |
| 07/17/2026 | Preliminary | FAHAD FATEH | progress |
| 07/17/2026 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 07/17/2026 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 07/17/2026 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 07/17/2026 | Maintenance information | FAHAD FATEH | energy_progress |
| 06/29/2026 | Maintenance information | FAHAD FATEH | energy_progress |
| 06/29/2026 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 06/29/2026 | Metering | FAHAD FATEH | energy_progress |
| 06/29/2026 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 06/29/2026 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 06/29/2026 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 06/29/2026 | Interior lighting power | FAHAD FATEH | energy_progress |
| 06/29/2026 | Fenestration areas | FAHAD FATEH | energy_progress |
| 06/29/2026 | Lighting controls | FAHAD FATEH | energy_progress |