HPD06/02/2026567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT RATS AT BUILDING FRONT YARD
ECB03/25/2025WEILMCLAIN GAS STEAM BOILER IS UNREGISTERED W/DOB+UNUSED OIL TANKS NOTLEGALLY ABANDONED+NO FRESH AIR IN BOILER ROOM+LOOSE CEMENT@CHIMNEY+CHIMNEY CLEANOUT IS INOPERABLE+SAFETY VALVE NOT PIPED DOWN, MAINTAIN BOIL$1K due
ECB03/25/2025IN BOILER ROOM GAS HWH#1 HAS BEEN REMOVED WITHOUT CAPPING FLUE TO CHIMNEY+PLUGGING GAS PIPE, MAINTAIN BOILER; CORRECT VIOLATION+SUBMIT CERTIFICATE OF CORRECTION$1K due
ECB07/03/2023NOTED: AT TIME OF INSPECTION, OBSERVED THE WINDOWSILLS AND DECORATIVE STONE ABOVE THE LINTELS AT EXPOSURE 1 (FRONT) AND 4 (RIGHT) WITH EXCESSIVE SPALLING, CRACKS, AND MISSING MASONRY IN VARIOUS AREAS THROUGHOUT$25K due
HPD02/11/2023HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD02/11/2023§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL AND BUZZER INTERCOM SYSTEM FROM BUILDING ENTRANCE IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
ECB07/22/2022FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCE; NOTED: OBSERVED AT EXTERIOR FACADE CHIPPED/CRACK WINDOW SILLS AT VARIOUS LOCATION(FRONT & RIGHT SIDE) BETWEEN THE 2ND & 4TH FLOOR, MISSING PIECE OF STONE AB$12K due
DOB12/23/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB09/22/2020WORK W/O A PERMIT. NOTE:AT TIME OF INSPECTION OBSERVED RENOVATION WORKTHAT HAD BEGAN IN APTS 1 AND 6 BATHROOMS AND KITCHENS HAD BEEN REMOVED. CEILING AND SOME OF THE WALLS HAD BEEN SHEETROCKED AND TAPED. ON THE$2K due