← Back
Three families
355 CLINTON STREET
BROOKLYN · BIN 3003930
💬 Discuss this project
1879Year Built
3Stories
C0Building Class
R6Zoning
—Gross Floor Area
3Units
0 Open Violations
Three families · Owner of record: 355 CLINTON LLC · 2.27 FAR built · Flood zone X
Locations of Work
Structural
Floor 11p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
355 CLINTON LLC203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASE PLLC107/29/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JON PAUL DESIGN & CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DIPIERRO ACTION CONSTR COGeneral Contractor203/21/2026
OSWALD IEN, OElectrical103/21/2026
QUINTANILLA, RAMIROElectrical103/21/2026
Y.R. CONTRACTING LLCElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASE ENGINEERING PLLC5785107/29/2022
Building Lifecycle
All (17)Filed (1)Permit Issued (1)Signed Off (1)Violation (5)Objection (2)Special Inspection (7)
02/19/2025
Signed off — Alteration
STRUCTURAL WORK ASSOCIATED WITH REPLACEMENT OF EX. REAR DECK W/NEW STEEL DECK, & ADDITION OF NEW STEEL STAIR OVER STEEL DUNNAGE AT ROOF. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
B00680278-I1
05/28/2024
Permit issued — Structural
B00680278-I1-ST
07/24/2023
Violation issued (ECB, closed)
Construction
08/09/2022
Objection raised — Scope
08/09/2022
Objection resolved — Addressed
07/29/2022
Filed — Alteration
STRUCTURAL WORK ASSOCIATED WITH REPLACEMENT OF EX. REAR DECK W/NEW STEEL DECK, & ADDITION OF NEW STEEL STAIR OVER STEEL DUNNAGE AT ROOF. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
B00680278-I1
06/13/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
alon egozi
02/14/2022
Special inspection requirement — Post-installed Anchors
alon egozi
02/14/2022
Special inspection requirement — Subgrade Inspections
alon egozi
02/14/2022
Special inspection requirement — Concrete - Cast-In-Place
alon egozi
02/14/2022
Special inspection requirement — Structural Steel - Details
alon egozi
02/14/2022
Special inspection requirement — Final
alon egozi
02/14/2022
Special inspection requirement — Structural Cold-Formed Steel
alon egozi
03/10/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/1988
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/29/1987
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/29/1987
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offDIPIERRO ACTION CONSTR05/28/2024
BIS—ISSUEDDIPIERRO ACTION CONSTR CO05/11/2023
BIS—ISSUEDDIPIERRO ACTION CONSTR CO09/09/2022
BISPLISSUEDALIENT PLBG & HTG INC06/06/2016
BISMHISSUEDPALONE BROTHERS AIR05/18/2016
BISOTISSUEDINTERMASTER CORP03/03/2016
BISPLISSUEDALJER PLBG & HTG CORP05/05/2003
BISOTISSUEDM & D CONSTRUCTION CO02/11/2003
1 project · most recent 03/19/2019
FiledStatusContractorScope
03/19/2019CompleteANTONIO CERIELLO ELEC INC2 meters, 2 new_meters
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
06/13/2022Structural Stability – Alterations of existing buildingsalon egozispecial
02/14/2022Post-installed Anchorsalon egozispecial
02/14/2022Subgrade Inspectionsalon egozispecial
02/14/2022Concrete - Cast-In-Placealon egozispecial
02/14/2022Structural Steel - Detailsalon egozispecial
02/14/2022Finalalon egoziprogress
02/14/2022Structural Cold-Formed Steelalon egozispecial
▾Documents — 68 on file (BIS + DOB NOW)
▸Applications & Permits18
▸BISPLAN / WORK APPROVAL APPLICATION12
06/30/2025340751216Open ↗
07/15/2024340751216Open ↗
07/11/2024340751216Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION4
09/16/2022340751216Open ↗
06/07/2016321236541Open ↗
05/18/2016321236541Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
03/10/2025340751216Open ↗
▸DOB NOWLPC Approval/Permit1
08/13/2026B00680278-I1Open ↗
▸Seals & Professional Certifications11
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
06/08/2018321763043Open ↗
03/03/2016321236541Open ↗
02/12/2016321236541Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/30/2026B00680278-I1Open ↗
08/30/2026B00680278-I1Open ↗
08/30/2026B00680278-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/27/2020340751216Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/27/2020340751216Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B00680278-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/30/2026B00680278-I1Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
06/08/2018321763043Open ↗
09/17/2015321236541Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
09/14/2023321236541Open ↗
▸BISRPZ/DDCV TEST REPORT : GEN215B1
02/10/2016321236541Open ↗
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
09/14/2023321236541Open ↗
▸Safety & Tenant Protection3
▸BISTENANT PROTECTION PLAN AND NOTES2
10/27/2020340751216Open ↗
06/08/2018321763043Open ↗
▸BISSTREET TREE CHECKLIST1
09/17/2015321236541Open ↗
▸Environmental & Asbestos3
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/27/2020340751216Open ↗
09/17/2015321236541Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B00680278-I1Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
09/11/2023321236541Open ↗
08/05/2023321236541Open ↗
08/05/2023321236541Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/08/2018321763043Open ↗
09/17/2015321236541Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
09/14/2023321236541Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/27/2020340751216Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY4
09/11/2023321236541Open ↗
08/05/2023321236541Open ↗
09/06/2022340751216Open ↗
Showing 3 of 4 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
09/14/2023321236541Open ↗
▸BISMECHANICAL SYSTEMS1
09/14/2023321236541Open ↗
▸Approvals, Objections & Sign-offs5
▸BISFINAL2
09/14/2023321236541Open ↗
09/14/2023321236541Open ↗
▸BISLANDMARKS SIGNOFF1
09/15/2023321236541Open ↗
▸BISSCHEDULE A - OCCUPANCY - USE1
10/27/2020340751216Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/15/2023321236541Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT3
10/27/2020340751216Open ↗
06/08/2018321763043Open ↗
09/17/2015321236541Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
09/14/2023321236541Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET2
06/08/2018321763043Open ↗
09/17/2015321236541Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/27/2020340751216Open ↗
▸BISADDITIONAL INFORMATION1
09/13/2023321236541Open ↗
▸Other Documents1
▸BISHVAC & SERVICE WATER PIPING DESIGN AND INSULATION1
09/14/2023321236541Open ↗